Tumble Dryer Installation/Operation Maintenance Manual

© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
22 M414545
Figure 3
Solvent gases and vapors from dry
cleaning machines create acids when
drawn through the heater of a drying
tumbler. These acids are corrosive to the
drying tumbler as well as to the laundry
load being dried. Be sure make-up air is
free of solvent gases and vapors.
If the dry cleaning machines are in the
same area as the tumbler, then the
tumbler make-up air must come from a
source free of solvent gases and vapors.
W058
WARNING
To reduce the risk of fire and
accumulation of combustible gases, DO
NOT exhaust tumbler air into a window
well, gas vent, chimney or enclosed,
unventilated area such as an attic wall,
ceiling, crawl space under a building, or
concealed space of a building.
W059
WARNING
T108IE3C
NOTE: Inside of duct shall be
smooth. Do not use sheet
metal screws to join sections.
NOTE: Do not install wire
mesh or screen in this
opening as lint will build up
and prevent proper discharge
of air from drying tumblers.
ROOF 30" (76.2 CM)
ROOF 30" (76.2 cm)
CEILING
WALL
36 INCHES
(91.4 cm)
RECOMMENDED
SERVICE AREA
24 INCHES
(61.0 cm)
MINIMUM
PARTITION OR
BULKHEAD
REMOVABLE STRIP OF PANEL IN FRAMING WALL
TO PERMIT REMOVAL OF DRYING TUMBLER
FROM FRAMING WALL
CONSULT YOUR LOCAL BUILDING
CODE FOR REGULATIONS WHICH
MAY ALSO APPLY
T075IE3A
FOR BEST PERFORMANCE
provide an individual exhaust
duct for each drying tumbler.
Do not install a hot water heater
in room containing drying
tumblers. It is better to
have the water heater in
a separate room with a
separate air inlet.
T108IE3A
TWO
DRYING
TUMBLERS
THREE
DRYING
TUMBLERS
ONE
DRYING
TUMBLER