Service manual

30 505872
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
25. TIMER
a. Card Reader Models with timer mounted
behind control panel:
(1) Refer to Figure 7 for timer removal.
(2) Card Reader Models, remove panel lock
(if present).
(3) Several turns of the key may be required
to remove panel lock.Remove two control
panel attaching screws and lift assembly
off cabinet top.
(4) Remove two screws holding timer to timer
bracket.
(5) Remove ground screw holding ground
wire to timer.
(6) Disconnect wires from timer.
NOTE: Refer to appropriate wiring diagram when
rewiring timer.
b. Nonmetered models:
(1) Refer to Figure 8 for timer removal.
(2) Loosen setscrew holding timer knob to
timer shaft and remove knob.
(3) Remove four screws and lockwasher
holding timer and plate to timer case.
Figure 8
CONTROL
HOOD
DR078-SV-1
LOCKWASHER
SETSCREW
LOCKWASHER
NUT
LOCKWASHER
LOCKWASHER
NUT
LOCKWASHER
CAPSCREW
CAPSCREW
SCREW
SCREW
WASHER
TIMER
PLATE
CABINET
TOP
INSTRUCTION
STICKER
TIMER
CASE
TIMER
ASSEMBLY
LOCKNUT
GROUND WIRE
(GREEN)
TIMER
SPACER
RIVET
TIMER KNOB
ASSEMBLY