NX Series Reader User Guide NX-M00C NX-M01C NX-M02C NX-M01CA NX-M02CA Master Box- No RM4 with connectors. Master Box- 1 X RM4 with connectors. Master Box- 2 X RM4 with connectors.
Allflex NX Series Operational Manual TABLE OF CONTENTS Regularity Notices and Conformity .....................................................................................................................................................3 Antenna Warning ..................................................................................................................................................................................4 Product Safety Notices ....................................................
Allflex NX Series Operational Manual REGULARITY NOTICES AND CONFORMITY Australia and New Zealand RMA This device has been tested and meets the Electromagnetic Compatibility requirements for CISPR 22 and Radio testing AS/AZS 4268 USA – FCC Information to the user (FCC Part 15.105) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Allflex NX Series Operational Manual ANTENNA WARNING This device has been designed to operate with the antennas listed below. The NX Series Readers are only approved with the detachable antennas below. In accordance with RSS-GEN Issue 2 June 2007 Section 7.1.4 and FCC Part 15.21, antennas not included in this list are strictly prohibited for use with this device.
Allflex NX Series Operational Manual 1.0 THE NX SERIES The NX Reader series is available in different configurations NX-R01 NX-R02 NX-M Model Description NX-R01 Reader Box – 1x RFM. No connectors. LED indicators for power, read, exciter and high noise. Reader Box – 2x RFM. No connectors. LED indicators for power, read, exciter and high noise. Reader Box – 1x RFM. Connectors for power and Rnet. LED indicators for power, read, exciter and high noise.
Allflex NX Series Operational Manual The NX Antenna series is available in different configurations NX-AP12060 NX-AP9045 NX-AW50 Model NX-AW30 NX-AW50 NX-AW100 NX-AW1500 NX-AW2000 NX-AW2500 NX-AW3000 NX-AP4030 NX-AP6040 NX-AP9045 NX-AP12060 NX-ANB805 Page 6 of 14 Description Antenna Wand 30cm Antenna Wand 50cm Antenna Wand 100cm Antenna Wand 150cm Antenna Wand 200cm Antenna Wand 250cm Antenna Wand 300cm Antenna Panel 40x 30cm Antenna Panel 60x 40cm Antenna Panel 90x 45cm Antenna Panel 120x 60cm Anten
Allflex NX Series Operational Manual 2.0 PREPARATION FOR USE When you have mounted your Allflex Reader, and you are ready to use it, please ensure the following steps are closely followed: When inserting or attaching a new electronic RFID device into or on an animal, keep all other electronic RFID devices a minimum of 3 meters away from the Allflex Reader. This will ensure you only read the device you are inserting or attaching. Keep computers a minimum of 3 meters away from the Allflex Reader.
Allflex NX Series Operational Manual 4.0 CONNECTIONS There are two type of reader connection configurations, NX-M and NX-R. 1. NX-M Master Reader shown below as a NX-M01CA 2. NX-R Slave Reader shown as a NX-R01CA Note: There are several variants of the NX-M and NX-R which have different connector configurations. NX-M01CA USB Stick USB PC • • • • • • • I/O Serial R-NET 12vdc Power Antenna USB Stick – Is used for downloading tags from reader and doing software updates.
Allflex NX Series Operational Manual 5.0 POWER Power requirement. Use the 12vdc power cable supplied and connect to a 12vdc power source. An external 12-volt battery can be used, or a regulated linear power supply. DO NOT USE A SWITCH MODE POWER SUPPLY as some switch mode power supplies can interfere with the performance of the system. Voltage range is 12vdc to 14vdc.
Allflex NX Series Operational Manual F list all files G download all files G 'file' download a file time Gets the systems current time time_set Set the systems current time using the following format:dd-MM-yyyy hh:mm:ss dfl list all deleted files dfli Deleted files info list dfg 'file' Download a deleted file dfga Download all deleted files dfr 'file' Restore a deleted file dfra Restore all deleted files factory_reset Factory Reset relay_set '1,2,3,4(relay number)' '1(on) or 0(off)'
Allflex NX Series Operational Manual 6.1 Bluetooth If Bluetooth is enabled, you can access it's settings through the home screen by pressing the Bluetooth Icon on the right side of the screen. If disabled, you will need to access Bluetooth settings through the menu. Menu --> System Setup --> Comms --> Bluetooth. Once in Bluetooth settings press "Enable" top right of the screen. 6.
Allflex NX Series Operational Manual 7.0 RM4/SYNC MODULE DIAGNOSTICS Open RM4/Sync module diagnostics, image below, through Menu --> Tools --> Noise. 7.1 Locating RM4s By pressing the ID value for a RM4, you will send a find command to the associated device. This will cause a green LED to flash allowing you to see which devices are where in your system. Press the ID value again to stop the flashing. 7.
Allflex NX Series Operational Manual 8.0 TAG MANAGER Tag Manager is an all in one Tag Management program for Allflex Readers. The software supports tag session reading, writing and deleting. Some readers are also configurable through the software. To get Tag Manager vist http://www.aleis.com/aleis-software-user-guides/tag-manager. Once downloaded be sure to check for updates through Help, Check for updates. To read more about Tag Manager, a user guide can also be found in the link provided above. 9.
Allflex NX Series Operational Manual 14.0 NX SERIES READER SPECIFIACTIONS General Frequency: RFID Compatibility: User Interface: RS-232 Port: RFID Code output: Antenna Tuning: User Options: Battery Power: 134.2Khz, Bit 1 124.2Khz +/-2Khz, Bit 0 134.2Khz +/-1.5khz ISO 11784 &11785 HDX and FDX-B RS-232 Serial Port. Bluetooth and WiFi NX-M only. 9600bps, 8 Data Bits, No Parity, 1 Stop Bit.