Operation/Programming/Maintenance Drying Tumblers Stacked 30 Pound Capacity Stacked 45 Pound Capacity Starting Serial No. 0602004144 Refer to Page 3 for Model Numbers Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) www.comlaundry.com Part No.
Installation must conform with local codes or in the absence of local codes with: In the U.S.A., installation must conform to the latest edition of the American National Standard Z223.1/ NFPA 54 “National Fuel Gas Code” and Standard ANSI/NFPA 70 “National Electric Code.” In Canada, installation must comply with Standards CSA-B149.1 or Natural Gas and Propane Code CSA C22.1, latest edition, Canadian Electric Code, Part I.
Table of Contents Introduction......................................................................................... Model Identification ............................................................................. Customer Service.................................................................................. Serial Plate Location............................................................................. Wiring Diagram ...............................................................................
Introduction Model Identification Information in this manual is applicable to these models: Gas T30 CHD30STG2-CAT30L CHD30STG2-CAT30N CHD30STG2-CTT30L CHD30STG2-CTT30N CHD30STG2-CUT30L CHD30STG2-CUT30N DRST30G2-BAT30L DRST30G2-BAT30N DRST30G2-BTT30L DRST30G2-BTT30N DRST30G2-BUT30L DRST30G2-BUT30N IPD30STG2-ITT30L IPD30STG2-ITT30N T45 IPD45STG2-ITT45L IPD45STG2-ITT45N Steam CHD30STS2-CTT30S CHD30STS2-CUT30S DRST30S2-BTT30S DRST30S2-BUT30S IPD30STS2-ITT30S Electric CHD30STE2-CTT30E CHD30STE2-CUT30E DRST
Introduction Customer Service Wiring Diagram If literature or replacement parts are required, contact the source from which the machine was purchased or contact Alliance Laundry Systems at (920) 748-3950 for the name and address of the nearest authorized parts distributor. The wiring diagram is located in the upper junction or upper contactor box. The wiring diagram part number is located in the lower portion of the electrical data on the serial plate. For technical assistance, call (920) 748-3121.
Safety Information Explanation of Safety Messages Precautionary statements (“DANGER,” “WARNING,” and “CAUTION”), followed by specific instructions, are found in this manual and on machine decals. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine. DANGER Indicates an imminently hazardous situation that, if not avoided, will cause severe personal injury or death.
Safety Information 14. The interior of the tumbler and the exhaust duct should be cleaned periodically by qualified service personnel. Important Safety Instructions Save These Instructions WARNING Hazardous Voltage. Can cause shock, burn or cause death. Allow machine power to remain off for two minutes prior to working in and around AC inverter drive. W359 1. Read all instructions before using the tumbler. 2. Refer to the GROUNDING INSTRUCTIONS for the proper grounding of the tumbler. 3.
Safety Information 23. Remove laundry immediately after tumbler stops. 24. Always read and follow manufacturer’s instructions on packages of laundry and cleaning aids. Heed all warnings or precautions. To reduce the risk of poisoning or chemical burns, keep them out of reach of children at all times (preferably in a locked cabinet). 25. Do not tumble fiberglass curtains and draperies unless the label says it can be done.
Operating Instructions WARNING To reduce the risk of fire: • DO NOT DRY articles containing foam rubber or similarly textured rubberlike materials. • DO NOT DRY plastics, anything containing wax or chemicals such as mops and cleaning cloths, or anything dry-cleaned at home with a dry-cleaning solvent. • DO NOT TUMBLE fiberglass curtains and draperies unless the label says it can be done. If they are dried, wipe out the cylinder with a damp cloth to remove particles of fiberglass.
Operating Instructions Control Instructions TMB2119N Figure 3 Dual Digital Timer Control QT Control Suffix 1. Select HIGH, MED, LOW or NO HEAT by turning the temperature knob. 2. Set the HEAT TIME for the number of minutes (from 0-60) desired. 3. Set the COOL DOWN TIME for the number of minutes (from 0-15) desired. 4. Press and release START button to start tumbler. Display will show minutes remaining before end of cycle. NOTE: One touch drying is available for repetitive loads.
Operating Instructions Error Codes WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the tumbler before servicing. • Close gas shut-off valve to gas tumbler before servicing. • Close steam valve to steam tumbler before servicing. • Never start the tumbler with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.
Operating Instructions 25 C Figure 4 Single Drop Control Preliminary Control Information SD and SX Control Suffixes Power-Up Mode 1. Select HIGH, MED, LOW or NO HEAT by turning the temperature knob. 2. Insert the coin(s) in the coin slot. 3. Press START button to start tumbler. IMPORTANT: To stop the tumbler at any time during the cycle, OPEN DOOR. To restart the tumbler, CLOSE door and press START button. NOTE: If display show an error code, refer to Error Codes section. 4.
Operating Instructions Run Mode In Run Mode, the control is running a cycle. The IN USE LED is lit. Door Open Mode If the control receives a coin drop pulse during cool down the IN USE LED will flash briefly to indicate the coin input, the machine will exit cool down and it will start heating. The cycle time will be equal to the programmed dry time In Door Open Mode, the control turns off the heater and motor when the door is opened during a run cycle.
Operating Instructions Ignition Control Operation Power Up After 24 VAC is applied to the ignition control pins 24V and GND, the Diagnostic LED on the ignition control will turn orange/yellow. If a fault is detected the ignition control will enter Lockout Mode. If no faults are detected, the Diagnostic LED will turn Green and the ignition control will enter Standby Mode. Standby Mode While in Standby Mode, the ignition control will continually monitor the system for faults.
Operating Instructions System Tests Flame Probe Tests The following system tests are performed during normal operation. System tests are performed at a minimum of every 24 hours. Unexpected Presence of Flame Low Voltage Detection If the voltage between terminals TH and GND on the control is below 18.75VAC +/- 0.75VAC for more than 3 seconds the ignition control will turn off the gas valve and will not attempt to spark. The Diagnostic LED will display Error Code 5.
Maintenance WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the tumbler before servicing. • Close gas shut-off valve to gas tumbler before servicing. • Close steam valve to steam tumbler before servicing. • Never start the tumbler with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded. W002 Daily 1.
Maintenance WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the tumbler before servicing. • Close gas shut-off valve to gas tumbler before servicing. • Close steam valve to steam tumbler before servicing. • Never start the tumbler with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.
Maintenance WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the tumbler before servicing. • Close gas shut-off valve to gas tumbler before servicing. • Close steam valve to steam tumbler before servicing. • Never start the tumbler with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded. W002 Monthly Bi-Annually 1.
Maintenance WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the tumbler before servicing. • Close gas shut-off valve to gas tumbler before servicing. • Close steam valve to steam tumbler before servicing. • Never start the tumbler with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.
Maintenance WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the tumbler before servicing. • Close gas shut-off valve to gas tumbler before servicing. • Close steam valve to steam tumbler before servicing. • Never start the tumbler with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.
Before You Call for Service Won’t Start Won’t Heat Clothes Not Dry Possible Reason – Corrective Actions • Insert correct coin(s) or valid card if applicable. • Close the loading door tightly. • Close lint panel tightly. • Press the START pad/button. • Be sure power is supplied to the machine. • Check the main fuse and circuit breaker. • Check fuses located in the machine. • Insufficient airflow. • Gas shut-off valve in OFF position.