2. Connect the conduit-encased leads to the disconnect switch,
or circuit breaker. Connect the wire leads to the appropriate
labeled terminal on the terminal block. The ground wire must
be connected to the ground connection as shown in Figure
17 , Figure 18 or Figure 19 .
3. Check the electrical service phase sequence (three phase on-
ly). If one of the power leads is a “high leg,” connect it to lead
L3 in the tumble dryer. The cylinder must rotate clockwise
and the fan must rotate counterclockwise (as viewed from the
front of the tumble dryer – with selector switch in non-reverse
position). If not, interchange leads L1 and L2 in the tumble
dryer connection box.
Jumper Configuration Instructions
Changing the transformer configuration jumper is required, PRI-
OR TO SUPPLYING POWER TO THE MACHINE, if any of
the following apply:
IMPORTANT: Failure to install the proper configuration
jumper may result in damage to sensitive electronic
controls and may void warranty.
You have 400 – 415 Volt service and are connecting a model
rated for 380 Volt operation.
Ferrite Ring Installation
Gas and Steam Models with RM Control Suffix Only (Models Through 7/31/11)
The ferrite ring provided in the literature packet must be installed over the power leads during connection of electrical service. The
ferrite protects the sensitive electronic controls from destructive electrical disturbances which may be present on power lines to the
machine. Failure to properly install the ferrite ring may result in damage to the electronic controls and will void control warranty.
To install:
1. Immediately after connection of power leads and before ap-
plying power to machine, locate each of the incoming service
leads including ground.
2. Snap the ferrite ring closed over all the service leads inside of
the contactor box as shown. It is important that the ferrite ring
be installed inside the contactor box. Refer to Figure 20 . Do
not install the ferrite outside of the box or other area. Make
sure that service leads are in the center of the ferrite before
closing the ring so as not to pinch or damage leads.
Electrical Requirements
48
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458101ENR9