Service manual
28 505872
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
23. GRAPHICS PANEL
Refer to Figure 7
a. Card Reader Models, remove panel lock (if
present).
NOTE: Several turns of the key may be required to
remove panel lock.
b. Remove two control panel attaching screws and
lift assembly off cabinet top.
c. Remove knurled nut holding temperature
switchtopanel.
d. Remove hex nut from PUSH-TO-START
switch.
e. Card Reader Models without panel lock,
remove lock plug.
f. Remove graphics panel.
24. RELAYS (Card Reader Models)
Refer to Figure 7
a. Remove panel lock, (if present).
NOTE: Several turns of the key may be required to
remove panel lock.
b. Remove two control panel attaching screws and
lift assembly off cabinet top.
c. Disconnect wires from relay.
NOTE: Refer to appropriate wiring diagram when
rewiring relays.
d. Remove two screws holding timer mounting
bracket assembly to cabinet top.
e. Remove two screws holding relay to mounting
bracket assembly.
To Test Temperature Switch
1. Disconnect all wires from temperature switch.
NOTE: Refer to appropriate wiring diagram
when rewiring switch.
2. Models equipped with No. 56576
Temperature Switch – Set test meter to read
OHMS and apply meter leads to terminals:
3. Models equipped with No. 61512
Temperature Switch – Set test meter to read
OHMS and apply meter leads to terminals:
Meter should give “no reading” from L1 to 1
and from L1 to 2 in FLUFF.
(1) L1 and C
L1 and 2
L2 and 2
2andC
}
“zero” reading in NORMAL
(2) L2 and C
2 AND C
}
“zero” reading in
PERMANENT PRESS
(3) L1 and 2
2and1
}
“zero” reading in
DELICATE
(1) L1 and 2
}
“zero” reading in NORMAL
(2) L1 and 2
}
“zero” reading in
PERMANENT PRESS
(3) L1 and 1
L1 and 2
}
“zero” reading in DELICATE