AR400 Series Router Installation and Safety Guide AR415S AR440S AR441S AR442S AR450S
AR400 Series Router AR400 Series Installation and Safety Guide Document Number 613-000313 Rev C. Copyright © 2004-2006 Allied Telesis Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Allied Telesis, Inc. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice.
Installation and Safety Guide 3 Table of Contents Electrical Safety Statements ................................................................................................... 4 Models Covered By This Guide ........................................................................................... 5 Package Contents .................................................................................................................... 5 AR450S Routers .......................................................
AR400 Series Router Electrical Safety Statements Electrical Safety IMPORTANT: This equipment must be installed in accordance with safety precautions (“Safety”, page 41). Elektrische Sicherheit WICHTIG: Für die Installation dieses Gerätes ist die Einhaltung von Sicherheitsvorkehrungen erforderlich (“Sicherheit”, Seite 44). Elektrisk sikkerhed VIGTIGT: Dette udstyr skal installeres i overensstemmelse med sikkerhedsadvarslerne (“Sikkerhed”, side 45).
Installation and Safety Guide 5 Models Covered By This Guide This Installation and Safety Guide includes information on these models: ■ AR415S ■ AR440S ■ AR441S ■ AR442S ■ AR450S You can download updates to this document from www.alliedtelesis.com/support/software. Package Contents Before beginning any installation, please check the package contents. Contact your authorised Allied Telesis distributor or reseller if any items are damaged or missing.
AR400 Series Router AR440S, AR441S and AR442S Package Contents: ■ one AR400 Series router ■ one AC power cord ■ one power cord retaining clip ■ one serial null modem cable for connecting the router to a terminal or PC ■ two UTP network cables ■ one DSL cable AR440S: two in Australia and New Zealand ■ one 19 inch rack-mount kit ■ one AR400 Series Router Installation and Safety Guide ■ one AR400 Series Router Documentation and Tools CD-ROM (includes the complete AR400 Series Document Set
Installation and Safety Guide 7 AR450S Router This section describes how to install the AR450S router. ■ “Installing the AR450S” below ■ “Configuring the AR450S” on page 9 ■ “Connecting Data Cables to the AR450S” on page 13 ■ “System LEDs on the AR450S” on page 14 For corresponding information about installing an AR415S, see “AR415S Router” on page 15. For corresponding information about installing an AR440S, AR441S or AR442S, see “AR440S, AR441S, AR442S Routers” on page 25.
AR400 Series Router Installing the Router in a Rack 1. Gather additional items. You will need: • the rack-mount kit included in the router package • a Phillips #1 screwdriver • screws and cage nuts to attach the brackets to your rack 2. Check the rack. Ensure that the rack is safely secured and that it will not tip over. Devices in a rack should be installed starting at the bottom, with the heavier devices near the bottom of the rack.
Installation and Safety Guide 9 3. Connect the provided power cord to the AC power inlet and clip it in place. Switch the router’s power switch to the ON position. The Power LED lights continuously and the System LED lights briefly. The Port LEDs also light briefly. The router is supplied with an approved power cord that incorporates a moulded plug. It must only be used with the power cord supplied. If the LEDs fail to light, the most likely cause is that the router is not receiving power.
AR400 Series Router 2. Log in and set the password. The login prompt appears on the terminal or PC. If the login prompt does not appear, press [Enter] two or three times. When the router boots for the first time it automatically creates an account with manager privileges. The account has the user name “manager” and the password is “friend”. Passwords are case sensitive. At the login prompt, enter the user name and password.
Installation and Safety Guide 11 Using the GUI to configure the AR450S This section describes how to access the GUI via a switch port in VLAN1 on the AR450S router, when the PC and the router are in the same subnet, in order to configure the router. The router’s switch ports all belong to VLAN1 by default. The GUI requires a PC and web browser. Supported browsers are Internet Explorer 5.0 or later and Netscape 6.2.2 or later, with JavaScript enabled.
AR400 Series Router 3. Enable IP. In the CLI, enter the command: enable ip 4. Assign an IP address to VLAN1. Assign the VLAN1 interface an IP address in the subnet that the PC uses, using the command: add ip interface=vlan1 ip=ipaddress mask=mask 5. Browse to the GUI. If you access the Internet through a proxy server, set your browser to bypass the proxy for the IP address you assigned to the VLAN1 interface. Point your web browser at the IP address of the VLAN interface. 6.
Installation and Safety Guide 13 Connecting Data Cables to the AR450S Connecting the router to your network: 1. Connect to the LAN. If you have not already done so, use straight-through Ethernet patch cables to connect the device(s) on your private network (LAN) to the router’s switch port(s). By default, all switch ports are members of VLAN1. 2. Connect to the DMZ port. If you have a public server to connect, use an Ethernet patch cable to connect it to the AR450S router’s Ethernet DMZ (ETH1) port.
AR400 Series Router System LEDs on the AR450S The LEDs described in the following table show the operational status and port activity for AR450S routers. LED State Function Power Green The router is receiving power and the power switch is ON. System Red or Amber Lit briefly during router start up, or the router is malfunctioning. Flashing The fan has failed. Off Normal operation. Green The port is operating at full-duplex. Off The port is operating at half-duplex.
Installation and Safety Guide 15 AR415S Router This section describes how to install the AR415S router. ■ “Installing the AR415S” below ■ “Configuring the AR415S” on page 18 ■ “Connecting Data Cables to AR415S” on page 23 ■ “System LEDs on AR415S” on page 24 For corresponding information about installing an AR450S, see “AR450S Routers” on page 7. For corresponding information about installing an AR440S, AR441S or AR442S, see “AR440S, AR441S, AR442S Routers” on page 25.
AR400 Series Router Installing an Optional PIC If you purchased an optional PIC, install it now by following the Port Interface Card Quick Install Guide. The PIC Quick Install Guide can be found with the PIC, on the Documentation and Tools CD-ROM, or can be downloaded from www.alliedtelesis.com/support/software/ . Installing the Router in a Rack 1. Gather additional items.
Installation and Safety Guide 17 6. Mount the router in the rack. Use appropriate rack mounting screws (not supplied). Applying Power to the Router 1. Check the supply voltage and the router’s rated voltage. AR400 Series routers are fitted with a universal mains power supply that will function over the range 100 VAC to 240 VAC and 50 Hz to 60 Hz. For continued protection against the risk of fire and shock hazard, replace fuses only with the same type and rating.
AR400 Series Router Configuring the AR415S By default, the DHCP server on the router is enabled, and all the switch ports belong to the default VLAN (vlan1), which has an IP address of 192.168.1.1 (“Default Configuration on AR415S, AR440S, AR441S, AR442S” on page 37). We recommend starting to configure the router using the graphical user interface (GUI), with its easy wizards. If necessary, you can then use the Command line interface (CLI) to complete your configuration.
Installation and Safety Guide 19 1. Connect the PC to a router switch port. The PC can be connected directly, or through your LAN. To connect the PC directly to the router, use a straight-through Ethernet cable to connect an Ethernet card on the PC to any one of the router’s switch ports. See the following figure. straight-through cable router ON SWITCH PORTS POWER 4 2 3 1 PIC BAY OFF POWER 100-240 VAC 50/60 Hz 2.
AR400 Series Router IP), and click Properties. In the Internet Protocol Properties dialog box, select Obtain an IP address automatically and Obtain a DNS server address automatically. Close all the dialog boxes you opened. If these new IP address settings do not take effect immediately, you may need to restart the PC. If you have disabled the router’s DHCP server, assign the PC an IP address in the same subnet as the router. The router’s default IP address is 192.168.1.1. 3. Browse to the GUI.
Installation and Safety Guide 21 6. Save the configuration. The first time you start the router, it uses the default configuration in the file boot.cfg. Save your configuration to a new file, and set the router to use this file when it restarts. We strongly recommend leaving the boot.cfg file unchanged, in case you need to revert to the original default configuration. Some wizards save the configuration automatically. If your configuration is not saved yet, the Save button is red. 7.
AR400 Series Router Set the communication parameters on your terminal or terminal emulation program to: • Baud rate: 9600 • Data bits: 8 • Parity: None • Stop bits: 1 • Flow control: Hardware See the AR400 Series Router Hardware Reference for more information on configuring emulation software. 2. Log in and set the password. The login prompt appears on the terminal or PC. If the login prompt does not appear, press [Enter] two or three times.
Installation and Safety Guide 23 To display help on a specific topic, enter: help topic Alternatively, type a question mark (?) at the end of a partially completed command to see a list of valid options. 4. Save the configuration. Save your configuration to a new file, using the command: create config=filename.cfg and set the router to load this file when it restarts, using the command: set config=filename.cfg We recommend leaving the boot.
AR400 Series Router System LEDs on AR415S The LEDs described in the following table show the operational status and port activity for the AR415S router. LED State Function PWR Green The router is receiving power and the power switch is ON. SYS Amber Lit briefly during router start up, or the router is malfunctioning. Off Normal operation. Green A port interface card (PIC) is correctly installed and has been detected by the router.
Installation and Safety Guide 25 AR440S, AR441S, AR442S Routers This section describes how to install the AR440S, AR441S and AR442S routers. ■ “Installing the AR440S, AR441S, AR442S” below ■ “Configuring the AR440S, AR441S, AR442S” on page 29 ■ “Connecting Data Cables to AR440S, AR441S, AR442S” on page 35 ■ “System LEDs on AR440S, AR441S, AR442S” on page 36 For corresponding information about installing an AR415S, see “AR415S Router” on page 15.
AR400 Series Router Installing an Optional PIC If you purchased an optional PIC, install it now by following the Port Interface Card Quick Install Guide. The PIC Quick Install Guide can be found with the PIC, on the Documentation and Tools CD-ROM, or can be downloaded from www.alliedtelesis.com/support/software/. Installing the Router in a Rack 1. Gather additional items.
Installation and Safety Guide 27 6. Mount the router in the rack. Use appropriate rack mounting screws (not supplied). Installing the Router on a Wall You can install the router on a firm wall. 1. Gather additional items. You will need: • a wall mount bracket kit (ordered from your authorised Allied Telesis distributor or reseller) • a Phillips #1 screwdriver • a Phillips #2 screwdriver • If you are fixing the router to a solid masonry or hollow wall, you need equipment to drill a 6 mm hole.
AR400 Series Router Applying Power to the Router 1. Check the supply voltage and the router’s rated voltage. AR400 Series routers are fitted with a universal mains power supply that will function over the range 100 VAC to 240 VAC and 50 Hz to 60 Hz. For continued protection against the risk of fire and shock hazard, replace fuses only with the same type and rating. Warning The specific power supply requirements for a particular model are clearly displayed on the rear or underside of the router.
Installation and Safety Guide 29 Configuring the AR440S, AR441S, AR442S By default, the DHCP server on the router is enabled, and all the switch ports belong to the default VLAN (vlan1), which has an IP address of 192.168.1.1 (“Default Configuration on AR415S, AR440S, AR441S, AR442S” on page 37). We recommend starting to configure the router using the graphical user interface (GUI), with its easy wizards. If necessary, you can then use the Command line interface (CLI) to complete your configuration.
AR400 Series Router 1. Connect the PC to a router switch port. The PC can be connected directly, or through your LAN. To connect the PC directly to the router, use a straight-through Ethernet cable to connect an Ethernet card on the PC to any one of the router’s switch ports. See the following figure. PC Router 4 2 3 1 POWER ON 100-240 VAC 50/60 Hz 2.
Installation and Safety Guide 31 2. Set PC to automatic IP address. Set the PC to accept an IP address assigned to it by the router’s DHCP server. In Windows XP: From the Start menu, select Control Panel > Network and Internet Connections > Network Connections. Select the connection, right-click and select Properties. In the connection Properties dialog box General tab, select Internet Protocol (TCP/IP), and click Properties.
AR400 Series Router 5. Configure the router. You can configure the router using the GUI wizards or menu. Important To ensure configuration settings are saved correctly, use the GUI menus and buttons to navigate, not your browser’s buttons. Caution As a security precaution, change the password as soon as possible. Remember the new password, as there is no way to retrieve it if it is lost. Use the wizard and other configuration menu options to configure the router.
Installation and Safety Guide 33 Using the CLI to configure the router This section describes how to access the CLI via a switch port in VLAN1 on the AR440S, AR441S and AR442S routers, when the PC and the router are in the same subnet, in order to configure the router. Caution Only one DHCP server should usually be enabled on a network. If you have an existing DHCP server, we recommend disabling either it or the router’s DHCP server.
AR400 Series Router 2. Log in and set the password. The login prompt appears on the terminal or PC. If the login prompt does not appear, press [Enter] two or three times. When the router boots for the first time it automatically creates an account with manager privileges. The account has the login name “manager” and the password is “friend”. Passwords are case sensitive. At the log in prompt, enter the login name and password.
Installation and Safety Guide 35 Connecting Data Cables to AR440S, AR441S, AR442S Connecting the router to your network: 1. Connect to the LAN If you have not already done so, use straight-through Ethernet patch cables to connect the device(s) on your private network (LAN) to the router’s switch port(s). By default, all switch ports are members of VLAN1. 2. Connect to the WAN. Caution If you intend to use a firewall, configure it before you activate the WAN link.
AR400 Series Router System LEDs on AR440S, AR441S, AR442S The LEDs described in the following table show the operational status and port activity for the AR440S, AR441S and AR442S routers. LED State Function Power Green The router is receiving power and the power switch is ON. System Red or amber Lit briefly during router start up, or the router is malfunctioning. Flashing The fan has failed. Off Normal operation.
Installation and Safety Guide 37 Default Configuration on AR415S, AR440S, AR441S, AR442S The default configuration file boot.cfg loads automatically when the router starts up. This file is stored in the router’s flash memory. The AR415S, AR440S, AR441S and AR442S have the following default configuration: #Default configuration file boot.cfg # Set the command help file. (You may have a different help file.) set help=54-275a.HLP # Enable IP and assign an IP address to the default VLAN.
AR400 Series Router Documentation and Tools CD-ROM The Documentation and Tools CD-ROM bundled with each router contains the complete Document Set for your router. The CD-ROM also includes tools for managing your router.
Installation and Safety Guide 39 Connection to mains voltage supply This router is supplied with a power cord has been approved for use and incorporates a moulded plug. It must only be used with the power cord supplied. For continued protection against the risk of fire and shock hazard, replace fuses only with the same type and rating. Telecommunications Interfaces Warning To reduce risk of fire, use only No.26 awg (0.
AR400 Series Router Connection to ISDN network This product is supplied with an approved patch cord for connection to the ISDN Basic Rate Network. Ports for the connection of other apparatus The following interfaces normally operate at Safe Extra Low Voltage (SELV) levels: ■ asynchronous (console) ports ■ Ethernet ports ■ G703 ports ■ synchronous ports Note SELV is a secondary circuit whose voltages do not exceed a safe value under normal operating conditions and under single fault conditions.
Installation and Safety Guide 41 Safety WARNING: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. ELECTRICAL NOTICES WARNING: ELECTRIC SHOCK HAZARD To prevent ELECTRIC shock, do not remove the cover. No user-serviceable parts inside. This unit contains HAZARDOUS VOLTAGES and should only be opened by a trained and qualified technician.
AR400 Series Router Sicherheit WARNUNG: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen. ACHTUNG: GEFÄHRLICHE SPANNUNG Das Gehäuse nicht öffnen. Das Gerät enthält keine vom Benutzer wartbaren Teile. Das Gerät steht unter Hochspannung und darf nur von qualifiziertem technischem Personal geöffnet werden.
Installation and Safety Guide 43 Sikkerhed ADVARSEL: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger. ELEKTRISKE FORHOLDSREGLER ADVARSEL: RISIKO FOR ELEKTRISK STØD For at forebygge ELEKTRISK stød, undlad at åbne apparatet. Der er ingen indre dele, der kan repareres af brugeren. Denne enhed indeholder LIVSFARLIGE STRØMSPÆNDINGER og bør kun åbnes af en uddannet og kvalificeret tekniker.
AR400 Series Router Veiligheid WAARSCHUWING: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen. WAARSCHUWINGEN MET BETREKKING TOT ELEKTRICITEIT WAARSCHUWING: GEVAAR VOOR ELEKTRISCHE SCHOKKEN Verwijder het deksel niet, teneinde ELEKTRISCHE schokken te voorkomen. Binnenin bevinden zich geen onderdelen die door de gebruiker onderhouden kunnen worden.
Installation and Safety Guide 45 Sécurité MISE EN GARDE : dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates. INFORMATION SUR LES RISQUES ÉLECTRIQUES AVERTISSEMENT: DANGER D’ÉLECTROCUTION Pour éviter toute ÉLECTROCUTION, ne pas ôter le revêtement protecteur du matériel. Ce matériel ne contient aucun élément réparable par l’utilisateur.
AR400 Series Router Turvallisuus VAROITUS: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin. SÄHKÖÖN LIITTYVIÄ HUOMAUTUKSIA VAROITUS: SÄHKÖISKUVAARA Estääksesi SÄHKÖISKUN älä poista kantta. Sisällä ei ole käyttäjän huollettavissa olevia osia. Tämä laite sisältää VAARALLISIA JÄNNITTEITÄ ja sen voi avata vain koulutettu ja pätevä teknikko.
Installation and Safety Guide 47 Norme di Sicurezza AVVERTENZA: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati provvedimenti. AVVERTENZE ELETTRICHE ATTENZIONE: PERICOLO DI SCOSSE ELETTRICHE Per evitare SCOSSE ELETTRICHE non asportare il coperchio. Le componenti interne non sono riparabili dall’utente. Questa unità ha TENSIONI PERICOLOSE e va aperta solamente da un tecnico specializzato e qualificato.
AR400 Series Router Sikkerhet ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler. ELEKTRISITET ADVARSEL: FARE FOR ELEKTRISK SJOKK For å unngå ELEKTRISK sjokk, må dekslet ikke tas av. Det finnes ingen deler som brukeren kan reparere på innsiden. Denne enheten inneholder FARLIGE SPENNINGER, og må kun åpnes av en faglig kvalifisert tekniker.
Installation and Safety Guide 49 Segurança AVISO: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas. AVISOS SOBRE CARACTERÍSTICAS ELÉTRICAS ATENÇÃO: PERIGO DE CHOQUE ELÉTRICO Para evitar CHOQUE ELÉTRICO, não retire a tampa. Não contém peças que possam ser consertadas pelo usuário. Este aparelho contém VOLTAGENS PERIGOSAS e só deve ser aberto por um técnico qualificado e treinado.
AR400 Series Router Seguridad ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto. AVISOS ELECTRICOS ADVERTENCIA: PELIGRO DE ELECTROCHOQUE Para evitar un ELECTROCHOQUE, no quite la tapa. No hay ningún componente en el interior al cual puede prestar servicio el usuario. Esta unidad contiene VOLTAJES PELIGROSOS y sólo deberá abrirla un técnico entrenado y calificado.
Installation and Safety Guide 51 Säkerhet VARNING: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder. TILLKÄNNAGIVANDEN BETRÄFFANDE ELEKTRICITETSRISK: RISK FÖR ELEKTRISK STÖTFör att undvika ELEKTRISK stöt, ta ej av locket. Det finns inga delar inuti som behöver underhållas. Denna apparat är under HÖGSPÄNNING och får endast öppnas av en utbildad kvalificerad tekniker.
AR400 Series Router US Federal Communications Commission (FCC) This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the underside of this equipment is a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If requested, this number must be provided to the telephone company. For the AR021U PIC Facility Interface Code 021S5 Service Order Code 6.
Installation and Safety Guide 53 Canadian Department of Communications The Industry Canada label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user’s satisfaction.
AR400 Series Router Emission Compliance Statements STANDARDS: The AR415S, AR440S, AR441S, and AR442S meet the following standards: Category Approval Agency and Requirement Safety UL60950-1 EN60950-1 AS/NZS 60950 Electromagnetic Compliance FCC CFR47 Part 15 Class A EN55022 Class A VCCI Class A AS/NZS CISPR22 Class A Immunity EN55024 Network Interface (where applicable) ISDN Limited Network Protocol Analysis FCC Part 68, Subpart D IC CS-03, Issue 8, Part I and IV TBR3 TBR4 TR048 TIA-968-A PTC 27
Installation and Safety Guide 55 STANDARDS: The AR450S meets the following standards: Category Approval Agency and Requirement Safety UL60950 EN60950 AS/NZS 3260 Electromagnetic Compliance FCC CFR47 Part 15 Class B EN55022 Class B VCCI Class B AS/NZS CISPR22 Class B Immunity EN55024 U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
EC Declaration of Conformity We: ALLIED TELESIS LABS LIMITED 27 NAZARETH AVENUE CHRISTCHURCH 8024 NEW ZEALAND Declare under our sole legal responsibility that the AR400 SERIES ROUTERS is in conformity with the essential requirements of directives: ■ 73/23/EEC Low Voltage Directive incl its amending directive 93/68/EEC ■ 89/336/EEC Electromagnetic Compatibility (EMC) Directive incl its amending directives 92/31/EC, 93/68/EEC and 2004/108/EC ■ 1999/5/EC Radio Equipment and Telecommunications Terminal E