User guide
Table Of Contents
- installation guide
- Electrical Safety and Installation Requirements fo...
- STANDARDS: This product meets the following standa...
- RADIATED ENERGY
- Note: This equipment has been tested and found to ...
- Note: Modifications or changes not expressly appro...
- This Class A digital apparatus meets all requireme...
- Cet appareil numérique de la classe A respecte tou...
- RFI Emission EN55022 Class A
- Immunity EN50082-1
- WICHTIG: Für den Betrieb dieses Gerätes ist die Ei...
- VIGTIGT: Dette udstyr skal bruges i overensstemmel...
- BELANGRIJK: Dit apparaat moet in overeenstemming m...
- IMPORTANT : Cet équipement doit être utilisé confo...
- TÄRKEÄÄ: Tätä laitetta on käytettävä turvaohjeiden...
- IMPORTANTE: questa apparecchiatura deve essere uti...
- VIKTIG: Dette utstyret skal brukes i samsvar med s...
- IMPORTANTE: Este equipamento tem que ser operado s...
- IMPORTANTE: La operación de este equipo debe lleva...
- OBS! Alla nödvändiga försiktighetsåtgärder måste v...
- Electrical Safety and Installation Requirements fo...
- STANDARDS: This product meets the following standa...
- Manufacturers Name: Allied Teleysn International, ...
- Manufacturers Telephone: 408-730-0950 Declares tha...
- Complies with FCC Part 15B, Class B Limits:
- This device complies with part 15 of the FCC Rules...
- This equipment has been tested and found to comply...
- - Reorient or relocate the receiving antenna.
- - Increase the separation between the equipment an...
- - Connect the equipment into an outlet on a circui...
- - Consult the dealer or an experienced radio/TV te...
- Changes and modifications not expressly approved b...
- This Class B digital apparatus meets all requireme...
- Cet appareil numérique de la classe B respecte tou...
- RFI Emission EN55022 Class B
- Immunity EN50082-1
- WICHTIG: Für den Betrieb dieses Gerätes ist die Ei...
- VIGTIGT: Dette udstyr skal bruges i overensstemmel...
- BELANGRIJK: Dit apparaat moet in overeenstemming m...
- IMPORTANT : Cet équipement doit être utilisé confo...
- TÄRKEÄÄ: Tätä laitetta on käytettävä turvaohjeiden...
- IMPORTANTE: questa apparecchiatura deve essere uti...
- VIKTIG: Dette utstyret skal brukes i samsvar med s...
- IMPORTANTE: Este equipamento tem que ser operado s...
- IMPORTANTE: La operación de este equipo debe lleva...
- OBS! Alla nödvändiga försiktighetsåtgärder måste v...
- Table of Contents
- Preface
- AT-3714F, AT-3726 Hardware Description
- Installing the Switch
- Verifying Switch Package Contents
- Safety Information
- Preparing the Site
- Rack Mounting the Unit
- Media Dependent Adapters
- Figure23 AT-3701 and AT-3701F/SC MDA Front Pan...
- Verifying Package Contents
- Media Dependent Adapter Features
- Table23 Media Dependent Adapter Features
- Installing a Media Dependent Adapter
- 1. Disconnect the switch’s power cord.
- 2. Unscrew the three Phillips head screws on the b...
- 3. The standoff on the MDA serves as a guide to sl...
- 4. Slide the MDA into its empty slot making sure t...
- 5. Attach the female 50-pin female connector to it...
- Figure24 Guiding the MDA (AT-3701) Standoff in...
- Figure25 Connecting the 50-Pin Female Connecto...
- MDA LEDs
- Installing a Media Dependent Adapter
- Table24 Media Dependent Adapter LEDs
- Troubleshooting
- Switch Configurations
- AppendixA
- AppendixB

Installing the Switch
2-8
Switch Default
Settings
Table 2-2 Switch Default Settings
Settings Default
IP Address 0.0.0.0
Subnet Mask 0.0.0.0
Gateway Address 0.0.0.0
Get community string Public
Set community string Private
Trap community string Public
Port mirroring state Disabled
Spanning Tree Protocol Enabled
Telnet Access Enabled
System Name None
Password (Omega) No password assigned
Download Password ATS20
Port Priority 128
Port Path Cost 100
Auto-negotiate/Half Duplex/Full Duplex Auto-negotiate (AT-3726)
Half Duplex (AT-3714F)
Spanning Tree Priority 32768
Active Aging Time 300 seconds
Hello Time 2 seconds
Transmit Pacing Disabled
Bridge Identifier (STP) 32768 (bridge priority)
Port Priority (STP) 128
Port Cost (STP) 100 for 10 Mbps ports
10 for 100 Mbps ports
Store and Forward or, Cut-Through Fragment-Free Store-and-Forward
Domain Name None
Timeout 5 min.