Product Brochure
21
www.allfuelhst.com
The attic insulation shield is used in through the ceiling installations
to prevent insulation and other debris from contacting the chimney
in the attic.
The attic insulation shield is placed above the Ceiling Support Box on
top of the framing of the ceiling where the chimney passes through
the attic. If the chimney is fully enclosed in a chase the attic insulation
shield is not required. Includes 1 Storm Collar.
Attic Insulation Shield for 8" Inner
Diameter Chimney Pipe
The firestop radiation shield is used when passing through a second story
floor, and at every floor above, to protect the floor joists where the chimney
passes through the floor.
The firestop radiation shield is installed on the underside of the ceiling/floor
framing, with the cylindrical "tube" pointing upward.
Example: in a 3 story home where the appliance is on the ground floor the
support box is installed in the 1st floor ceiling, a radiation shield is installed at
the 2nd and 3rd floor ceilings (where the chimney enters the attic space).
A firestop radiation shield is not installed where the chimney penetrates the
roof.
Firestop Radiation Shield for 8" Inner
Diameter Chimney Pipe
The roof radiation shield provides protection for the rafters where
the chimney passes through the roof.
Use the roof radiation shield if the chimney is enclosed in a chase
immediately prior to passing through the roof. If the chimney is not
fully enclosed before passing through the roof the roof radiation
shield is not required.
Roof Radiation Shield for 8" Inner
Diameter Chimney Pipe
BL.EV.RB-SHT8AIS
BL.EV.RB-SHT8FRS
BL.EV.RB-SHT8RRS