Installation/Operation Supplement Automatic Washers NOTE: This manual is only a supplement. Refer to installation/operation manual for full instructions. W001C W001C Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) www.comlaundry.com Part No.
Installation/Operation Supplement WARNING For your safety and to reduce the risk of fire or an explosion, do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. W022E IMPORTANT: Read the complete INSTALLATION/OPERATION INSTRUCTIONS before using the washer.
Installation/Operation Supplement Notes 2 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 201071
Installation/Operation Supplement Table of Contents Important Safety Instructions ........................................................... 5 Installation........................................................................................... Dimensions and Specifications............................................................. Installing the Washer ............................................................................ Step 1: Remove the Shipping Brace and Shipping Plug..................
Installation/Operation Supplement Notes 4 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 201071
Installation/Operation Supplement Important Safety Instructions (Save These Instructions) 10. Do not tamper with the controls. WARNING To reduce the risk of fire, electric shock, serious injury or death to persons when using your washer, follow these basic precautions: W023 1. Read all instructions before using the washer. 2. Refer to the EARTHING INSTRUCTIONS in the INSTALLATION manual for the proper earthing of the washer. 3.
Installation/Operation Supplement 21. Loading door MUST BE CLOSED any time the washer is to agitate or spin. DO NOT bypass the loading door switch by permitting the washer to agitate or spin with the loading door open. A brake will stop the washtub within seconds if the loading door is opened during spinning. If the washtub does not stop when the loading door is opened, remove the washer from use and call the service person. 22.
Installation/Operation Supplement Installation Dimensions and Specifications 650 mm (25.6 in.) *925 mm (36.5 in.) *1092 mm (43 in.) *737 mm (29 in.) *1346 mm (53 in.) 711 mm (28 in.) 10.2 mm (0.4 in.) 660 mm (26 in.) TLW1030N TLW1030N *With leveling legs turned into base.
Installation/Operation Supplement Installing the Washer Step 3: Connect Water Inlet Hoses NOTE: This manual is only a supplement. Refer to installation/operation manual for full instructions. Hoses Without Metric Coupling Step 1: Remove the Shipping Brace and Shipping Plug IMPORTANT: The shipping brace and plug should be saved and must be reinstalled whenever washer is moved or transported to a new location. Insert rubber washers in water inlet hose couplings.
Installation/Operation Supplement Step 4: Connect Drain Hose to Drain Receptacle High Standpipe Installation 2 1 3 2 1 4 TLW875N TLW875N 1 2 3 4 TLW873N 1 2 Retainer Clamp Standpipe Adapter Standpipe Adapter Drain Hose Tie-Down Strap Standpipe (Standpipes higher than 122 cm [4 ft.] are not recommended) Figure 5 Figure 7 IMPORTANT: Drain receptacle must be capable of handling a minimum of 3.2 cm (1-1/4 inch) outside diameter drain hose.
Installation/Operation Supplement Sink Installation Laundry Tub Installation 3 2 1 1 TLW878N TLW878N 1 Tie-Down Strap (Tape if necessary) Figure 11 TLW877N 1 2 3 Drain Hose Tie-Down Strap or Wire Tie Cabinet Top Hinge Figure 9 In-the-Wall Installation 1 2 W514I W514I 1 2 Tie-Down Strap (Tape if necessary) Standpipe Adapter Figure 10 10 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 201071
Installation/Operation Supplement Step 5: Position and Level the Washer Step 7: Add Water to the Washer 3 2 1 W391I 4 W391I Figure 14 5 W179I W179I 1 2 3 4 5 Step 8: Check Lid Switch Rubber Foot Washer Base Level Locknut Leveling Leg Figure 12 Step 6: Plug In the Washer W376IE0C Figure 15 Step 9: Check Installation W422I W422I Figure 13 201071 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 11
Installation/Operation Supplement Electrical Requirements Earthing Instructions 230 Volt/50 Hertz The washer must be earthed. In the event of malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. The washer is equipped with a cord having an equipment-earthing conductor and a threeprong earthing plug.
Installation/Operation Supplement Water Supply Requirements 1 NOTE: This manual is only a supplement. Refer to installation/operation manual for full instructions. 2 WATER MIXING VALVE WARNING Under certain conditions, hydrogen gas may be produced in a hot water system that has not been used for two weeks or more. HYDROGEN GAS IS EXPLOSIVE.
Installation/Operation Supplement Notes 14 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 201071
Installation/Operation Supplement Operation Operation Instructions Step 3: Close Lid NOTE: This manual is only a supplement. Refer to installation/operation manual for full instructions. Step 1: Add Detergent W318IE0C Figure 19 Step 4: Set Water Level Selector CPW70 CPW69 LOWEST WATER FILL HIGHEST WATER FILL W395I Figure 17 Step 2: Load Laundry CPW189 CPW189 Load dry clothes loosely into washtub – DO NOT overload! (7 kg maximum dry clothes load.
Installation/Operation Supplement Step 6: Set Timer to Proper Setting Step 7: Start Washer Pull the timer knob to start water fill. Agitation will begin when the water level reaches the level selected.
Installation/Operation Supplement Maintenance NOTE: This manual is only a supplement. Refer to installation/operation manual for full instructions. Reinstallation of Shipping Materials Shipping Brace Open the washer lid and place the brace over the washer agitator, placing the back of the brace into the lid opening first. 1 Shipping Plug The plug fits into two openings: the base opening and the shipping plug opening on the bottom of the movable pivot dome.