Specifications

30 Pound Capacity Models
Voltage Designation Specifications
Code Voltage Cycle Phase Wire
Full
Load
Amps
Circuit
Breaker AWG mm2
P Standard 380–415 50/60 3 3 3 15 14 2.5
Electric
Heat
13 15 14 2.5
NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Table 28
40 Pound Capacity Models
Voltage Designation Specifications
Code Voltage Cycle Phase Wire
Full
Load
Amps
Circuit
Breaker AWG mm2
F and V-Speed Models [unless otherwise noted]
X [F-speed] 220–240 50/60 1/3 2/3 6/4 15 14 2.5
X [V-speed] 220–240 50/60 1/3 2/3 7/4 15 14 2.5
Q Standard 220–240 50/60 3 3 4 15 14 2.5
Electric
Heat
42 50 8 10.0
N Standard 440-480 50/60 3 3 3 15 14 2.5
Electric
Heat
22 30 10 6.0
P Standard 380–415 50/60 3 3 3 15 14 2.5
Electric
Heat
25 30 10 6.0
Installation
Part No. F8429301ENR13
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 55