Service Stacked Dryers Metered and Nonmetered See Page 6 for Model Numbers PERM PRESS DELICATE FLUFF (NO HEAT) NORMAL IN USE FABRIC SELECTOR PUSH TO START PUSH TO START PERM PRESS NORMAL DELICATE IN USE FLUFF (NO HEAT) FABRIC SELECTOR Commercial Dryer D330P Part No.
Table of Contents Section 1 – Safety Information .........................3 Section 5 – Service Procedures .......................23 Locating an Authorized Servicer: ............................4 19. Access Panel ....................................................23 20. Control Panel and Controls (Electromechanical Metered and Nonmetered) ...............................24 21. Control Cabinet Front ......................................30 22. Control Panel Overlay .....................................
Section 7 – Test Procedures ............................75 57. Drive Motor .....................................................75 58. Burner System Operation – Silicon Carbide Ignition...................................78 59. Electrical Circuit To Ignition System – Silicon Carbide Ignition...................................79 60. Gas Valve Coils Check – Silicon Carbide Ignition...................................80 61. Sensor Check – Silicon Carbide Ignition.........81 62.
Section 1 Safety Information Throughout this manual and on machine decals, you will find precautionary statements (“CAUTION,” “WARNING,” and “DANGER”) followed by specific instructions. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine. a DANGER Danger indicates the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the danger is ignored.
Section 1 Safety Information WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.
Section 2 Introduction Customer Service If literature or replacement parts are required, contact the source from whom the machine was purchased or contact Alliance Laundry Systems at (920) 748-3950 for the name and address of the nearest authorized parts distributor. For technical assistance, call (920) 748-3121. Nameplate Location When calling or writing about your dryer, be sure to mention model and serial numbers. Model and serial numbers are located on nameplate.
Section 2 Introduction Model Identification Information in this manual is applicable to these dryers.
Section 2 Introduction How Your Dryer Works CYLINDER LINT FILTER HEATER DUCT EXHAUST FAN DELICATE AIR DUCT PERM PRESS FLUFF (NO HEAT) NORMAL TOR FABRIC SELEC START PUSH TO IN USE START PUSH TO IN USE DELICATE PERM PRESS NORMAL GAS VALVE FLUFF (NO HEAT) TOR FABRIC SELEC Commercial Dryer CYLINDER LINT FILTER HEATER DUCT EXHAUST FAN AIR DUCT D289SE3A GAS VALVE The dryer uses heated air to dry loads of laundry.
Section 3 Troubleshooting WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.
Section 3 Troubleshooting WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 2.
Section 3 Troubleshooting WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 3.
Section 3 Troubleshooting WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 5.
Section 3 Troubleshooting WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 6.
Section 3 Troubleshooting WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 9.
Section 3 Troubleshooting WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 11.
Section 3 Troubleshooting WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 13.
Section 3 Troubleshooting WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 14.
Section 4 Grounding WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 15.
Section 4 Grounding WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 16.
Section 4 Grounding WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 17.
Section 4 Grounding WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 18.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.
Section 5 Service Procedures CONTROL CABINET STRAIN RELIEF GROUND WIRE (Green) TIMER SCREW SCREW TIMER KNOB ASSEMBLY GROUND CLIP CAM OVERLAY LOCK ASSEMBLY SETSCREW TEMPERATURE SELECTOR SWITCH LOCKWASHER PUSH-TO-START SWITCH ASSEMBLY SETSCREW NUT INDICATOR LIGHT CONTROL KNOB ASSEMBLY KNURLED NUT NUT CONTROL PANEL OVERLAY CONTROL PANEL FRAME LOCKWASHER D140PE3A Figure 10 CONTROL PANEL AND CONTROLS (Nonmetered) (Model SSE007*A3000) 505039 25
Section 5 Service Procedures SCREW TIMER BRACKET COUNTER KIT SCREW TIMER CONTROL CABINET WRAPPER SCREW SLIDE EXTENSION COIN SLIDE GUIDE SCREW CAM STRAIN RELIEF LOCK ASSEMBLY SCREW GROUND CLIP CONTROL CABINET FRONT FABRIC SELECTOR SWITCH CONTROL PANEL OVERLAY LOCKWASHER PUSH-TO-START SWITCH ASSEMBLY NUT LOCKWASHER CONTROL PANEL SETSCREW CONTROL KNOB ASSEMBLY KNURLED NUT INDICATOR LIGHT NUT D361PE3A Figure 11 CONTROL PANEL AND CONTROLS (Coin Slide Ready) (Models HSE117*C2802, HSE117*C2902, HS
Section 5 Service Procedures LOCKNUT DUAL COIN DROP STRAIN RELIEF MULTIPLIER CONTROL CABINET FRONT CAM LOCK ASSEMBLY ELECTRONIC CONTROL CONTROL CABINET WRAPPER SCREW CONTROL PANEL GRAPHIC OVERLAY D374PE3A Figure 12 CONTROL PANEL AND CONTROLS (Coin Drop) (Models HSE517*C2802, HSE517*C2902, HSG519*C0902, SSE417*A3000, SSE417*A4350 and SSG419*A3000) 505039 27
Section 5 Service Procedures STRAIN RELIEF CONTROL CABINET FRONT SCREW CONTROL CABINET WRAPPER CAM LOCK ASSEMBLY ELECTRONIC CONTROL SCREW CONTROL PANEL GRAPHIC OVERLAY D352PE3A Figure 13 CONTROL PANEL AND CONTROLS (Card Reader Ready) (Models HSE617*C2802, HSE617*C2902 and HSG619*C0902) 28 505039
Section 5 Service Procedures STRAIN RELIEF CONTROL CABINET FRONT SCREW CONTROL CABINET WRAPPER CAM LOCK ASSEMBLY ELECTRONIC CONTROL SCREW CONTROL PANEL GRAPHIC OVERLAY D353PE3A Figure 14 CONTROL PANEL AND CONTROLS (Card Reader Installed) (Models HSE717*C2802, HSE717*C2902 and HSG719*C0902) 505039 29
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 21. CONTROL CABINET FRONT a. Unlock control panel.
Section 5 Service Procedures SCREW COIN FUNNEL KIT BOLT SCREW NUT WASHER CONTROL CABINET WRAPPER BASE (Upper Dryer) CAGED NUT CONTROL FRONT CABINET SCREW SCREW SCREW SCREW SCREW LOCATOR SCREW LOCATOR CABINET (Lower Dryer) CAGED NUT FRONT PANEL (Lower Dryer) D333PE3A Figure 16 CONTROL CABINET (Coin Slide Ready) (Models HSE117*C2802, HSE117*C2902, HSG119*C0902, SSE117*A3000, SSE117*A4350, SSE117*A5412, SSG119*A3000, SSG119*A3058, SSG119*A5412 and SSG119*A5480) 505039 31
Section 5 Service Procedures SCREW WASHER SCREW CONTROL CABINET WRAPPER CAGED NUT SCREW BRACKET SWITCH CONTROL FRONT CABINET SCREW SCREW SCREW SCREW SCREW LOCATOR SCREW LOCATOR CAGED NUT CABINET (Lower Dryer) D354PE3A FRONT PANEL (Lower Dryer) Figure 17 CONTROL CABINET (Coin Drop) (Models HSE517*C2802, HSE517*C2902, HSG519*C0902, SSE417*A3000, SSE417*A4350 and SSG419*A3000) 32 505039
Section 5 Service Procedures SCREW WASHER SCREW CONTROL CABINET WRAPPER CONTROL FRONT CABINET SCREW SCREW SCREW SCREW SCREW LOCATOR SCREW LOCATOR CAGED NUT CABINET (Lower Dryer) FRONT PANEL (Lower Dryer) D355PE3A Figure 18 CONTROL CABINET (Card Reader Ready) (Models HSE617*C2802, HSE617*C2902 and HSG619*C0902) 505039 33
Section 5 Service Procedures SCREW WASHER SCREW CONTROL CABINET WRAPPER CARD READER SCREW CONTROL FRONT CABINET INSTRUCTIONS CardM a Systetem IN SE RT RD SCREW SCREW CA HER E SCREW SCREW SCREW LOCATOR SCREW LOCATOR CAGED NUT CABINET (Lower Dryer) D356PE3A FRONT PANEL (Lower Dryer) Figure 19 CONTROL CABINET (Card Reader Installed) (Models HSE717*C2802, HSE717*C2902 and HSG719*C0902) 34 505039
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 22. CONTROL PANEL OVERLAY (Electromechanical Models) a.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 24. ACCUMULATOR (Electromechanical Metered Models) a.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 25.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 26. COIN DROP a. Removal (1.) Unlock control panel.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 (8.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 (3.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 28. CABINET TOP (Upper Dryer) a.
Section 5 Service Procedures Reversing Door Procedure The door on this dryer is completely reversible. To reverse door proceed as follows: 1 2 3 B A D312S D377S D311S Pull bottom of door liner out, then pull down, removing door liner from door panel. Remove all nine screws. Remove four hinge attaching screws. 4 5 6 B A D314S D315S D313S Rotate door panel 180 degrees as shown. 7 Remove door strike from door liner and reinstall on opposite side.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 29. INNER AND OUTER DOOR PANELS AND DOOR PULL a.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 31. DOOR SEAL (Figure 33) a.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 32. FRONT PANEL AND PANEL SEAL (Figure 35) a.
Section 5 Service Procedures SCREW HOLD-DOWN CLIP DOOR SWITCH FRONT PANEL SEAL LOCATOR LABEL DOOR CATCH NAMEPLATE HINGE HOLE PLUGS DOOR CATCH FRONT PANEL SCREW SCREW LOCATOR LABEL ACCESS PANEL SCREW D288PE3D Figure 35 46 505039
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 35. LINT FILTER (Figure 36) a.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 37. DOOR HINGE (Figure 36) a.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 IMPORTANT: The igniter is very fragile.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 41. LIMIT THERMOSTAT a.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 44. AIR DUCT a. Lower Air Duct (1.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 45. MOTOR AND EXHAUST ASSEMBLY a.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 m. Motor (1.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 46. FRONT BULKHEAD ASSEMBLY a.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 d. Disconnect wires from door switch. See Figure 34.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 48. CYLINDER ASSEMBLY a.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 49. REAR SEAL a.
Section 5 Service Procedures REAR SEAL OUTLET COVER REAR BULKHEAD ATTACHING SCREWS REAR BULKHEAD ATTACHING SCREWS CYLINDER ROLLER HEATER BOX CYLINDER ROLLER EXHAUST DUCT SCREW D298SE3B Figure 53 505039 63
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 50. CYLINDER ROLLERS a.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 52. REAR BULKHEAD AND HEATER DUCT a.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 j. Electric Models: (1.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 53. TERMINAL BLOCK OR POWER CORD a. Terminal Block: (1.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 b. Power Cord: (1.) Remove access plate on rear of cabinet. (2.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 54. CABINET AND BASE a. Unlock control panel. See Figure 8A. b.
Section 5 Service Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.
Section 6 Adjustments WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 55.
Section 6 Adjustments WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 56. BURNER FLAME (Gas Models) a.
Section 6 Adjustments SHUT-OFF VALVE HANDLE (Shown in Open Position) AIR SHUTTER LOCKSCREW AIR SHUTTER D265SE3B 1/8" PIPE PLUG (For checking manifold pressure) Figure 59 SILICON CARBIDE IGNITION SYSTEM AIR SHUTTER LOCKSCREW SHUT-OFF VALVE HANDLE (Shown in Open Position) WR AIR SHUTTER 1/8" PIPE PLUG (For checking manifold pressure) D363SE3A Figure 60 SILICON NITRATE IGNITION SYSTEM 505039 73
Section 7 Test Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.
Section 7 Test Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 c.
Section 7 Test Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 d.
Section 7 Test Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.
Section 7 Test Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 59.
Section 7 Test Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.
Section 7 Test Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 61. SENSOR CHECK – SILICON CARBIDE IGNITION a.
Section 7 Test Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.
Section 7 Test Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 64.
Section 7 Test Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.
Section 7 Test Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 67. IGNITER CHECK – SILICON NITRATE IGNITION a.
Section 7 Test Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 69. THERMAL FUSE (Electric Models) a.
Section 7 Test Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 72. FABRIC SELECTOR SWITCH a. Unlock control panel. See Figure 8A.
Section 7 Test Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 74. ACCUMULATOR (Metered Models) a. Unlock control panel.
Section 7 Test Procedures WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded. W001R1 75. DOOR SWITCH a.
Section 8 Internal Wiring of Dryer Motor Switch WARNING To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the dryer(s) before servicing. • Close gas shut-off valve to gas dryer(s) before servicing. • Never start the dryer(s) with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the dryer is properly grounded.