Switches ® AT-3726XL AT-3716XL AT-3714FXL ! Installation Guide PN 613-10766-00 Rev B
Copyright 1998-1999 Allied Telesyn International, Corp. 960 Srewart Drive Suite B, Sunnyvale CA 94086 USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. CentreCom is a registered trademark of Allied Telesyn International, Corp. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn International, Corp.
Electrical Safety and Installation Requirements For AT-3726XL and AT-3716XL Standards: This product meets the following standards U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Electrical Safety and Installation Requirements For AT-3714FXL Standards: This product meets the following standards. Declaration Of Conformity Manufacturers Name: Manufacturers Address: Allied Teleysn International, Corp. 960 Stewart Drive, Suite B Sunnyvale, CA 94086 USA Manufacturers Telephone: 408-730-095 Declares that the product: Fiber Ethernet Switch Model Number: AT-3714FXL This product complies with FCC Part 15B, Class B Limits: This device complies with part 15 of the FCC Rules.
Safety Warnings WARNING: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. " 3 IMPORTANT: Appendix A contains translated safety statements for installing this equipment. When you see the ", go to Appendix A for the translated safety statement in your language. WICHTIG: Anhang A enthält übersetzte Sicherheitshinweise für die Installation dieses Geräts.
Table of Contents Electrical Safety and Installation Requirements .......................................................................................................................iii For AT-3726XL and AT-3716XL ........................................................................................................................................................................iii For AT-3714FXL ...........................................................................................................
Table of Contents Chapter 3 Troubleshooting ...........................................................................................................................................................................................3-1 At the First Sign of a Problem ........................................................................................................................................................................3-1 Network Cabling Problems ................................................
Preface Purpose of This Guide This guide is written for installers and network administrators who are responsible for installing and maintaining the switch. How This Guide is Organized This guide consists of the following sections: Chapter 1, Product Description, describes the features and functions of the switch. Chapter 2, Installing the Switch, describes the procedures for installing the switch. Chapter 3, Troubleshooting, describes how to troubleshoot the switch.
Preface Document Conventions The conventions used in this guide are as follows: Note A note provides additional information. Warning A warning indicates that performing or omitting a specific action may result in bodily injury. Caution A caution indicates that performing or omitting a specific action may result in equipment damage or loss of data. When you see the ", go to Appendix A for the translated safety statement in your language.
Chapter 1 Product Description The AT-3726XL and AT-3716XL are standalone, managed Ethernet switches that provides 24 or 14 10Base-T ports and one built-in 10/100Base-TX port. All ports capable of full- or half-duplex with auto-negotiation or manual configuration on all ports. The AT-3714FXL provides 12 10Base-FL ports with one built-in 100Base-FX (SC). All ports manually configurable for half- or fullduplex.
Product Description AT-3726XL 10BASE-T ETHERNET SWITCH with FAST ETHERNET 100BASE ACCESS MDA 100BASE-TX 10BASE-T 1X B 3X 5X 9X 7X 11X PORT ACTIVITY 13X 15X 17X 19X 21X 23X MIRROR PORT LINK LINK RS-232 TERMINAL PORT STATUS ACTIVITY AT-A20 100BASE-FX/MT A X X 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 FAULT RESET B 2X 4X 6X 10X 8X 12X 14X 16X 18X 20X 22X 24X 13X 15X A POWER X AT-A20 (optional MDA) AT-3716XL 10BASE-T E
AT-3726XL, AT-3716XL, and AT-3714FXL Installation Guide Physical Description The switches have the following major front panel components: # 24 or 14 Ethernet 10Base-T RJ45 ports (AT-3726XL, AT-3716XL); 12 Ethernet 10Base-FL (SC/ST) ports (AT-3714FXL) # Optional MDA - 100Base-X port can be configured either with 10/100Base-TX (RJ45, AT-A10) connector, 100Base-FX (SC, ATA11) connector, 100Base-FX (MT-RJ, AT-A20) connector or 100Base-FX (VF-45, AT-A21) connector # Port Mirroring on 10Base-T RJ45 port # One F
Product Description Hardware Features The switches have the following major hardware features: # 24 or 16 10Base-T ports for the AT-3726XL/AT-3716XL, plus one built-in 10/100Base-TX port capable of full- or half-duplex configurable through auto-negotiation (IEEE 802.3u standard) or manually settleable. # 12 10Base-FL ports (SC/ST) for the AT-3714FXL, capable of fullor half-duplex, manually configurable.
AT-3726XL, AT-3716XL, and AT-3714FXL Installation Guide Network Management Features The switches have the following major network management features: # SNMP Management Information Base (MIB) II, SNMP MIB extensions, Bridging MIB (RFC 1493), and Telnet support deliver comprehensive in-band management # Web-based management # Local Omega, a menu-based management console, provides detailed out-of-band configuration # VLAN by port and 802.
Product Description If this additional delay is not applied, the switch attempts to transmit on an overloaded network, increasing the number of unsuccessful transmission attempts. For detailed information concerning software and management features, refer to the AT- S20 User’s Guide. Mirror Port The switch has a dedicated Mirror port. Administrators can use the Omega software to configure the Mirror port and modes. The Mirror port can monitor traffic on any port, one port at a time.
AT-3726XL, AT-3716XL, and AT-3714FXL Installation Guide Table 1-1 lists the features of the MDAs. For details concerning how to install an adapter, see Chapter 2, Installing a Media Dependent Adapter on page 2-11. Table 1-1 Media Dependent Adapter Features Adapter Supported Cable AT-A10 RJ45 10/100Base-TX RJ45 Ethernet port: auto-negotiated speed and duplex mode 10/100Base-T max.
Product Description RS232 Connector The RS232 connector provides out-of-band management through a VT100 terminal or a terminal emulation program such as HyperTerminal which is included with Microsoft ® Windows’ OS using a straight-through serial cable. Reset Button This recessed button can be activated using the tip of a ball point pen to reset the unit and run the power-on self tests. AC Power Connector The switch has a single power supply, which has autoswitch AC inputs.
Chapter 2 Installing the Switch The AT-3726XL, AT-3716XL, and AT-3714FXL switch is 1.5 Rack Unit (RU) high and can be positioned on a desktop as a standalone unit or rack-mounted in a standard 19-inch rack. Verifying Switch Package Contents Make sure the following hardware components are included in your switch package. If any of the following items are missing or damaged, contact your sales representative.
Installing the Switch Safety Information Refer to Appendix A for translated safety statements in your language. Warning Electric Shock Hazard To prevent ELECTRIC shock, do not remove cover. No user-serviceable parts inside. This unit contains HAZARDOUS VOLTAGES and should only be opened by a trained and qualified technician. To avoid the possibility of ELECTRIC SHOCK disconnect electric power to the product before connecting or disconnecting the LAN cables. "8 Laser Warning Class 1 Laser product.
AT-3726XL, AT-3716XL, and AT-3714FXL Installation Guide Preparing the Site Make sure that you follow common sense installation site requirements and observe the following: # Make sure that the switch’s power is accessible and cables can be easily connected. # Cabling must be away from sources of electrical noise such as radios, transmitters, broadband amplifiers, power lines, and fluorescent fixtures. # Ensure that the air vents on the side and rear of the switch are not restricted.
Installing the Switch Installing the Switch on the Desktop 1. Place the switch on a level, secure surface. 2. Apply power to the switch as follows: Caution The power cord is used as a disconnect device. To de-energize equipment, disconnect the power cord. " 10 Attach the power cord to the unit and plug it in the wall outlet. Verify that the Power LED lights green. See Table 2-1 on 2-6. As power is applied to the switch, the Fault LED flashes as the switch runs through its internal self-testing programs.
AT-3726XL, AT-3716XL, and AT-3714FXL Installation Guide Rack Mounting the Unit Caution Do not use power tools to perform the following installation. To rack mount the unit 1. Remove all cables and power cord from the switch (if previously attached). 2. Remove the snap-on plastic feet, as shown in Figure 2-1. Figure 2-1 Removing the Feet 3. Attach the rack-mounting brackets to each side of the switch, using the 6 flathead screws provided.
Installing the Switch 4. Mount the unit in the rack. 5. Apply power to the unit as follows: Caution Power cord is used as a disconnection device. To de-energise equipment disconnect the power cord. " 10 Attach the power cord to the unit and plug it in the wall outlet. Verify that the Power LED lights green. As power is applied to the switch, the switch runs its own internal testing. See Table 2-1, LEDs.
AT-3726XL, AT-3716XL, and AT-3714FXL Installation Guide Setting Up Terminal for Local Management Using Omega 1. For local management, connect your terminal to the RS232 connector on the switch’s front panel. Use an RS232 DB9 straight-through serial cable. Note The RS232 is for Setup and Diagnostics only. The cable must be disconnected during normal operation to maintain Emissions Compliance. 2. Access your terminal emulator program. Press Return several times to ensure baud configuration (autobaud). 3.
Installing the Switch Switch Default Settings Table 2-2 lists the switch default settings. Table 2-2 Switch Default Settings Settings Default IP Address 0.0.0.0 Subnet Mask 0.0.0.0 Gateway Address 0.0.0.
AT-3726XL, AT-3716XL, and AT-3714FXL Installation Guide Media Dependent Adapters Four types of MDAs can be installed in the switches: either the AT-A10 (RJ45), the AT-A11 (Fiber/SC), the AT-A20 (Fiber/MT) or the AT-A21 (Fiber/VF).
Installing the Switch Media Dependent Adapter Features Table 2-3 lists the MDA features. Table 2-3 Media Dependent Adapter Features Adapter Supported Cable AT-A10 RJ45 10/100Base-TX RJ45 Ethernet port: auto-negotiated speed and duplex mode 10/100Base-T max. segment length: 330 ft (100 m), Category 5 UTP AT-A11 Fiber SC 100Base-FX: multimode SC fiber connector 100Base Ethernet port 100Base-FX: max. segment length 1.25 mi (2 km) for full-duplex, 1351 ft (412 m) for half-duplex; 50/125 and 62.
AT-3726XL, AT-3716XL, and AT-3714FXL Installation Guide Installing a Media Dependent Adapter To install an MDA, do the following: 1. Disconnect the switch’s power cord. 2. Unscrew the 3 flathead Phillips screws on the switch’s blank faceplate and save the faceplate and screws for future use. Caution Make sure the MDA blank panel is attached to the unit if the MDA slot is vacant. 3. Unpack the MDA, making sure to observe ESD precautions.
Installing the Switch 50-pin plug Slot PO RT A 100 BA S E-T X 100AT-A BA 10 SE -TX X Standoff 10B AS 2X Figure 2-5 Connecting the 50-Pin Plug 6. Secure the MDA to the front of the switch with the 3 flathead Phillips screws that came with the MDA package. 7. Apply power to the unit as follows: Caution Power cord is used as a disconnection device. To de-energise equipment disconnect the power cord. " 10 Re-attach the power cord to the unit and plug it in the wall outlet.
Chapter 3 Troubleshooting At the First Sign of a Problem Perform the following tasks when you first become aware of a problem with the switch: # Make sure the power cord is securely connected and the power voltage is not fluctuating. # Check the data cables for secure connections and make sure the device at the other end of a connection is operational. # Press the Reset button so the switch can run self-diagnostics. Use Omega to run diagnostics and read statistics.
Troubleshooting Network Cabling Problems If you have 100Base-TX (Fast Ethernet), some network problems may be related to exceeding cabling distances. Refer to the standard IEEE 802.3u, Clause 29.3.1.2 on Worst Case Path Delay Value. This document specifies that the collision domain diameter must be within the following limits: # Under 330 ft (100 m) for TX cabling # Under 1331.
AT-3726XL, AT-3716XL, and AT-3714FXL Installation Guide Contacting Technical Support Provide Technical Support with the following information: # Switch model and serial number # Software version number # Description of the problem See Allied Telesyn’s website at www.alliedtelesyn.com for a list of worldwide Allied Telesyn locations.
Troubleshooting How the Switch Reports Problems The switch detects and processes errors as follows: # The LEDs indicate problems with the port and power. Table 3-1 list and describes the switch LEDs. # In a TCP/IP environment, if you have configured the software correctly, the management software triggers an SNMP trap message. As a result, the software then sends traps to alert the network manager when a trigger occurs.
AT-3726XL, AT-3716XL, and AT-3714FXL Installation Guide Common Problems This section lists the common switch problems and the recommended actions to correct these problems. Port Activity LED ON any Port is OFF This may indicate: # A loose data cable. # The device at the other end of the connection is turned OFF. # The port is disabled through the software. Perform the following steps in sequence; you need not proceed to the next step if the problem is resolved: 1. Make sure the data cables are secure. 2.
Troubleshooting Power LED is OFF If there is no power to the switch, it cannot function. A Power LED that is OFF may indicate: # A loose power cord. # Power supply failure, malfunction or loss of power to the power supply. # A power supply voltage is below acceptable levels. # A high switch temperature due to fan failure or ambient temperature extreme. Perform the following steps in sequence; you need not proceed to the next step if the problem is resolved: 1.
AT-3726XL, AT-3716XL, and AT-3714FXL Installation Guide Fault LED is ON This might indicate problems with the network management software, such as: # Unsuccessful software downloads # Loose RS232 interface connection Perform the following steps in sequence; you need not proceed to the next step if the problem is resolved: 1. Reset the switch either by: — Pressing the Reset button on the front panel, or — Selecting System Administration>Reset and restart the system from Omega, if you can. 2.
Chapter 4 Switch Configurations Standalone Switch Configuration Figure 4-4 and Figure 4-2 show the AT-3726XL and AT-3714FXL Switch respectively, used as a standalone switch for a group of heavy traffic users in a large corporate network. Switching is brought to the desktop with a single end-station per switch port. A local server is connected to the 100 Mbps Fast Ethernet port.
Switch Configurations AT-A11 10BASE-FL ETHERNET SWITCH with FAST ETHERNET 100BASE ACCESS MDA 10BASE-FL 100BASE-FX 1 3 5 7 9 PORT ACTIVITY 11 MIRROR PORT LINK B LINK RS-232 TERMINAL PORT STATUS ACTIVITY AT-A11 A 100BASE-FX/SC TX RX TX RX TX RX TX RX TX RX TX 1 3 5 7 9 11 2 4 6 8 10 12 RX FAULT TX RX RESET B TX RX 2 4 6 8 10 A 12 POWER X AT-3714FXL 100Base-FX Full-duplex Server Workstation Uplink to corporate LAN using MDA Workstation Workstation
AT-3726XL, AT-3716XL and AT-3714FXL Installation Guide Workgroup Switch Configuration Figure 4-3 and Figure 4-4 show how cascaded AT-3726XLs and AT-3714FXLs respectively, fit into a large corporate network with a Fast Ethernet infrastructure. A switch is located on each floor and servers are centralized in one room.
Switch Configurations AT-3606F Hub AT-3714FXL 10BASE-T ETHERNET SWITCH with FAST ETHERNET 100BASE ACCESS MDA 100BASE-TX 10BASE-T B PORT ACTIVITY 1X 3X 5X 7X 9X 11X 13X 15X 2X 4X 6X 8X 10X 12X 14X 16X MIRROR PORT LINK LINK RS-232 TERMINAL PORT STATUS ACTIVITY 3701 100BASE-TX A X X 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 FAULT RESET B A POWER X AT-3606F Hub AT-3714FXL 10BASE-T ETHERNET SWITCH with FAST ETHERNET 100BASE ACCESS MDA 100BASE-TX 10BASE-T B
Appendix A Translated Safety Information IMPORTANT: This appendix contains multiple-language translations for the safety statements in this guide WICHTIG: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. VIGTIGT: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. BELANGRIJK: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Translated Safety Information " 1a RFI Emission EN55022 Class A (AT-3726XL, AT-3716XL) " 1b RFI Emission EN55022 Class B (AT-3714FXL) "2 Immunity EN50082-1 (includes all switches) "3 WARNING: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
AT-3726XL, AT-3716XL, and AT-3714FXL Installation Guide "9 GEFAHR DURCH BLITZSCHLAG GEFAHR: Keine Arbeiten am Gerät oder an den Kabeln während eines Gewitters ausführen. " 10 VORSICHT: DAS NETZKABEL DIENT ZUM TRENNEN DER STROMVERSORGUNG. ZUR TRENNUNG VOM NETZ, KABEL AUS DER STECKDOSE ZIEHEN. AUTOMATISCHE SPANNUNGSEINSTELLUNG Dieses Gerät stellt sich automatisch auf die auf dem Etikett aufgeführten Spannungswerte ein. " 11 GERÄTE DER KLASSE 1 DIESE GERÄTE MÜSSEN GEERDET SEIN.
Translated Safety Information ADVARSEL: Betjen kun de installerede produkter i den HORISONTALE position (vandret). BETJEN DEM IKKE I DEN VERTIKALE POSITION (lodret). " 13 ADVARSEL: Ventilationsåbninger må ikke blokeres og skal have fri adgang til den omgivende luft i rummet for afkøling. " 14 BETJENINGSTEMPERATUR Dette apparat er konstrueret til en omgivende temperatur på maksimum 40 grader C.
AT-3726XL, AT-3716XL, and AT-3714FXL Installation Guide "5 Laser "6 ATTENTION Producit laser di classe 1. "7 ATTENTION Ne pas fixer le faisceau des yeux. "8 INFORMATION SUR LES RISQUES ÉLECTRIQUES AVERTISSEMENT : DANGER D’ÉLECTROCUTION Pour éviter toute ÉLECTROCUTION, ne pas ôter le revêtement protecteur du matériel. Ce matériel ne contient aucun élément réparable par l’utilisateur. Il comprend des TENSIONS DANGEREUSES et ne doit être ouvert que par un technicien dûment qualifié.
Translated Safety Information SÄHKÖ —AUTOMAATTINEN JÄNNITTEENSÄÄTÖ Tämä tuote säätää automaattisesti mihin tahansa jännitteeseen ohjetarrassa annettujen arvojen välillä. " 11 SÄHKÖ—TYYPPILUOKAN 1 LAITTEET TÄMÄ LAITE TÄYTYY MAADOITTAA. Pistoke täytyy liittää kunnollisesti maadoitettuun pistorasiaan. Virheellisesti johdotettu pistorasia voi altistaa metalliosat vaarallisille jännitteille.
AT-3726XL, AT-3716XL, and AT-3714FXL Installation Guide " 15 TUTTI I PAESI: installare il prodotto in conformità delle vigenti normative elettriche nazionali. " 1a RFI stråling EN55022 Klasse A (AT-3726XL, AT-3716XL) " 1b RFI stråling EN55022 Klasse B (AT-3714FXL) "2 Immunitet EN50082-1 "3 ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler.
Translated Safety Information ELÉTRICO, desconecte o aparelho da fonte de energia elétrica antes de conectar e desconectar os cabos da LAN. "9 PERIGO DE CHOQUE CAUSADO POR RAIO PERIGO: NÃO TRABALHE no equipamento ou nos CABOS durante períodos suscetíveis a QUEDAS DE RAIO. " 10 CUIDADO: O CABO DE ALIMENTAÇÃO É UTILIZADO COMO UM DISPOSITIVO DE DESCONEXÃO. PARA DESELETRIFICAR O EQUIPAMENTO, desconecte o cabo de ALIMENTAÇÃO.
AT-3726XL, AT-3716XL, and AT-3714FXL Installation Guide enchufe a tierra debidamente instalado. Un enchufe que no está correctamente instalado podría ocasionar tensiones peligrosas en las partes metálicas que están expuestas.
Appendix B Technical Specifications Table B-1 lists the technical specifications for the AT-3726XL, AT-3716XL, and AT-3714FXL Switch. Table B-3 AT-3726XL, AT-3716XL, and AT-3714FXL Technical Specifications Physical Specifications Dimensions (H x W x D) Base unit (fully loaded) Required ventilation on all sides Weight 2.5 in x 17.33 in x 12.60 in 10 lbs, 13 oz (4.9 kg) (6.35 cm x 44.02 cm x 32.00 cm) 7.
Technical Specifications Table B-2 RJ45 Pin Assignments Pin Number Function 1 RD+ 2 RD- 3 TD+ 4 Unused 5 Unused 6 TD- 7 Unused 8 Unused Media Dependent Adapter Cabling Distances Table B-3 lists the maximum cable distances for the AT-3726XL, AT-3716XL, and AT-3714FXL switch Media Dependent Adapter (MDA). Table B-3 MDA Maximum Cable Distances MDA B-2 Ethernet Type Maximum Distance AT-A10 RJ45 (10/100Base) 330 ft (100 m), twisted pair Category 5 UTP AT-A11 SC (100Base) 1.
Index media dependent adapter (MDA) 1-1 Microsoft Windows VTERM 1-8 Mirror port 1-6 Numerics 1.