Specifications

Steam Requirements
43
70260301
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
120 Pound Tumblers
Figure 17
TMB2014N
NOTE: Refer to Table 10 for sizing of steam lines. Piping must also be sized accordingly for length of runs and
number of elbows.
1 Supply 8 18 in. (457 mm) Drop
2 12 in. (305 mm) Riser 9 Solenoid Valve (Supplied with machine)
3 Shut-Off Valve 10 Steam Bonnet
4 Condensate Return Line from Supply Line 11 Flexible Line
5 Return 12 Union
6 Check Valve 13 Trap with Built-In Strainer
7 Vacuum Breaker (Optional)
TMB2014N
2
12
6
3
5
1
13
10
9
8
6
7
4
11
Model
Steam Pressure
PSI (bar)
Minimum Pipe Diameter
Steam Trap Size *
(Pounds Condensate/Hour)
120S
120-125 (8.3-8.6) 1 in. NPT 345
60-120 (4.1-8.3) 1 in. NPT 345
35-60 (2.4-4.1) 1-1/4 in. NPT 345
*Based on maximum psi.
Table 10