Service manual
44 505872
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
43. DOOR HINGE
a. Open loading door and remove four screws
holding door assembly to hinges. Refer to
Figure 16.
b. Remove two screws from bottom edge of front
panel. Refer to Figure 13.
c. Swing bottom of panel away from dryer to
disengage hold-down clips and guide lugs from
cabinet top. Refer to Figure 13.
d. Disconnect wires from door switch. Refer to
Figure 13.
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
e. Remove four screws and locknuts holding
hinges to front panel. Refer to Figure 13.
44. HOLD-DOWN CLIPS AND GUIDE LUGS
Refer to Figure 13
a. Remove two screws from bottom edge of front
panel.
b. Swing bottom of panel away from dryer to
disengage hold-down clips and guide lugs from
cabinet top.
c. Disconnect wires from door switch. Refer to
Figure 18.
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
d. Compress hold-down clips and remove from
slot in top flange of front panel.
e. Remove four screws holding four guide lugs to
front panel. Refer to Figure 13.
Figure 19
DR036-SV-1
SCREW
BURNER
HOUSING
BURNER TUBE
SCREW
DISCONNECT
BLOCK
NIPPLE
UNION
NUT
VALVE
TAB
SENSOR
INLET
TUBE
HEAT
SHROUD
SENSOR
ATTACHING
SCREW