Installation manual
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
7
F232139
Programming
P and S-Series Microcomputers
Entering Program Mode
1. Unlock and raise top cover.
2. Remove control module cover.
3. Locate the Run/Program Mode switch near
center of computer board inside control module.
Refer to Figure 1.
Figure 1
4. Flip switch to up position to enter Program
Mode. Display will show current temperature of
sump.
Programming Setup Options
NOTE: Selection of degrees Fahrenheit or Celsius
is only option for setup.
1. Press Stop (*) key to enter Setup Mode while
display is showing temperature in sump.
2. Use Up or Down (arrow) key to change selected
option. Press Start (#) key to accept selected
option, either “FAr” or “CEL”.
3. Press Stop (*) key to exit Setup Mode.
Programming a Cycle
1. Press Up (arrow) key until computer display
shows segment to be edited. Press Start (#) key.
2. Use Up or Down (arrow) key to select desired
segment time. Refer to Table 1. Set value to zero
to skip segment. Press Start (#) key.
B152R
1 Run/Program Mode Switch
2 Computer Board
1
2
Time and Temperature Parameters
Segment Minimum Maximum
PreWash 1 minute 30 minutes
Wash 2 minutes 20 minutes
Fill 1 2 minutes 15 minutes
Fill 2 2 minutes 15 minutes
Fill 3 2 minutes 15 minutes
Fill 4 2 minutes 15 minutes
Intermediate Spin 30 seconds 120 seconds
Final Spin 1 minute 10 minutes
Temperature 75°F (25°C) 200°F (93°C)
Table 1