Service manual

505872 11
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
6. HEATING ELEMENT DOES NOT HEAT AND BURNER DOES NOT IGNITE
7. IGNITER DOES NOT GLOW (Gas Supply Sufficient) – GAS MODELS
8. BURNER IGNITES AND GOES OUT REPEATEDLY – GAS MODELS
POSSIBLE CAUSE TO CORRECT
Improper or inadequate exhaust system. Refer to Installation Instructions (supplied with dryer)
for exhaust requirements.
Blown fuse or tripped circuit breaker. Check fuses or circuit breakers. (Electric models have two
fuses.)
FABRIC switch set at FLUFF, or inoperative. Reset switch, or test switch and replace if inoperative.
Timer improperly set—nonmetered models. Reset timer.
Inoperative limit thermostat. Test thermostat and replace if inoperative.
Electric Models: Inoperative heating element. Replace element.
Gas Models: Insufficient gas supply. Open partially closed gas shut-off valve, or correct low
gas pressure.
Inoperative drive motor switch. Test switch and replace if inoperative.
Gas Models: Inoperative gas valve coils. Test coils and replace if inoperative.
Gas Models: Inoperative igniter. Test igniter and replace if inoperative.
Gas Models: Inoperative sensor. Test sensor and replace if inoperative.
Electric Models: Inoperative thermal fuse. Test thermal fuse and replace if inoperative.
Inoperative cycling thermostat. Test thermostat and replace if inoperative.
Inoperative timer—nonmetered models. Test timer and replace if inoperative.
Inoperative accumulator—metered models. Test accumulator and replace if inoperative.
Broken, loose, or incorrect wiring. Refer to appropriate wiring diagram.
POSSIBLE CAUSE TO CORRECT
No power to power leads on valve. Check electrical circuit, Paragraph 45.
Sensor failed with contacts open. Replace sensor.
Igniter broken or open. Replace igniter.
POSSIBLE CAUSE TO CORRECT
Burner heat not holding sensor contacts open. Replace sensor.
Insufficient gas supply. Check gas supply and pressure.
Make sure gas shut-off valve is open.