Network Hardware User Manual

16 505942
Troubleshooting
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
:30 - Timeout waiting for Biberon
insertion
- Bad firmware in reader
:31 - Hotlisted card inserted into the
reader
- Card hotlisted After control destroys card, the
error is cleared
:50 - Loyalty purse read error - Bad card
:56 - Loyalty purse write error - Bad card
Right-
most
dp lit
All
- Network communication error - Communication problem Error ends at good
communication
Err
All
- Coin error - Invalid coin pulse(s) Error ends after several
seconds
Alrm
All
- Breakin alarm error - Service door or coin vault
switches
Error ends after several
seconds
OFF
All
- Breakin alarm shutdown error - Service door or coin vault
switches
Cycle power to clear error
E:FL
Topload
Frontload
WX
- Fill error - Maximum fill time exceeded Cycle power to clear error
E:dr
Topload
WX
- Drain error - Maximum drain time
exceeded or water sensed at
end of a spin step
Cycle power to clear error
E:SP
Frontload
WX
- SPI communications error - Internal communication
problem
Cycle power to clear error
E:OP
Dryer
WX
- Open temperature sensor error - Bad sensor or wiring Cycle power to clear error
E:SH
Dryer
WX
- Shorted temperature sensor error - Bad sensor or wiring Cycle power to clear error
E:dL
Frontload
WX
- Door lock error - Unable to lock or unlock the
loading door
Error cleared when door lock
condition is corrected
E:dO
Frontload
WX
- Door open error - Door opened during a
running cycle
Cycle power to clear error
E:Ub
Frontload
WX
- Unbalance error - Unable to balance a load Error cleared after EOC (FL)
Error cleared after 1 min.
(WX)
E:dF
WX
- Motor failure error - Motor failure Cycle power to clear error
E:HT
WX
- Heater error - Maximum heat time
exceeded
Cycle power to clear error
E:Pr
WX
- Pressure switch sequence error - Pressure switches out of
sequence
Cycle power to clear error
Error Codes (continued)
Display Machine Error Description Error Cause Error Condition Exit