AT-MC101XL AT-MC102XL AT-MC103XL AT-MC103LH Fast Ethernet Media Converters Installation Guide PN 613-10771-00 Rev.
Copyright 1998, 1999 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA USA 94086 All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn International, Corp.
Safety Warnings STANDARDS: This product meets the following standards U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
AT-MC101XL, AT-MC102XL, AT-MC103XL AT-MC103LH Fast Ethernet Media Converters The AT-MC101XL and AT-MC102XL convert IEEE 802.3u 100Base-TX to 100Base-FX multimode Fast Ethernet network connections. The AT-MC103XL and AT-MC103LH convert to FX single mode. The 100Base-FX interfaces are available in ST or SC connectors for multimode fiber cabling. For single mode cabling, the 100Base-FX is available in SC connectors only. The 100Base-TX interface uses an RJ45 shielded connector.
CLASS 1 LASER LIGHT DO NOT STARE INTO BEAM TX RX 100Base-FX 100Base-TX NML REC REC PWR LNK LNK TST NML MDI MDI-X LNK MC103LH SINGLE MODE FIBER LONG HAUL FAST ETHERNET MEDIA CONVERTER Figure 4 AT-MC103LH (SC single mode connector) Key Features The media converters have the following key features: ❑ LEDs for unit and port status ❑ MDI/MDI-X Switch ❑ NML/LNK TST Switch ❑ 100Base-TX ports participate in auto-negotiation for 100 Mbps and half- or full-duplex modes ❑ MissingLink provides
Installation Guide LEDs The PWR LED in the upper right corner of the front panel lights when the media converter is receiving power. Status LEDs are located on the front panel next to each port and described in Table 1. Table 1 LEDs LED Color State Description PWR Green ON Power is applied. NML Green ON Unit is operating in normal mode. OFF Unit is in Link Test mode. REC Green ON Data is being received on the port. LNK Green ON Link established on the port.
Auto-Negotiation The 100Base-TX ports participate in IEEE 802.3u Standard auto-negotiation with its local link partner. Note End stations used with the media converter must operate in the same duplex mode (either both full-duplex or both half-duplex). Note The media converters have an additional feature, allowing the unit to operate in 100 Mbps half-duplex mode.
Installation Guide Package Contents Make sure the media converter package contains the following items: ❑ AT-MC101XL, AT-MC102XL, AT-MC103XL, or AT-MC103LH Fast Ethernet Media Converter ❑ Four Protective Feet (for standalone use only) ❑ External AC-DC Power Adapter ❑ This Installation Guide Contact your sales representative if any items are missing or damaged. Installing the Media Converter Read the warnings below before beginning any installation.
4. Verify that the PWR LED lights green. 5. Set the unit in Link Test mode 6. Remove the dust cap from the fiber optic connectors. 7. Plug the appropriate fiber cable into the connector. See Table 3 for IEEE 802.3u cabling specifications 8. Connect the other end of the fiber cable to the desired end station. Verify that the link LED is ON. 9. If you are making a direct connection to a workstation using straightthrough cable, set the MDI/MDI-X switch to the MDI-X position. (MDI-X is the default position.
Installation Guide Note The media converters have an additional feature, allowing the unit to operate in 100 Mbps half-duplex mode. Certain applications require this mode, for example, two media converters installed in a back-to-back configuration (fiber-to-fiber) which are attached to unmanaged repeaters and/or switches that auto-negotiates with the other. Forinstructions on how to set up the media converter for this application, contact Allied Telesyn Technical Support.
Configurations Figure 9 shows a typical network configuration with a workstation connected to a switch. AT-8124XL 10/100 Switch PORT ACTIVITY RS-232 TERMINAL PORT AT-MC101XL STATUS 10BASE-T / 100BASE-TX 10BASE-T / 100BASE-TX SWITCH FAST ETHERNET 100Base-TX 100Base-FX MMF Legend 10 Mbps 100 Mbps 100 Mbps (Fiber) Workstation Figure 9 Connection to Workstation and Switch Figure 10 shows two media converters in a back-to-back configuration.
Installation Guide Troubleshooting To troubleshoot your media converter, perform the following: 1. Set the unit in the Link Test mode. 2. End stations used with the media converter must operate in the same duplex mode (either both full-duplex or both half-duplex). 3. Verify that the twisted pair cable is Category 5. 4. Verify that proper fiber cable is being used: multimode for the AT-MC101XL and AT-MC102XL, and single mode for the AT-MC103XL and AT-MC103LH.
Recommended Cables and Cable Specifications Table 3 lists the IEEE 802.3u cabling specifications for the media converters. Refer to Table 3 for cabling recommendations. Table 3 IEEE 802.3u Cabling Specifications for Media Converters 100Base-FX 100Base-TX Media 1300 nm multimode fiber, 50/125 micron 1300 nm multimode fiber, 62.
Installation Guide Technical Support and Service You can contact the reseller or distributor where you purchased your product for local assistance. If local support is unable to resolve the problem, Allied Telesyn offers technical support via fax, e-mail or telephone. Refer to Appendi xD, for technical support telephone and fax numbers or www.alliedtelesyn.com for current world-wide office locations. Warranty The media converters have a lifetime warranty. The power adapter has a one year warranty.
Appendix A Electrical Safety and Installation Requirements STANDARDS: This product meets the following standards U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
OPERATING TEMPERATURE This product is designed for a maximum ambient temperature of 40 degrees C. ALL COUNTRIES: Install product in accordance with local and National Electrical Codes. NORMEN: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen !1 !2 Hochfrequenzstörung EN55022 Klasse A WARNUNG: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen.
Installation Guide ALLE LANDE: Installation af produktet skal ske i overensstemmelse med lokal og national lovgivning for elektriske installationer. EISEN: Dit product voldoet aan de volgende eisen. !1 !2 RFI Emissie EN55022 Klasse A WAARSCHUWING: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen.
STANDARDI : Tämä tuote on seuraavien standardien mukainen !1 !2 Radioaaltojen häirintä EN55022 Luokka A VAROITUS: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin. !3 !4 Kestävyys EN50082-1 1997 VAROITUS: Tämä tuote vaatii suojattuja kaapeleita toimiakseen emissio- ja häiriönsietostandardien mukaisesti.
Installation Guide SIKKERHETSNORME : Dette produktet tilfredsstiller følgende sikkerhetsnormer !1 !2 RFI stråling EN55022 Klasse A ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler. !3 !4 Immunitet EN50082-1 1997 ADVARSEL: Dette produktet må brukes med vernede kabler for å tilfredsstille emisjons- og fritakelsesstandarder.
ESTÁNDARES: Este producto cumple con los siguientes estándares !1 !2 Emisión RFI EN55022 Clase A ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto. !3 !4 Inmunidad EN50082-1 1997 ADVERTENCIA: Este producto exige cables protectores para ajustarse a las normas de emisión e inmunidad.
Appendix B AT-MC101XL, AT-MC102XL, AT-MC103XL, and AT-MC103LH Installation Guide Feedback Please tell us what additional information you would like to see discussed in this guide. If there are topics you would like information on that were not covered in this guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of this guide.
Appendix C Technical Support Fax Order Name _________________________________________________________________ Company ______________________________________________________________ Address _______________________________________________________________ City______________________ State/Province_______________________________ Zip/Postal Code ________________ Country_______________________________ Phone______________________________ Fax________________________________ Incident Summary Model number of Allied
Appendix D Where To Find Us For Technical Support or Service Location Phone Fax Americas United States, Canada, Mexico, Central America, South America 1 (800) 428-4835 1 (918) 628-3222 Asia Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India, Hong Kong (+65) 3815-612 (+65) 3833-830 Australia Australia, New Zealand 1 (800) 000-880 (+61) 2-9438-4966 France France, Belgium, Luxembourg, The Netherlands, Middle East, Africa (+33) 1-60-92-15-32 (+33) 1-69-28-37-49 Ge