Cabinet Hardmount Design 2 and 3 Models Refer to Page 8 for Model Identification Installation/Operation/Maintenance Washer-Extractors CHM1782C_SVG Original Instructions Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) www.alliancelaundry.com Part No.
Table of Contents Safety Information..................................................................................5 Explanation of Safety Messages....................................................................... 5 Important Safety Instructions........................................................................... 5 Safety Decals................................................................................................. 6 Operator Safety.....................................................
Input Voltage Requirements....................................................................... 51 Circuit Breakers and Quick Disconnects......................................................... 52 Connection Specifications..............................................................................52 Single-Phase Connections.......................................................................... 52 Three-Phase Connections...........................................................................
Safety Information Safety Information Explanation of Safety Messages • Precautionary statements [“DANGER,” “WARNING,” and “CAUTION”], followed by specific instructions, are found in this manual and on machine decals. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine. • DANGER • Indicates an imminently hazardous situation that, if not avoided, will cause severe personal injury or death.
Safety Information warnings or precautions. To reduce the risk of poisoning or chemical burns, keep them out of the reach of children at all times [preferably in a locked cabinet]. Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product. Always follow the fabric care instructions supplied by the textile manufacturer. Loading door MUST BE CLOSED any time the washer is to fill, tumble or spin.
Safety Information WARNING NEVER insert hands or objects into basket until it has completely stopped. Doing so could result in serious injury. SW012 The following maintenance checks must be performed daily: 1. Verify that all warning labels are present and legible, replace as necessary. 2. Check door interlock before starting operation of the machine: a. Attempt to start the machine with the door open. The machine should not start. b. Close the door without locking it and start the machine.
Introduction Introduction Model Identification Information in this manual is applicable to Design 2 models or later. Refer to the 12th position of the model number [e.g.
Introduction Model 30 POUND CCN030HNF HCU030GNF SCL030JEV SCN030JCF SCN030WYV SCU030WDV CCN030HNV HCN030KDV ICN030KNV SCL030WEV SCN030WEF SCU030WEV CCN030KNF HCN030KEF ICN030KXF SCL030WXF SCN030WEV SCU030WXV CCN030KNV HCN030KEV ICN030KYF SCL030WYV SCN030WLV SCU030WYV HCD030LDF HCN030KXF ICN030KYV SCN030GNF SCN030WYF SCZ030GNF HCD030LDV HCN030KYF SCD030JDF SCN030GNV SCU030GNF UCL030GNF HCL030GNF HCN030KYV SCD030LDF SCN030HNF SCU030GNV UCL030GNV HCL030HDF HCU030GNV
Introduction Model 40 POUND 10 CCN040HNF HCN040KCV SCB040HNV SCL040JCF SCN040LCV SCU040LEV CCN040HNV HCN040KDF SCB040JYV SCL040KNF SCN040LLF SCU040LLF CCN040KNF HCN040KDV SCB040JCF SCL040JCV SCN040LDF SCU040WEV CCN040KNV HCN040KEF SCB040JCV SCL040JDF SCN040LDV SCU040LXV HCB040HNF HCN040KEV SCB040JDF SCL040JEF SCN040LEF SCU040LYV HCB040HNV HCN040KXF SCB040JDV SCL040JEV SCN040LEV SCU040WCF HCB040KCF HCN040KYF SCB040JEF SCL040JXF SCU040HNF SCU040WCV HCB040KCV HCN04
Introduction Model 60 POUND CCN060HNF HCN060KEV SCL060JEF SCN060JXF SCU060JCF UCL060GNF CCN060HNV HCN060KDV ICN060KNV SCN060GNF SCN060WEF SCU060LYV CCN060KNF HCN060KEF ICN060KXF SCN060GNV SCN060WEV SCU060WCV CCN060KNV HCN060KXF ICN060KYF SCN060HNF SCN060WYF SCU060WEV HCD060LDF HCN060KYF ICN060KYV SCN060HNV SCN060WYV SCU060WXV HCL060GNF HCN060KYV SCD060JDF SCN060LDF SCU060GNF SCU060WYV HCL060GNV HCU060GNF SCD060LDF SCN060LEF SCU060GNV UCL060GNV HCL060HCF HCU060GNV
Introduction Model 80 POUND 100 POUND 12 CCN080HNF HCN080KDV ICN080KDF SCN080LYV SCU080JXV UCL080KNF CCN080HNV HCN080KEF ICN080KDV SCN080JYV SCU080JDF SCU080WXV HCD080LDF HCN080KEV ICN080KEF SCN080KNF SCU080JDV SCU080WYV HCD080LDV HCN080KYF ICN080KEV SCN080KNV SCU080JEF UCL080GNF HCL080GNF HCN080KYV ICN080KNF SCN080LCF SCU080JEV UCL080HNF HCL080HNF HCU080GNF ICN080KNV SCN080LCV SCU080JLF UCL080HNV HCL080HNV HCU080HCF ICN080KYF SCN080LDF SCU080JLV UCL080KNV HCL08
Introduction Model 125 POUND HCN125KYV SCU125KNV SCL125KNV UCL125HNV SCN125KNV UCL125KNV SCN125LYV UCU125HNV SCN125WYV UCU125KNV Customer Service Delivery Inspection Upon delivery, visually inspect crate, protective cover, and unit for any visible shipping damage. If signs of possible damage are evident, have the carrier note the condition on the shipping papers before the shipping receipt is signed, or advise the carrier of the condition as soon as it is discovered.
Specifications and Dimensions Specifications and Dimensions General Specifications Specification 20 30 40 60 80 100 125 Weight and Shipping Information Net weight, lbs. [kg] 335 [152] 460 [209] 550 [249] 695 [315] 1210 [549] 1260 [572] 2301 [1044] Standard shipping weight, lbs. [kg] 365 [166] 495 [225] 590 [268] 745 [338] 1260 [572] 1310 [594] 2384 [1081] Standard shipping volume, ft3 [m3] Design 1 and 2 26.5 [0.75] 35.8 [1.01] 43.9 [1.24] 57.3 [1.62] 81.3 [2.30] 87.3 [2.
Specifications and Dimensions Specification 20 Slat crate shipping dimensions [WxDxH], in. [mm] Design 1 and 2 32.5 x 36.8 x 49.8 [826 x 935 x 1240] Design 3 32.5 x 36.8 x 55 [826 x 935 x 1397] 30 40 60 80 100 125 36 x 41.3 x 55 [914 x 1049 x 1397] 37 x 45.9 x 55 [940 x 1166 x 1397] 42 x 49.9 x 64 [1067 x 1267 x 1626] 48.5 x 57.5 x 65.1 [1232 x 1461 x 1654] 48.5 x 61.5 x 65.1 [1232 x 1562 x 1654] 59 x 64.5 x 80 [1499 x 1638 x 2032] Wash Cylinder Information Cylinder diameter, in.
Specifications and Dimensions Specification 20 30 40 60 80 100 125 400 [101] 450 [113] 510 [129] 750 [189] 950 [239] 950 [239] 1200 [302] Number of motors in drive train 1 1 1 1 1 1 1 Drive motor power, hp [kW] * 2 [1.5] 2 [1.5] 3 [2.2] 5 [3.7] 5 [3.7] 7.5 [5.6] Gentle wash/reverse speed, RPM [G] 37 [0.4] 34 [0.4] 33 [0.4] 31 [0.4] 28 [0.4] 28 [0.4] 26 [0.4] Wash/reverse speed, RPM [G] 51 [0.8] 48 [0.8] 46 [0.8] 43 [0.8] 39 [0.8] 39 [0.8] 36 [0.
Specifications and Dimensions Specification 20 Number of steam inlets Steam required to raise bath water temperature 10°F [10°C], lbs. [kg] 30 40 60 80 100 125 ** ** 1 1 1 1 1 LOW .74 [0.34] .94 [0.43] 2.09 [0.94] 3.80 [1.63] 3.80 [1.72] 3.80 [1.72] 3.64 [1.65] MED 1.07 [0.49] 1.28 [0.58] 2.40 [1.09] 4.65 [2.11] 4.65 [2.11] 5.49 [2.49] 5.17 [2.35] HIGH 1.44 [0.65] 1.74 [0.79] 2.84 [1.29] 5.79 [2.63] 5.79 [2.63] 6.84 [3.10] 7.78 [3.52] .34 .41 .78 .98 1.34 1.
Specifications and Dimensions Specification 20 30 40 60 80 100 125 * For B, Q, and X-voltage models = 1 hp [.75 kW] and for N and P-voltage models = 2 hp [1.7 kW] ** 20 and 30 pound models can be prep for steam and a kit is available for conversion. N/A = Not Applicable Table 1 Machine Dimensions 20-60 Pound Capacity Machines K J I H G 3 F 4 1 Q 5 2 W L A B C V D R S 6 E M N O P T U CHM2393N_SVG 20-60 Pound Models 1. Supply Dispenser 2. Input Power Block Compartment 3.
Specifications and Dimensions Machine Capacity Dimensions - 20-60 Pound Models 20 20 [Design 1 and 2] [Design 3] 30 40 60 A 38.0 in. [965 mm] 39.0 in. [991 mm] 40.94 in. [1040 mm] 43.19 in. [1097 mm] 45.88 in. [11.65 mm] B 35.0 in. [889 mm] 36.0 in. [914 mm] 37.9 in. [963 mm] 40.2 in. [1021 mm] 42.8 in. [1087 mm] C 34.5 in. [876 mm] 35.5 in. [902 mm] 37.5 in. [953 mm] 39.7 in. [1008 mm] 42.4 in. [1077 mm] D 4.7 in. [119 mm] 4.7 in. [119 mm] 4.14 in. [105 mm] 4.51 in.
Specifications and Dimensions Machine Capacity Dimensions - 20-60 Pound Models 20 20 [Design 1 and 2] [Design 3] T 14.38 in. [365 mm] 14.38 in. [365 mm] U 26.0 in. [660 mm] V W 30 40 60 14 in. [356 mm] 14.56 in. [370 mm] 14.94 in. [379 mm] 26.0 in. [660 mm] 29.0 in. [737 mm] 30.63 in. [778 mm] 34.06 in. [865 mm] 42.0 in. [1067 mm] 43.0 in. [1092 mm] 45.0 in. [1143 mm] 47.2 in. [1199 mm] 49.89 in. [1267 mm] 1.5 in. [38 mm] 1.5 in. [38 mm] 1.5 in. [38 mm] 1.5 in. [38 mm] 1.5 in.
Specifications and Dimensions 80 and 100 Pound Capacity Machines M L K J I H 3 4 G 2 1 S 5 6 F AA 7 A B C Z N T D U 6 V O Y P E X Q W R CHM2394N_SVG 80 and 100 Pound Models 1. Supply Dispenser 2. Input Power Block Compartment 3. Auxiliary Hot Water Inlet 4. Auxiliary Cold Water Inlet 5. Cold Water Inlet 6. Hot Water Inlet 7. Vacuum Breaker 8. Drain Outlet Figure 3 Machine Capacity Dimensions - 80 and 100 Pound Models A 51.82 in. [1316 mm] O 1.4 in. [35 mm] B 50.3 in.
Specifications and Dimensions Machine Capacity Dimensions - 80 and 100 Pound Models D 6.4 in. [163 mm] R 80 48.6 in. [1234 mm] 100 52.6 in. [1336 mm] E 2.6 in. [66 mm] S 9.0 in. [229 mm] F 3.0 in. [76 mm] T 30.9 in. [785 mm] G 6.9 in. [175 mm] U 20.8 in. [528 mm] H 8.8 in. [224 mm] V 17.91 in. [455 mm] I 16.7 in. [424 mm] W 41.5 in. [1054 mm] J 18.2 in. [462 mm] X 26.2 in. [665 mm] K 21.7 in. [551 mm] Y 3.6 in. [91 mm] L 26.2 in. [665 mm] Z 56.2 in. [1427 mm] M 30.
Specifications and Dimensions 125 Pound Capacity Machines 4 5 6 7 8 F E 2 1 D Q I A R H M G N B C 9 J O P K L CHM2389N_SVG 125 Pound Models 1. Dry Chemical Dispenser [Optional on OPL Models] 2. Input Power Block Compartment 3. Fans 4. Valve Panel 5. Cold Water Inlet 6. Hot Water Inlet 7. Liquid Chemical Inlet 8. Steam Inlet [Optional] 9. Drain Outlet Figure 4 Machine Capacity Dimensions - 125 Pound Models A 63.04 in. [1601 mm] J 2.29 in. [58 mm] B 11.69 in. [297 mm] K 49.
Specifications and Dimensions Machine Capacity Dimensions - 125 Pound Models I 65.77 in. [1671 mm] R 70.47 in. [1790 mm] Table 4 Mounting Bolt Hole Locations – 20 and 30 Pound Models B D C E A G I H F J K L P M N O 1 Q 2 3 R CHM2395N_SVG 20 and 30 Pound Models [refer to Table 5 ] 1. Elevated Base Width 2. Front of Base 3. Machine Width Figure 5 Mounting Bolt Hole Locations – 20 and 30 Pound Models 20 30 A 2 in. [51 mm] 2 in. [51 mm] B 26.37 in. [670 mm ] 29.38 in.
Specifications and Dimensions Mounting Bolt Hole Locations – 20 and 30 Pound Models 20 30 C 20.88 in. [530 mm] 23.89 in. [607 mm] D 2.75 in. [70 mm] 2.75 in. [70 mm] E 0.18 in. [5 mm] 0.18 in. [5 mm] F 0.25 in. [6 mm] 0.25 in. [6 mm] G 0.64 in. [16 mm] 0.64 in. [16 mm] H 2.71 in. [69 mm] 2.37 in. [60 mm] I 2.15 in. [55 mm] 1.81 in. [46 mm] J 4.69 in. [119 mm] 4.69 in. [119 mm] K 0.19 in. [5 mm] 0.19 in. [5 mm] L 9.64 in. [245 mm] 10.5 in. [267 mm] M 23.94 in. [608 mm] 28.
Specifications and Dimensions Mounting Bolt Hole Locations - 40 and 60 Pound Models B D C E A F H G I K J O L M N 1 P 2 3 Q CHM2397N_SVG 40 and 60 Pound Models [refer to Table 6 ] 1. Elevated Base Width 2. Front of Base 3. Machine Width Figure 6 Mounting Bolt Hole Locations - 40 and 60 Pound Models 40 60 A 2 in. [51 mm] 2 in. [51 mm] B 30.88 in [784 mm ] 34.44 in. [875 mm] C 26 in. [660 mm] 30 in. [762 mm] D 2.44 in. [62 mm] 2.22 in. [56 mm] E 0.12 in. [3 mm] 0.12 in.
Specifications and Dimensions Mounting Bolt Hole Locations - 40 and 60 Pound Models 40 60 F 0.64 in. [16 mm] 0.64 in. [16 mm] G 2.37 in. [60 mm] 2.37 in. [60 mm] H 2 in. [51 mm] 1.75 in. [44 mm] I 4.75 in. [121 mm] 5.15 in. [131 mm] J 1.19 in. [30 mm] 1.25 in. [32 mm] K 12.5 in. [318 mm] 11.93 in. [303 mm] L 32.5 in. [826 mm] 36 in. [914 mm] M 33.54 in. [852 mm] 36.87 in. [936 mm] N 37.25 in. [946 mm] 40.5 in. [1029 mm] O 23.63 in. [600 mm] 27.5 in. [699 mm] P 30.88 in.
Specifications and Dimensions Mounting Bolt Hole Locations – 80 and 100 Pound Models A D E F B C N G A B B O A H P A B I B A Q J R K L A B B A M CHM2399N_SVG 80 and 100 Pound Models [refer to Table 7 ] Figure 7 NOTE: For single machine installations or two machines installed back to back, use the outside bolt holes marked “A”. For multiple machines installed side by side with minimum clearance, use the inside bolt holes marked “B”.
Specifications and Dimensions Mounting Bolt Hole Locations – 80 and 100 Pound Models 80 100 F 6.63 in. [164 mm] 6.63 in. [164 mm] G 3.3 in. [84 mm] 3.3 in. [84 mm] H 16 in. [406 mm] 16 in. [406 mm] I 35 in. [889 mm] 35 in. [889 mm] J 37.3 in. [947 mm] 37.3 in. [947 mm] K 42.2 in. [1073 mm] N/A L N/A 46.2 in. [1260 mm] M 1 in. [25 mm] 1 in. [25 mm] N 1.96 in. [50 mm] 1.96 in. [50 mm] O Outside 42.72 in. [1085 mm] 35.43 in. [900 mm] P Inside 52.86 in. [1342 mm] 47.16 in.
Specifications and Dimensions Mounting Bolt Hole Locations – 125 Pound Models A A B C E F D G H I J J A 1 E CHM2069N_SVG 125 Pound Models [refer to Table 8 ] Figure 8 Machine Capacity Dimensions - 125 Pound Models 125 A 0.75 in. [19 mm] B 46.5 in. [1181 mm] C 10 in. [254 mm] D 15 in. [381 mm] E 48 in. [1219 mm] 30 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No.
Specifications and Dimensions Machine Capacity Dimensions - 125 Pound Models 125 F 61.5 in. [1562 mm] G 55.47 in. [1409 mm] H 48.94 in. [1243 mm] I 15.25 in. [388 mm] J 23.25 in. [591 mm] Table 8 Floor Mounting Layout – 20-60 Pound Models 1 A 2 B C 4 3 C B 5 CHM2426N_SVG Dimensional Clearances - Single Machine Mount (refer to Table 9 ) 1. Wall 2. Rear of Base 3. Edge of Concrete Pad 4. Machine 1 5. Front of Base Figure 9 Part No.
Specifications and Dimensions Dimensional Clearances - Single Machine Mount - 20-60 Pound Models Specifications 20 30 40 60 A - Distance to wall [minimum] 24 in. [610 mm] 24 in. [610 mm] 24 in. [610 mm] 24 in. [610 mm] B - Distance of machine base to edge of pad [minimum] 3.44 in. [87 mm] 4 in. [102 mm] 3.99 in. [101 mm] 5.99 in. [152 mm] C - Distance of machine base to edge of pad [minimum] 2.52 in. [64 mm] 2.51 in. [64 mm] 2.81 in. [71 mm] 5.18 in.
Specifications and Dimensions Dimensional Clearances - Side-by-Side Mount - 20-60 Pound Models Specifications B 20 30 40 60 Mounted without bases [minimum] 5.14 in. [131 mm] 5.12 in. [130 mm] 4.63 in. [118 mm] 4.06 in. [103 mm] Mounted with bases [minimum] 5.5 in. [139 mm] 5.5 in. [139 mm] 4.88 in. [124 mm] 4.44 in. [112 mm] Table 10 1 B 2 3 5 A 3 4 1 B CHM2376N_SVG Dimensional Clearances - Back-to-Back Mount (refer to Table 11 ) 1. Front of Machine 2. Machine 2 3. Rear of Machine 4.
Specifications and Dimensions Dimensional Clearances - Back-to-Back Mount - 20-60 Pound Models Specifications 20 30 40 60 A [minimum] 28.3 in. [719 mm] 27.6 in. [702 mm] 28.0 in. [710 mm] 27.5 in. [699 mm] B [minimum] 5.26 in. [134 mm] 5.26 in. [134 mm] 6.19 in. [157 mm] 8.9 in. [226 mm] Table 11 Floor Mounting Layout – 80 and 100 Pound Models 1 A 2 B C 4 3 C B 5 CHM2427N_SVG Standard Mount for Single Machine [refer to Table 12 ] 1. Wall 2. Rear of Base 3. Edge of Concrete Pad 4.
Specifications and Dimensions Standard Mount for Single Machine - 80 and 100 Pound Models Specifications 80-100 B - Distance of machine base to edge of pad [minimum] 4.98 in. [126 mm] C - Distance of machine base to edge of pad [minimum] 8 in. [203 mm] Table 12 1 A 2 2 3 4 5 B 5 PHM819N_SVG Standard Mount Side-by-Side [refer to Table 13 ] 1. Wall 2. Rear of Base 3. Machine 1 4. Machine 2 5.
Specifications and Dimensions 1 A 2 2 3 4 5 B 5 PHM820N_SVG Close Mount Side-by-Side [refer to Table 14 ] 1. Wall 2. Rear of Base 3. Machine 1 4. Machine 2 5. Front of Base Figure 14 Close Mount Side-by-Side - 80 and 100 Pound Models Specifications 80-100 A - Distance to wall [minimum] 24 in. [610 mm] B - Adjacent unit bolt spacing [minimum] 10.38 in. [264 mm] Table 14 IMPORTANT: When close mounting, bolt machine using inside bolt holes.
Specifications and Dimensions 1 B 2 3 A 5 3 4 1 B PHM810N_SVG Back-to-Back Mount [refer to Table 15 ] 1. Front of Machine 2. Machine 2 3. Rear of Machine 4. Machine 1 5. Edge of Concrete Pad Figure 15 Back-to-Back Mount - 80 and 100 Pound Models Specifications 80-100 A [minimum] 33.3 in. [846 mm] B [minimum] 8 in. [203 mm] Table 15 Part No.
Installation Installation Pallet Jack Cover Plate Removal [80 and 100 Pound Models Only] Prior to installing an 80 and 100 pound machine, the optional pallet jack cover plate can be removed in preparation of re-installing to machine base frame after machine installation. 1. Locate cover plate on back panel. 2. Remove back panel. 3. Remove all hardware holding cover plate on back panel, refer to Figure 16 . DO NOT DISCARD HARDWARE. 4. Remove cover plate.
Installation Isolated Pad Installation This type of installation is NOT recommended. Installer MUST consult a Structural Engineer for concrete specifications and requirements for installations that will not be tied into adjacent foundations. IMPORTANT: The above instructions and recommendations are conservative specifications for a typical installation based on consultations with a structural engineer. Alliance Laundry Systems stands behind all installations meeting these specifications.
Installation Machine Foundation and Pad Installation Specification 20 30 40 60 80-100 125 Two machines, Side-by-side [WxD] 57.54 in. x 34.8 in. [1462 mm x 884 mm] 63.52 in. x 39.5 in. [1613 mm x 1003 mm] 67.38 in. x 43.5 in. [1711 mm x 1105 mm] 78.98 in. x 50.6 in. [2006 mm x 1285 mm] 99.5 in. x 49.2 in. [2527 mm x 1250 mm] 133 in. x 72 in. [3378 mm x 1828 mm] Two machines, Back-to-back [WxD] 31.4 in. x 88.63 in. [798 mm x 2251 mm] 34.4 in. x 98.37 in. [874 mm x 2499 mm] 36.5 in. x 115.
Installation Machine Installation 1 A 2 PHM814N_SVG Existing Floor (refer to Table 9) 1. Existing Floor with 3500 PSI (minimum) Concrete 2. Compacted Fill (minimum 6 in. [152 mm]) Figure 18 Existing Floor 20-30 (F and V-speed) Description A - Required Thickness of Existing Floor (minimum) 40-60 (Fspeed) 4 in. [102 mm] 4 in. [102 mm] 80-100 (F and Vspeed) 40-60 (Vspeed) 6 in. [152 mm] 9 in. [229 mm] 125 (Vspeed) 12 in.
Installation Elevated Pad 20-30 (F and V-speed) Description 40-60 (Fspeed) 80-100 (F and Vspeed) 40-60 (Vspeed) 125 (Vspeed) A - Hight of Elevated Pad Above Floor (maximum) 8 in. [203 mm] 8 in. [203 mm] 8 in. [203 mm] 8 in. [203 mm] 8 in. [203 mm] B - Distance Between Reinforcing Bars (maximum) 12 in. [305 mm] 12 in. [305 mm] 12 in. [305 mm] 12 in. [305 mm] 12 in. [305 mm] C - Length of Reinforcing Bar Extending into Existing Floor (minimum) 2.5 in. [64 mm] 2.5 in. [64 mm] 2.5 in.
Installation Tie-in to Existing Floor 20-30 (F and V-speed) Description 40-60 (Fspeed) 80-100 (F and Vspeed) 40-60 (Vspeed) 125 (Vspeed) A - Required Thickness of Existing Floor (minimum) 4 in. [102 mm] 4 in. [102 mm] 6 in. [152 mm] 6 in. [152 mm] 6 in. [152 mm] B - Total Depth of Foundation (minimum) 8 in. [203 mm] 8 in. [203 mm] 12 in. [305 mm] 15 in. [381 mm] 18 in. [457 mm] C - Distance Between Reinforcing Bars (minimum) 12 in. [305 mm] 12 in. [305 mm] 12 in. [305 mm] 12 in.
Installation NOTE: If installing a 20 through 60 pound model directly to finished floor, wait until grout is completely cured and skip to Step 18. If installing on elevated base frame, proceed to Step 14. 20-60 Pound Models 14. After the grout is completely cured, position the machine over the elevated base frame. 15. Align the mounting holes on the machine with the corresponding holes on the elevated base frame. c. Tighten the two middle nuts firmly. 18. Torque all the locknuts to 90 ± 9 ft.-lbs.
Installation B C 1 2 A 3 D 4 5 E PHM809N_SVG Cast-in-place Anchors [refer to Table 20 ] 1. Machine Frame Base 2. Grout 3. Anchor Bolt [minimum Grade 5 SAE rating] 4. Concrete 5. Edge of Pad Figure 22 Minimum Anchoring Specifications Specification 20-40 60 80-100 125 Number of Bolts 4 or 6* 6 6 10 A Bolt Length 6 in. [152 mm] 6 in. [152 mm] 8.75 in. [216 mm] 8 in. [203 mm] B Thread Extension 2.5 in. [64 mm] 2.5 in. [64 mm] 2.75 in. [64 mm] 2.5 in.
Installation Floor Load Data Specification 20 30 40 60 80 100 125 Static floor load, lbs. [kN] 420 [1.87] 570 [2.54] 700 [3.11] 940 [4.18] 1550 [6.89] 1670 [7.51] 2795 [12.43] Static pressure, lbs.-ft2 [kN-m2] 96 [4.60] 99 [4.74] 100 [4.79] 106 [5.08] 137 [6.56] 147 [7.04] 163 [7.80] Dynamic floor load, lbs. [kN] 420 [1.86] 630 [2.80] 840 [3.74] 1260 [5.61] 1680 [7.48] 1680 [7.48] 2814 [12.52] Dynamic floor pressure, lbs.-ft2 [kN-m2] 96 [4.60] 109 [5.22] 119 [5.
Installation 1 2 3 7 5 6 4 CHM2379N_SVG Drain Trough System 1. Rear of Machine 2. Drain Pipe 3. Steel Grate 4. Drain Trough 5. Strainer 6. Waste Line 7. 1 in. [25 mm] minimum gap Figure 23 4 5* 3 2 1 6 CHM2386N_SVG * Drain line must be vented to meet local plumbing codes. Direct Drain System 1. Drain Hose 2. Drain Valve 3. Drain Tee 4. Overflow Hose 5. Vent Pipe* 6.
Installation Drain Information 20 30 40 60 80 100 125 Drain connection size 2 in. [51 mm] 2 in. [51 mm] 3 in. [76 mm*] 3 in. [76 mm*] 3 in. [76 mm*] 3 in. [76 mm*] 3.5 in. [89 mm*] Overflow drain connection size 1.5 in. [457 mm] 1.5 in. [457 mm] 1.5 in. [457 mm] 1.5 in. [457 mm] 2.25 in. [686 mm] 2.25 in. [686 mm] 2.25 in.
Installation Water Connection Requirements Cabinet Hardmount Water Supply Information WARNING Description To prevent personal injury, avoid contact with inlet water temperatures higher than 125° Fahrenheit [51° Celsius] and hot surfaces. W748 Model Inlet flow capacity per inlet, gal/min at 85 psi [l/min at 5.5 bar] The maximum water inlet temperature for vended models is 125°F [51°C] and the recommended maximum water inlet temperature for on-premises models is 150°F [66°C].
Installation Alliance Laundry Systems, LLC ranges of front loading commercial clothes washing machines have solenoid valves at the inlets. The water supply to the washing machines is supplied with an AB air gap between the soap tray and the drum. Minimum and maximum working pressure 1.4 bar and 8.3 bar. The machines are supplied with approved inlet hoses with a maximum inlet dimension of 0.50 inch [15 mm] [ID].
Installation Machines are equipped with an AC inverter drives requiring a clean power supply, free from voltage spikes and surges. Use voltage monitor to check incoming power. 1 Input Power Conditioning The drive is suitable for direct connection to input power within the rated voltage of the drive. Listed in Input Power Condition are certain input power conditions which may cause component damage or reduction in product life.
Installation DANGER 2 1 Electrical shock hazard will result in death or serious injury. Disconnect electric power and wait five (5) minutes before servicing. W810 4 3 DANGER Hazardous Rotation Speed. Will cause serious injury when controlling AC inverter drive with a parameter unit, safety features are bypassed allowing basket to rotate at high speeds with the door open. Place large sign on front of machine to warn people of imminent danger.
Installation WARNING 2 Electrically heated machines DO NOT require dual power sources. Do not connect customer power or customer load to the Internal Load Distribution terminal block. Refer to the machine electrical schematic for details. W759 2 3 CHASIS 1 TB1 SERVICE GROUND CHM2381N_SVG Machines without Electric Heat 1. Grounding Lug: Connect to proven earth ground 2. Customer Input Power Terminals Figure 31 Machines can be converted for lower voltage operation and/or 50 Hz operation.
Installation 20 Pound Capacity Models Voltage Designation Code Q Voltage Standard 220–240 Specifications Cycle 50/60 Phase 3 Wire 3 Electric Heat N P Standard Full Load Amps Circuit Breaker AWG mm2 3 15 14 2.5 21 30 10 6.0 440–480 50/60 3 3 2 15 14 2.5 380–415 50/60 3 3 2 15 14 2.5 13 15 14 2.5 Electric Heat NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Installation 30 Pound Capacity Models Voltage Designation Code P Voltage Standard 380–415 Specifications Cycle 50/60 Phase 3 Full Load Amps Wire 3 Electric Heat Circuit Breaker AWG mm2 3 15 14 2.5 13 15 14 2.5 NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Installation 40 Pound Capacity Models Voltage Designation Code Voltage Specifications Cycle Phase Full Load Amps Wire Circuit Breaker AWG mm2 NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310. Table 29 60 Pound Capacity Models Voltage Designation Code Voltage Specifications Cycle Phase Full Load Amps Wire Circuit Breaker AWG mm2 F and V-Speed Models [unless otherwise noted] X [F-speed] 220–240 50/60 1/3 2/3 9/6 15 14 2.
Installation 80 Pound Capacity Models Voltage Designation Code Voltage Specifications Cycle Phase Full Load Amps Wire Circuit Breaker AWG mm2 F-Speed Models X Q Standard 220–240 50/60 1/3 2/3 12/8 15 14 2.5 220–240 50/60 3 3 8 15 14 2.5 72 80 4 25.0 5 15 14 2.5 37 40 8 10.0 5 15 14 2.5 33 40 8 10.
Installation 80 Pound Capacity Models Voltage Designation Code Voltage Specifications Cycle Phase Full Load Amps Wire Circuit Breaker AWG mm2 NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310. Table 31 100 Pound Capacity Models Voltage Designation Code Voltage Specifications Cycle Phase Full Load Amps Wire Circuit Breaker AWG mm2 F-Speed Models X Q Standard 220–240 50/60 1/3 2/3 16/9 20/15 12/14 4/2.5 220–240 50/60 3 3 9 15 14 2.
Installation 100 Pound Capacity Models Voltage Designation Code Q Voltage Standard 220–240 Specifications Cycle 50/60 Phase 3 Wire 3 Electric Heat N Standard 440-480 50/60 3 3 Electric Heat P Standard 380-415 50/60 3 Full Load Amps 3 Electric Heat Circuit Breaker AWG mm2 10 15 14 2.5 74 80 4 25.0 7 15 14 2.5 37 40 8 10.0 7 15 14 2.5 34 40 8 10.0 NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Installation 20 Pound Capacity Models Voltage Designation Code Voltage Specifications Cycle Phase Wire Full Load Amps Circuit Breaker mm2 F and V-Speed Models N 440-480 50/60 3 3 2 6 2.5 X 220–240 50/60 1/3 2/3 4/3 6 2.5 220–240 50/60 3 3 3 6 2.5 21 25 2.5 2 6 2.5 13 16 2.5 Q Standard Electric Heat P Standard 380–415 50/60 3 3 Electric Heat NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Installation 30 Pound Capacity Models Voltage Designation Code P Voltage Standard 380–415 Specifications Cycle 50/60 Phase 3 Wire 3 Electric Heat Full Load Amps Circuit Breaker 3 6 2.5 13 16 2.5 mm2 NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310. Table 35 40 Pound Capacity Models Voltage Designation Code Voltage Specifications Cycle Phase Wire Full Load Amps Circuit Breaker 3 6 2.5 22 25 2.
Installation 40 Pound Capacity Models Voltage Designation Code Voltage Specifications Cycle Phase Wire Full Load Amps Circuit Breaker mm2 NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310. Table 36 60 Pound Capacity Models Voltage Designation Code Voltage Specifications Cycle Phase Wire Full Load Amps Circuit Breaker 4 6 4.0 22 25 2.
Installation 80 Pound Capacity Models Voltage Designation Code Voltage Specifications Cycle Phase Wire Full Load Amps Circuit Breaker 7 10 2.5 37 40 6.0 mm2 F-Speed Models N Standard 440-480 50/60 3 3 Electric Heat X Q Standard 220–240 50/60 1/3 2/3 12/8 16/10 2.5 220–240 50/60 3 3 8 10 2.5 72 80 16.0 7 10 2.5 33 40 4.0 7 10 2.5 37 40 6.
Installation 80 Pound Capacity Models Voltage Designation Code Voltage Specifications Cycle Phase Wire Full Load Amps Circuit Breaker mm2 NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310. Table 38 100 Pound Capacity Models Voltage Designation Code Voltage Specifications Cycle Phase Wire Full Load Amps Circuit Breaker 7 10 2.5 38 40 10.
Installation 125 Pound Capacity Models Voltage Designation Code Voltage Specifications Cycle Phase Wire Full Load Amps Circuit Breaker mm2 N 440–480 50/60 3 3 10 15 2.5 P 380–415 50/60 3 3 10 15 2.5 Q 200–240 50/60 3 3 11 15 2.5 NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Installation Chemical Injection Using Internal 24VAC Control Transformer Supply Dispensing Capacities 20–100 125 Number of liquid chemical supply signals [OPL only] 4 4 Number of supply compartments 4 0 or 5 [optional] Number of external liquid supply connections 5 5 Liquid supply connection size 3/8 in. [8 mm] NOTE: Using the Internal 24VAC 300 Milliamp Control Transformer is recommended by Alliance Laundry Systems.
Installation 3 2 4 1 5 6 7 = Neutral = Power PHM821N_SVG 1. 2. 3. 4. 5. 6. 7. External Supply Power Output Internal Control Transformer RELAY COM Terminal External Dispenser Input Signal Common Red Jumper Wire 24VAC Terminal 24VAC COM Terminal Figure 33 Chemical Injection Using External AC Power Source NOTE: An External AC Power Source is NOT provided by Alliance Laundry Systems. NOTE: Power for external supplies must not be derived from the high-voltage main power connection point. 1.
Installation 3 1 4 2 = Neutral = Power 5 PHM823N_SVG 1. 2. 3. 4. 5. External Supply Power Output Red Jumper Wire External Supply Input Signal Common VAC Power Terminal VAC RETURN Terminal Figure 34 External Supply Signals CAUTION Do not attempt to increase fuse rating or alter wiring of external chemical supply terminal strip in such as way that may conflict with the suggested methods provided on the Optional External Supply Wiring Diagram.
Installation 3 = Neutral = Power 1 2 PHM822N_SVG 1. ES1 Power supply 2. K1 Contact 3. Supply 1 Signal Figure 35 3 = Neutral = Power 1 2 PHM824N_SVG 1. ES1 Power supply 2. K1 Contact 3. Supply 1 Signal Figure 36 Connection of External Liquid Supplies 20–100 Pound OPL Models 1. Facing the rear of the machine, locate the five 3/8 inch supply hose connections found on the right-hand side of the valve panel. Refer to Figure 37 . 1 CHM2388N_SVG Valve Panel-Rear View 1.
Installation 3. Remove plastic debris. 4. Attach the external supply hoses to the ports at each of the drilled holes. 5. Secure with proper clamps. NOTE: Do not attempt to make chemical injection supply pump electrical connections to points other than those provided specifically for that purpose by the factory. 125 Pound OPL Models [With Optional Dispenser] Refer to Figure 38 . 1. Remove plugs from base. Plugs are assembled inside tubing ring. 2. Install strain reliefs with the seal nuts. 3.
Start Up Start Up Pallet Jack cover Plate Installation [80 and 100 Pound Models Only] After machine is fully installed, the optional pallet jack cover plate can be installed. 1. Locate the two holes on the front of the machine base frame. Refer to Figure 39 . 4 1 3 2 1 CHM2392N_SVG 1. 2. 3. 4. Nut Cover Plate Stud Machine Base Frame Figure 39 2. Using the hardware from removing plate from back panel, install the cover plate to the machine base frame.
Operation Operation Operating Instructions WARNING 1. Turn on main power source [circuit breaker]. 2. Turn handle clockwise to open. Refer to Figure 40 . To prevent personal injury, avoid contact with inlet water temperatures higher than 125° Fahrenheit [51° Celsius] and hot surfaces. W748 6. Select the desired soil setting [select models only], cycle setting [select models only] and cycle/temperature. The LED indicator(s) for that cycle will light. CHM2243N_SVG Figure 40 3.
Operation a. DETERGENT 1 2 CHM2227N_SVG CHM2228N_SVG 1. Liquid Detergent 2. Powder Detergent b. BLEACH 3 4 CHM2229N_SVG 3. Liquid Bleach CHM2230N_SVG 4. Powder Bleach c. SOFTENER 5 CHM2231N_SVG 5. Liquid Softener Table 43 Part No.
Maintenance Maintenance Maintenance 4. Inspect all chemical inlets, lines and connections for leaks. WARNING WARNING Sharp edges can cause personal injury. Wear safety glasses and gloves, use proper tools and provide lighting when handling sheet metal parts. W366R1 IMPORTANT: Replace all panels that are removed to perform service and maintenance procedures. Do not operate the machine with missing guards or with broken or missing parts. Do not bypass any safety devices.
Maintenance 3. On machines equipped with an automatic chemical supply system, check chemical connections by inspecting all connections and chemical hoses for leaks or cracks. Flat-Pulley Alignment IMPORTANT: Chemical leaks can quickly cause permanent damage to the machine components and structure. Model Monthly NOTE: Disconnect power to the machine at its source before performing the monthly maintenance procedures. 1. Check belt(s) require replacement or adjustment.
Maintenance c. Clean with soapy water and reinstall. Replace if worn or damaged. Torque Quarterly NOTE: Disconnect power to the machine at its source before performing the quarterly maintenance procedures. 1. Tighten door hinges and fasteners, if necessary. 2. Tighten anchor bolts, if necessary. 3. Tighten anchor bolts as specified in the Machine Mounting and Grouting section, if necessary. 4. Verify that the drain motor shield is in place and secure, if so equipped. 5.
Disposal of Unit Disposal of Unit This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Refer to Figure 45 . Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.