Specifications

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation/Operation Supplement
29
C002882
Provisions for 50 Hz Installations
If machine is to be installed on a 50 Hz power system,
adjust control transformer taps as described in
Installation manual. Then change drain valve wiring
as follows:
1. Disconnect power from machine. Follow lock-
out/tag-out procedures.
2. Remove lower rear panel to acess drain valves.
3. Snap black plastic cover off of each drain valve
motor by locating and squeezing two tabs on
each cover.
4. On each drain valve motor there are three
terminals (labeled 60 Hz, 50 Hz and N). Locate
these terminals.
5. On each drain valve motor, move wire from 60
Hz tap to 50 Hz tap. There should be wires on 50
Hz terminal and N terminal.
6. Reinstall black plastic motor covers.
7. Reinstall rear panel.
8. Reconnect power to machine.
NOTE: If proper tap on drain valve motor is not
selected it will run hot and will be damaged.
PHM695N
1 Cover
Figure 13
50Hz
60Hz
N
1