Service manual

M411433 17
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
10. HEATING ELEMENT OR BURNER DOES NOT SHUT-OFF
11. CLOTHES DO NOT DRY
12. TUMBLER OVERHEATING
POSSIBLE CAUSE TO CORRECT
Gas Models:
Impurities on gas valve seat, preventing valve from
closing.
Replace gas valve.
Inoperative drying timer, relay or contactor. Replace timer, relay or contactor.
Incorrect wiring. Refer to wiring diagram located on back of tumbler or in
literature packet.
POSSIBLE CAUSE TO CORRECT
Heat source inoperative. Refer to Paragraph 5.
Too much water in articles being dried. Remove excess water.
Clothes load too large. Remove part of load.
Improper or inadequate exhaust system. Refer to Installation Manual (supplied with tumbler) for
exhaust requirements.
Heat source shuts-off prematurely. Refer to Paragraph 8.
Drying timer improperly set. Set selector for higher setting.
Incorrect voltage. Refer to Installation Manual (supplied with tumbler) for
electrical requirements.
Inadequate make-up air. Refer to Installation Manual (supplied with tumbler) for
make-up air requirements.
POSSIBLE CAUSE TO CORRECT
Gas Models: Incorrect main burner orifices. Replace orifices.
Gas Models: Gas pressure too high. Gas pressure must be as specified on serial plate.
Inadequate make-up air. Refer to Installation Manual (supplied with tumbler) for
make-up air requirements.
Lint accumulation. Remove lint.
Restricted or inadequate exhaust system. Remove obstruction or lint build-up from exhaust
ductwork. Refer to the Installation Manual (supplied
with tumbler) for exhaust system requirements.
Inoperative thermostat. Replace thermostat.