Installation Guide

PG 25
ZERO-CLEARANCE FIREPLACE INSTALLATIONS
1. Manufacturer's Instructions: Carefully read and comply with the
manufacturer’s installation instructions for your fireplace. Be sure that AllFuel
HST is approved for use with your appliance.
2. Anchor Plate: Attach an Anchor Plate to the fireplace top with (4) ⅝” sheet metal
screws (Fig 27). Check with the appliance manufacturer about the use of high
temperature sealants.
3. Chimney sections: Attach a Chimney Section to the Anchor Plate by twist
locking clockwise.
4. Completion: Install the remainder of the chimney as instructed for a standard
Ceiling Supported Installation, Steps 4 through 10 (page 8-11) (using a Firestop
Radiation Shield in the 1st floor ceiling instead of the Support Box). Always
maintain at least 2 inches of clearance to combustibles, and enclose the chimney
where it passes through occupied areas.
AllFuel HST Inc www.allfuelhst.com Toll Free: (833) 326-8368