Service manual

M411433 37
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
38. THERMISTOR
(Electronic Control Models Only)
Refer to Figure 13.
a. Unlock and remove the lint panel.
b. Remove the two screws holding the perforated
cover to the thermistor bracket.
c. Disconnect the wires from the back of the
thermistor.
d. Remove the two screws holding the thermistor
to the bracket.
OM Models: Unthread thermistor from
bracket.
NOTE: Refer to the wiring diagram when
reconnecting the wires to the thermistor.
Figure 13
THERMISTOR
T093SE3C
THERMISTOR
WIRES
SCREW
PERFORATED
COVER
LINT
PANEL
T345P
OM Models