Installation Instructions for Stacked Dryers Inside ...................................... Dimensions ........................................................................ Before You Start ................................................................ Installing the Dryer ............................................................ Installer Checklist ..............................................................
WARNING FOR YOUR SAFETY, the information in this manual must be followed to minimize fire or explosion or to prevent property damage, personal injury or death. the risk of W033 ° Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. ° WHAT TO DO IF YOU SMELL GAS: - Do not try to light any appliance. - Do not touch any electrical switch; do not use any phone in your building. - Clear the room, building or area of all occupants.
Dimensions 23.5 in. (59.7 cm) i i J 15.4 in. -(39.1 cm) 8.0 in. (20.3 cm) g 5.25 in. (13.3 cm) j ! ...... lifT', I;%_.j I ° °i..... i° ° g_ O4 O4 c; L l'l t O3 l 15.44 in. *4.5 in. (39.2 cm) (68.3 cm) (11.4 cm) 0.4 in. (1.1 cm) ELECTRIC DRYERS DRY2212N * With leveling legs turned into base. I_ 23.5 cm) in. -(59.7 i i' 15.4 in. 8.0 in. (20.3 cm) (39.1 cm) 5.25 in. (13.3 cm) I 1 1 \ ¢: e-_,_ _ 28 in. S" (71.1 cm) \\ 2.3 in. -- 0.4 in. (1.1 cm) "15.44 in. (39.
Before You Start Parts Supplies An accessories It includes: For most installations, are: the basic supplies you will need 2 4 /. Included bag has been shipped inside your dryer. • Installation Instructions • User's Guide • Product • Warranty • Three screws (electric dryers only). Refer to Connecting Power Cord sections in Step 4 of Installation.
Installing the Dryer No other fuel burning appliance the same closet with the dryer. Step 1" Position and Level the Dryer should be installed in The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. Install dryer before washer. This allows room for attaching exhaust duct. Select a location with a solid floor. Dryers installed in residential garages must be elevated 18 inches (46 cm) above the floor.
Place the dryer in position, and adjust the legs until the dryer is level from side to side and front to back. The dryer must not rock. WARNING This gas appliance contains or produces chemical or chemicals which can cause death or serious illness and which are known to the State of California to cause 2 1 a cancer, birth defects, or other reproductive harm.
• In mobile home installations, dryer exhaust duct must be secured to mobile home structure. • Dryer exhaust mobile home. Dryer exhausts dryer). duct MUST NOT terminate 220 cfm (measured Exhaust Direction The dryer can be exhausted to the outdoors through the back, left, right or bottom of the dryer. EXCEPTION: Gas dryers cannot be vented out the left side because of the burner housing. under at back of Dryer is shipped from factory ready for rear exhaust.
Step 3: (Gas Dryer Only) Connect Supply Pipe Gas Natural Gas Altitude Adjustments Altitude WARNING To reduce the risk of gas leaks, fire or explosion: • The dryer must be connected to the type of gas as shown on nameplate located in the door recess. • Use a new flexible stainless steel connector. • Use pipe joint compound insoluble in L.P. (Liquified Petroleum) Gas, or Teflon tape, on all pipe threads. • Purge air and sediment from gas supply line before connecting it to the dryer.
. Tighten all connections securely. Turn on gas and check all pipe connections (internal & external) for gas leaks with a non-corrosive leak detection fluid. NOTE: The dryer and its appliance must be disconnected from the gas system during any pressure testing at test pressures in excess of 1/2 psi Refer to Step 8 (Check Heat Source). main gas valve supply piping of that system (3.45 kPa). L.P. (Liquefied Petroleum) Gas, 2500 Btu/ft 3 (93.1 MJ/m 3) service must be supplied at 10 + 1.
Connecting Power Cord with Three-Wire Plug NOTE: Four-wire cord is required for mobile homes or where codes do not permit grounding through neutral. NOTE: The power cord is NOT supplied with the electric dryer. Type of power cord and gauge of wire must conform to local codes and instructions. POWERSUPPLY POWER SUPPLY The method of wiring the dryer is optional and subject to local code requirements. NOTE: Connect the dryer to the power supply with the MAXIMUM RATED VOLTAGE listed on the nameplate.
4. Use the three screws from the accessories bag to attach the power cord wires to the terminal block. Refer to Figure 9. Connecting Power Cord with Four-Wire Plug NOTE: Four-wire cord is required for mobile homes or where codes do not permit grounding through neutral. 1 \ 1 / 4" 3 D2861 1 2 3 "L1" Terminal Neutral Terminal "L2" Terminal 0 V.A.C. Figure 9 5. Tighten all screws firmly.
3. Remove Remove ground screw and save for use in Step 5. wire and use in Step 6. 5. Attach power cord ground (green) wire to rear bulkhead using ground screw removed in Step 3. 1 D6971 Ground Screw Figure 12 DRY1920N . Use a strain relief and insert end of power cord through power supply hole. 1 2 3 4 5 6 7 White "L2" Terminal Black Green Red Neutral Terminal "LI" Terminal Figure 14 .
Step 5: Wipe Out Inside of Dryer Gas Dryer Before using dryer for the first time, use an all-purpose cleaner, or a detergent and water solution, and a damp cloth to remove shipping dust from inside dryer drum. Dryer requires 120 Volt, 60 Hertz electrical supply and comes equipped with a 3-prong grounding plug. Refer to serial plate for specific electrical requirements. NOTE: The wiring diagram is located behind control panel, inside the control cabinet.
Grounding Information The dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. The dryer is equipped with a cord having an equipment-grounding conductor and a 3 prong grounding plug. The three-prong grounding plug on the power cord should be plugged directly into a polarized three-slot effectively grounded receptacle rated 110/120 Volts AC (alternating current) 15 Amps.
Gas Dryers . To view the burner flame, remove panel of the dryer. 2. the lower front Close the loading door, start the dryer in a heat setting (refer to the Operating Instructions supplied with the dryer); the dryer will start, the igniter will glow red and the main burner will ignite. IMPORTANT: If all air is not purged out of gas line, gas igniter may go off before gas is ignited. If this happens, after approximately two minutes igniter will again attempt gas ignition. . 4.
Installer Checklist Fast Track for Installing the Unit (Refer to the manual for more detailed information) O 0 • Position and ® LEVEL • Wipe Out Inside of Dryer. ® D2551 Level the Dryer. D2561 i CHECK _ D2591 O • Connect k Dryer Exhaust System. DRY2058N CHECK Plug In the Dryer. _ CHECK Ga__2541 D2751 Electric CHECK GAS ONLY • Recheck Supply Pipe i Connect Gas Hoses. Check for Gas Leaks. _ __ ___ __ __ _ D2581 CHECK ELECTRIC ONLY • Connect Electrical Cord. L CHECK Steps 1-6.