CJT 81x 02-10-2001 11:45 Pagina 1 Installation Manual CopperJet 81x ADSL Modem series CopperJet 81x = 810, 811, 812 & 813 Allied Data TECHNOLOGIES
CJT 81x 02-10-2001 11:45 Pagina 2 CopperJet 81x Contents Packaging contents.....................................................................................................................................3 Ethernet Installation Guide.........................................................................................................................4 Installing the CopperJet 81x Configurator...............................................................................................
CJT 81x 02-10-2001 11:45 Pagina 3 CopperJet 81x Packaging contents 1. 2. 3. 4. 5. 6. 7. CopperJet 81x.. Ethernet RJ45 cross cable. USB cable (Not included with the CopperJet 812 and 813). RJ11 modem cable with PTT plug (country dependent). CD with drivers and manual. Installation manual. Power adapter (country dependent). Caution! To prevent overheating, make sure enough free space is available on both sides, and above the CopperJet 81x to permit free airflow.
CJT 81x 02-10-2001 11:45 Pagina 4 CopperJet 81x Ethernet Installation Guide Note: You must have installed an Ethernet 10Base-T card in your computer first. Installation when you already have a LAN connection. 1. Connect your CopperJet 81x with the Ethernet straight cable to your Ethernet Hub. 2. Connect your RJ11 cable to your CopperJet 81x, and into the phone outlet. 3. Connect the power adapter in a power outlet and into the CopperJet 81x Installation when you don’t have a LAN connection. 1.
CJT 81x 02-10-2001 11:45 Pagina 5 CopperJet 81x Installing the CopperJet 81x Configurator. After installing the CopperJet configurator you be able to configure the CopperJet 81x. During installation you can choose the setup you prefer, Typical this will install the most common options. Compact this will install only the CopperJet configurator. Custom you may choose the options you want to install. 1. Place the provided CD-ROM in the CD-ROM drive. Browse on the CD-ROM to the following directory.
CJT 81x 02-10-2001 11:45 Pagina 6 CopperJet 81x 3. Click on Next. 4. Click on Next. 5. Click on Next.
CJT 81x 02-10-2001 11:45 Pagina 7 CopperJet 81x 6. Click on Next. 7. Click on Next. 8. Click on Next.
CJT 81x 02-10-2001 11:45 Pagina 8 CopperJet 81x 9. Click on Finish. 10. The CopperJet configurator is now installed.
CJT 81x 02-10-2001 11:45 Pagina 9 CopperJet 81x USB Installation for Windows 98 SE. During the installation you need the official Windows 98 SE CD-ROM. A: B: C: D: Place the CD-ROM provided in the CD-ROM drive. Connect your power adapter to the power outlet and into the Copperjet 81x. Connect your USB cable into your Copperjet 81x and your computer. Connect your RJ11 cable to your CopperJet 81x and into the phone outlet. 1. Click on Next. 2. Click on Next.
CJT 81x 02-10-2001 11:45 Pagina 10 CopperJet 81x 3. Specify a location, D:\CJT_810_EU\USBdrivers and click on Next. 4. Click on Next. 5. Click on Finish.
CJT 81x 02-10-2001 11:45 Pagina 11 CopperJet 81x 6. Click on Next. 7. Click on Next. 8. Click on Next.
CJT 81x 02-10-2001 11:45 Pagina 12 CopperJet 81x 9. Click on Next. 10. Click on OK. 11. Click on Finish. 12. Click on Yes.
CJT 81x 02-10-2001 11:45 Pagina 13 CopperJet 81x USB Installation for Windows ME. A: B: C: D: Place the CD-ROM provided in the CD-ROM drive. Connect your power adapter to the power outlet and into the Copperjet 81x. Connect your USB cable into your Copperjet 81x and your computer. Connect your RJ11 cable to your CopperJet 81x and into the phone outlet. 1. Specify the location of the driver, and click on Next. 2. Specify a location, D:\CJT_810_EU\USBdrivers, and click on Next.
CJT 81x 02-10-2001 11:45 Pagina 14 CopperJet 81x 3. Click on Next. 4. Click on Finish. 5. Specify the location of the driver, and click on Next.
CJT 81x 02-10-2001 11:45 Pagina 15 CopperJet 81x 6. Specify a location, D:\CJT_810_EU\USBdrivers, and click on Next. 7. Click on Next. 8. Click on Next.
CJT 81x 02-10-2001 11:45 Pagina 16 CopperJet 81x 9. Click on Finish. 10. Click on Yes.
CJT 81x 02-10-2001 11:45 Pagina 17 CopperJet 81x USB installation for Windows 2000. A: B: C: D: Place the CD-ROM provided in the CD-ROM drive. Connect your power adapter to the power outlet and into the Copperjet 81x. Connect your USB cable into your Copperjet 81x and your computer. Connect your RJ11 cable to your CopperJet 81x and into the phone outlet. 1. Click on Next. 2. Search for a suitable driver for my device, and click on Next.
CJT 81x 02-10-2001 11:45 Pagina 18 CopperJet 81x 3. Specify a location and click on Next. 4. Copy manufacturer’s files from, D:\CJT_810_EU\USBdrivers, and click on OK. 5. Click on Next.
CJT 81x 02-10-2001 11:45 Pagina 19 CopperJet 81x 6. Click on Finish. 7. Click on Next. 8. Search for a suitable driver for my device, and click on Next.
CJT 81x 02-10-2001 11:45 Pagina 20 CopperJet 81x 9. Specify a location and click on Next. 10. Copy manufacturer’s files from, D:\CJT_810_EU\USBdrivers, and click on OK. 11. Click on Next.
CJT 81x 02-10-2001 11:45 Pagina 21 CopperJet 81x 12. Click on Yes. 13. Click on Finish.
CJT 81x 02-10-2001 11:45 Pagina 22 CopperJet 81x Using the ADSL CopperJet 81x Configurator. This configuration tool is needed to create profiles for the Copperjet 81x. Profiles can be stored for later use or can be uploaded directly to the Copperjet 81x. You can also use the configurator when a profile has been provided by your Service Provider.(You can go directly to the Upload section). 1. Start the CopperJet Configurator. 2. You can create a new profile by clicking the Edit/new profile button. 3.
CJT 81x 02-10-2001 11:45 Pagina 23 CopperJet 81x Configuring RFC1483 Bridged. 1. Select RFC1483 Bridged as profile type and click on OK. 2. Set the TCP/IP parameters. Optional: an IP Address and Subnetmask is only needed for further management use. Select the Line modulation. (ADSL connection Protocol) -Multimode -T1.413 -G.Lite -G.Dmt : Modem will detect the Modulation offered by the CO (Preferred) : ANSI ADSL Standard : G.992.2 : G.992.1 Annex A Set the ATM PVC (Virtual Circuit) parameters.
CJT 81x 02-10-2001 11:45 Pagina 24 CopperJet 81x Set Filter Table age, this is the time in seconds the device needs to store the MAC-addresses. Encapsulation. -LLC -VcMux : Logical Link Control : Null Encapsulation DNS Relay. Fill in the DNS server IP-Address, in your local network the DNS IP-Address will be the CopperJet 81x IP address.(Not needed by Bridged) Click on OK when finished, the profile will be stored in My Documents.
CJT 81x 02-10-2001 11:45 Pagina 25 CopperJet 81x Configuring RFC1483 Routed. 1. Select RFC1483 Routed as profile type and click on OK. 2. Set the LAN TCP/IP parameters. (CopperJet 81x IP-Address) Set the interface type. USB when the CopperJet 81x is connected with a USB cable. Ethernet when the CopperJet 81x is connected with a Ethernet cable. Select the Line modulation. (ADSL connection Protocol) -Multimode -T1.413 -G.Lite -G.
CJT 81x 02-10-2001 11:45 Pagina 26 CopperJet 81x You must set NAT when de LAN IP-Address differs from the WAN IP-Address. Set Routing default gateway if needed.(CopperJet 81x WAN IP-Address) DNS Relay. Fill in the DNS server IP-Address, in your local network the DNS IP Address will be the CopperJet 81x IP address. Set the DHCP server when needed. The CopperJet 81x can act as a DHCP server. Go to the DHCP server section how to configure the DHCP server.
CJT 81x 02-10-2001 11:45 Pagina 27 CopperJet 81x Configuring PPPoA. 1. Select PPPoA as profile type and click on OK. 2. Set Authentication. Fill in your Username and Password. Choose the Authentication Protocol.(PAP or CHAP) Set the LAN TCP/IP parameters. (CopperJet 81x IP-Address) The Default Gateway of your local network will be the CopperJet 81x IP-Address Set the interface type. USB when the CopperJet 81x is connected with a USB cable.
CJT 81x 02-10-2001 11:45 Pagina 28 CopperJet 81x Set NAT (Network Address Translation) if needed. You must set NAT when de LAN IP-Address differs from the WAN IP-Address. DNS Relay. Fill in the DNS server IP-Address, in your local network the DNS IP-Address will be the CopperJet 81x IP address. Set the DHCP server when needed. The CopperJet 81x can act as a DHCP server. Go to the DHCP server section how to configure the DHCP server. Click on OK when finished, the profile will be stored in My Documents.
CJT 81x 02-10-2001 11:45 Pagina 29 CopperJet 81x Configuring PPPoE. 1. Select PPPoE as profile type and click on OK. 2. Set Authentication. Fill in your Username and Password. Choose the Authentication Protocol.(PAP or CHAP) Set the LAN TCP/IP parameters. (CopperJet 81x IP-Address). The Default Gateway of your local network will be the CopperJet 81x IP-Address Set the interface type. USB when the CopperJet 81x is connected with a USB cable.
CJT 81x 02-10-2001 11:45 Pagina 30 CopperJet 81x Set NAT (Network Address Translation) if needed. You must set NAT when de LAN IP-Address differs from the WAN IP-Address. DNS Relay. Fill in the DNS server IP-Address, in your local network the DNS IP-Address will be the CopperJet 81x IP address. Set the DHCP server when needed. The CopperJet 81x can act as a DHCP server. Go to the DHCP server section how to configure the DHCP server. Click on OK when finished, the profile will be stored in My Documents.
CJT 81x 02-10-2001 11:45 Pagina 31 CopperJet 81x Configuring PPTP. 1. Select PPTP as profile type and click on OK. 2. Set the LAN TCP/IP parameters. (CopperJet 81x IP-Address). The Default Gateway of your local network will be the CopperJet 81x IP-Address Set the interface type. USB when the CopperJet 81x is connected with a USB cable. Ethernet when the CopperJet 81x is connected with a Ethernet cable. Select the Line modulation.(ADSL connection Protocol) -Multimode -T1.413 -G.Lite -G.
CJT 81x 02-10-2001 11:45 Pagina 32 CopperJet 81x Click on OK when finished, the profile will be stored in My Documents. The profile can be uploaded to the Copperjet 81x as described in the upload section.
CJT 81x 02-10-2001 11:45 Pagina 33 CopperJet 81x Configuring IPoA. 1. Select IPoA as profile type and click on OK. 2. Set the LAN TCP/IP parameters. (CopperJet 81x IP-Address) Set the interface type. USB when the CopperJet 81x is connected with a USB cable. Ethernet when the CopperJet 81x is connected with a Ethernet cable. Select the Line modulation. (ADSL connection Protocol) -Multimode -T1.413 -G.Lite -G.Dmt : Modem will detect the Modulation offered by the CO (Preferred) : ANSI ADSL Standard : G.
CJT 81x 02-10-2001 11:45 Pagina 34 CopperJet 81x Set Routing default gateway if needed.(CopperJet 81x WAN IP-Address) DNS Relay. Fill in the DNS server IP-Address, in your local network the DNS IP Address will be the CopperJet 81x IP address. Set the DHCP server when needed. The CopperJet 81x can act as a DHCP server. Go to the DHCP server section how to configure the DHCP server. Click on OK when finished, the profile will be stored in My Documents.
CJT 81x 02-10-2001 11:45 Pagina 35 CopperJet 81x Configuring the DHCP Server. This is a example how to configure the DHCP Server. 1. Select DHCP Server, and click on Configuration. 2. Click on Add.
CJT 81x 02-10-2001 11:45 Pagina 36 CopperJet 81x 3. Fill in your Subnet and Netmask. The Subnet must be in the same network as your CopperJet 81x IP Address, and click on OK. 4. Fill in the range of IP Addresses you want to use, and click on Add. Note: Do not use the CopperJet 81x IP Address in your IP range. 5. Fill in the Default or Max. lease time, this is the time in seconds you have the assigned IP Address, after this time you get a another IP Address from the DHCP Server.
CJT 81x 02-10-2001 11:45 Pagina 37 CopperJet 81x 6. Fill in the Routers IP Address, this is the CopperJet 81x IP Address, and click on Add. 7. Click on OK. 8. Click on OK when finished, the profile will be stored in My Documents. The profile can be uploaded to the CopperJet 81x as described in the upload section.
CJT 81x 02-10-2001 11:45 Pagina 38 CopperJet 81x Uploading the profile into the CopperJet 81x. With the CopperJet configurator you can upload your profile into your CopperJet 81x. 1. Start the CopperJet Configurator. 2. Click on the MAC address, and click on Upload profile. 3. Select the profile you want to upload, and click on Open.
CJT 81x 02-10-2001 11:45 Pagina 39 CopperJet 81x 4. Click on Start. 5. Wait till the CopperJet 81x has rebooted, and click on Exit. Note: Additional LAN Network settings maybe needed.
CJT 81x 02-10-2001 11:45 Pagina 40 CopperJet 81x Retrieving the profile from your CopperJet 81x. With the CopperJet configurator you will be able to retrieve your profile from your CopperJet 81x. 1. Start the CopperJet Configurator. 2. Click on the MAC address, and click on Get profile. 3. Give the profile a file name e.g Save, and click on Save. 4. Click on Ok.
CJT 81x 02-10-2001 11:45 Pagina 41 CopperJet 81x 5. Your saved profile is now stored in My Documents.
CJT 81x 02-10-2001 11:45 Pagina 42 CopperJet 81x Updating the firmware in the CopperJet 81x. With the CopperJet configurator you can upload a new firmware into your CopperJet 81x. New firmware will be available on our website. Note: Don’t disconnect the power suply, USB cable or Ethernet cable during the upload. 1. Start the CopperJet Configurator. 2. Click on the MAC address, and click on Update firmware. 3. Select the binary to upload, and click on Open.
CJT 81x 02-10-2001 11:45 Pagina 43 CopperJet 81x 4. Click on Start. 5. Click on Exit. 6. Click on Refresh, the CopperJet 81x MAC address and new firware version will be shown.
CJT 81x 02-10-2001 11:45 Pagina 44 CopperJet 81x Troubleshooting guide. This section may help when you may find some problems with the product. Please check our website: www.allieddata.com for updates on manuals, drivers and firmware. General 1. Power-LED is not burning: - Check if your power adapter is connected to your ADSL modem and the power network 2. ADSL-LED is not burning: Your ADSL modem doesn’t see the Central Office Equipment.
CJT 81x 02-10-2001 11:45 Pagina 45 CopperJet 81x 6. ADSL Profile Configurator or Loader doesn’t detect an ADSL modem in your network - Check if the modem is in the same physical LAN as the configuring PC - Check if the modem’s IP address is in the same IP-subnet as the configuring PC. This IP-address can be found in the downloaded profile using the ADSL Profile Configurator.
CJT 81x 02-10-2001 11:45 Pagina 46 CopperJet 81x Glossary ADSL Strictly speaking, Asymmetric Digital Subscriber Line defines only a way of transmitting broadband data (at speeds between 64kbps and 8Mbps) between a user’s premises (home or office) and the local telephone exchange. In order to increase the number of customers that it is possible to serve, the upstream speed (from the user) is lower than the downstream speed (to the user), so the service is ‘asymmetric’.
CJT 81x 02-10-2001 11:45 Pagina 47 CopperJet 81x Authentication will normally be performed by the BAS, probably by reference to a RADIUS server. BAS The Broadband Access Server could be described as a highly flexible and configurable ATM/PPP/IP switch/router. The function of the BAS is to ‘unwrap’ any encapsulation used to carry the TCP/IP traffic over the ATM connection and pass the data into the ISPs normal network.
CJT 81x 02-10-2001 11:45 Pagina 48 CopperJet 81x Note that ‘RFC 1483’ by itself doesn’t tell you what the protocol is - you need to know if the connection is bridged or routed to know what ‘RFC 1483’ means. DSLAM The unit in the telco’s local exchange that houses the ADSL modems and consolidates all the data connections onto a single ATM fibre connection, typically at 155Mbps currently.
CJT 81x 02-10-2001 11:45 Pagina 49 CopperJet 81x So, you place each document into its own ‘internal’ envelope before placing all the ‘internal’ envelopes inside the big one. Another, more appropriate analogy: An ISP may specify that all TCP/IP messages must be placed inside a brown envelope marked ‘PPP’ with your name and encrypted password written on it before being placed inside the ‘real’ ATM envelope and sent to the ISP.
CJT 81x 02-10-2001 11:45 Pagina 50 CopperJet 81x G.dmt = G.992.1, derived from T1.413; also known as ‘Full rate’ This is the type of ADSL most commonly implemented now. IP over LLC/SNAP This is a routed connection method and is one of the options of RFC 1483. Note that ‘RFC 1483’ by itself doesn’t tell you what the protocol is - you need to know if the connection is bridged or routed to know what ‘RFC 1483’ means.
CJT 81x 02-10-2001 11:45 Pagina 51 CopperJet 81x Showtime Jargon for the ADSL state (that may be signalled by a green ‘line’ LED being permanently on rather than flashing) equivalent to the ‘CD’ LED or ‘CONNECT’ message from a modem. May mean (if you’re unlucky and the line is bad) that you have a 32kbps connection to the DSLAM in your local exchange, since this is normally the ‘minimum’ speed defined as ‘acceptable’.
CJT 81x 02-10-2001 11:45 Pagina 52 CopperJet 81x Declaration of Conformity Manufacturer’s Name: ALLIED DATA TECHNOLOGIES B.V. Manufacturer’s Address: P.O. box 788 3200 AS Spijkenisse The Netherlands declares that the product: Product Name: CopperJet 810 Conforms to the following standard(s) or other normative document(s): EMC: EN 55022 Class A (1994) Limits and methods of measurement of radio disturbance characteristics of information technology equipment.
CJT 81x 02-10-2001 11:45 Pagina 53 CopperJet 81x INFORMATION TO USER This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for Class B Digital Device, pursuant to Part 15 of the FCC Rules.
CJT 81x 02-10-2001 11:45 Pagina 54 CopperJet 81x Declaration of Conformity Manufacturer’s Name: ALLIED DATA TECHNOLOGIES B.V. Manufacturer’s Address: P.O. box 788 3200 AS Spijkenisse The Netherlands declares that the product: Product Name: CopperJet 811 Conforms to the following standard(s) or other normative document(s): Safety: EN 60950 (1992/93) Safety of information technology equipment, including electrical business equipment.
CJT 81x 02-10-2001 11:45 Pagina 55 CopperJet 81x Declaration of Conformity Manufacturer’s Name: ALLIED DATA TECHNOLOGIES B.V. Manufacturer’s Address: P.O. box 788 3200 AS Spijkenisse The Netherlands declares that the product: Product Name: CopperJet 812 Conforms to the following standard(s) or other normative document(s): EMC: EN 55022 Class A (1994) Limits and methods of measurement of radio disturbance characteristics of information technology equipment.
CJT 81x 02-10-2001 11:45 Pagina 56 CopperJet 81x INFORMATION TO USER This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for Class B Digital Device, pursuant to Part 15 of the FCC Rules.
CJT 81x 02-10-2001 11:45 Pagina 57 CopperJet 81x Declaration of Conformity Manufacturer’s Name: ALLIED DATA TECHNOLOGIES B.V. Manufacturer’s Address: P.O. box 788 3200 AS Spijkenisse The Netherlands declares that the product: Product Name: CopperJet 813 Conforms to the following standard(s) or other normative document(s): Safety: EN 60950 (1992/93) Safety of information technology equipment, including electrical business equipment.
CJT 81x 02-10-2001 11:45 Pagina 58 CopperJet 81x Warranty This ALLIED DATA TECHNOLOGIES B.V. product is warranted against defects in material and workmanship for a period of five years from date of shipment. During the warranty period, ALLIED DATA TECHNOLOGIES B.V. will, at its option, either repair or replace products that prove to be defective. For warranty service or repair, this product must be returned to a service facility designated by ALLIED DATA TECHNOLOGIES B.V.
CJT 81x 02-10-2001 11:45 Notes: Pagina 59
CJT 81x 02-10-2001 11:45 Pagina 60 Allied Data TECHNOLOGIES Headoffice Allied Data Technologies bv Netherlands E-mail: support@allieddata.com Website: www.allieddata.com Europe E-mail : support@allieddata.com Website : www.allieddata.com Asia E-mail : support@allieddata.com Website : www.allieddata.com USA E-mail : USsupport@allieddata.com Website : www.allieddata.