AT-8500 Series Layer 2+ Fast Ethernet Switches ® AT-8516F/SC AT-8524M AT-8524POE AT-8550GB AT-8550SP Installation Guide PN 613-50484-00 Rev C
Copyright © 2004 Allied Telesyn, Inc. 960 Stewart Drive Suite B, Sunnyvale, CA 94085 USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn, Inc. Microsoft is a registered trademark of Microsoft Corporation, Netscape Navigator is a registered trademark of Netscape Communications Corporation.
Electrical Safety and Emission Statement Standards: This product meets the following standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Table of Contents Electrical Safety and Emission Statement ............................................................................................................................................... 3 Preface ...................................................................................................................................................................................................................... 7 How This Guide is Organized .....................................................
100Base-FX Fiber Optic Ports ..........................................................................................................................................................................22 Type of Connector........................................................................................................................................................................................22 Speed ....................................................................................................
Table of Contents Standards ............................................................................................................................................................................................................... 81 SNMP Support ...................................................................................................................................................................................................... 82 RJ-45 Twisted Pair Port Pinouts .........................
Preface This guide contains the hardware installation instructions for your managed, Layer 2+ AT-8500 Series Fast Ethernet Switch. How This Guide is Organized This manual contains the following chapters and appendices: Chapter 1, Overview, describes the features and components of the switch. Chapter 2, Installation, contains the installation instructions. Chapter 3, Troubleshooting, provides information on how to resolve problems that might occur with the switch.
Preface Document Conventions This document uses the following conventions: Note Notes provide additional information. Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data. Warning Warnings inform you that performing or omitting a specific action may result in bodily injury.
AT-8500 Series Fast Ethernet Switch Installation Guide Where to Find Web-based Guides The installation and user guides for all Allied Telesyn products are available in portable document format (PDF) from the Allied Telesyn web site at www.alliedtelesyn.com. You can view the documents online or download them onto a local workstation or server. Once you have installed your AT-8500 Series Switch, refer to following manuals for instructions on how to manage and configure the unit.
Preface Contacting Allied Telesyn This section provides Allied Telesyn contact information for technical support as well as sales and corporate information. Online Support You can request technical support online by accessing the Allied Telesyn Knowledge Base from the following web site: www.alliedtelesyn.com/kb. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
Chapter 1 Overview The AT-8500 Series Switches are managed, Layer 2+ Fast Ethernet switches. These switches are designed to simplify the task of creating or expanding an Ethernet or Fast Ethernet network. Table 1 lists the basic model configurations. Table 1 Model Configurations Model Configuration AT-8516F/SC 16 100Base-FX ports with dual SC connectors plus two expansion slots for optional fiber optic and twisted pair port expansion modules.
Overview Model Descriptions AT-8516F/SC The AT-8516F/SC switch has 16 100Base-FX fiber optic ports with dual SC connectors. The ports operate at 100 Mbps, half- or full-duplex mode, and have a maximum operating distance of 2 kilometers (1.24 miles) or 412 meters (1,360 feet), depending on the duplex mode, using 50/125 or 62.5/125 micron (core/cladding) multimode fiber optic cable. Figure 1 illustrates the front panel of the AT-8516F/SC switch.
AT-8500 Series Fast Ethernet Switch Installation Guide AT-8524M The AT-8524M switch has 24 10/100Base-TX twisted pair ports and two module expansion slots. The twisted pair ports feature RJ-45 connectors and have a maximum operating distance of 100 meters (328 feet) using Category 3 or better 100 ohm twisted pair cable for 10Base-T operation and Category 5 or 5E 100 ohm twisted pair cable for 100Base-TX operation.
Overview AT-8524POE The AT-8524POE switch has 24 10/100Base-TX ports with Power over Ethernet (PoE) capability. (For a description of this feature, refer to Power Over Ethernet on page 23.) The ports feature RJ-45 connectors and have a maximum operating distance of 100 meters (328 feet) using twisted pair cable. The ports, when not using PoE, can use Category 3 or better 100 ohm twisted pair cable for 10Base-T operation and Category 5 or 5E 100 ohm twisted pair cable for 100Base-TX operation.
AT-8500 Series Fast Ethernet Switch Installation Guide AT-8550GB The AT-8550GB switch has 48 10/100Base-TX twisted pair ports, capable of operating at either 10 or 100 Mbps, with RJ-45 connectors. These ports have a maximum operating distance of 100 meters (328 feet) using Category 3 or better 100 ohm twisted pair cable for 10Base-T operation and Category 5 or 5E 100 ohm twisted pair cable for 100Base-TX operation.
Overview AT-8550SP The AT-8550SP switch has 48 10/100Base-TX twisted pair ports with RJ-45 connectors. The ports have a maximum operating distance of 100 meters (328 feet) using Category 3 or better 100 ohm twisted pair cable for 10Base-T operation and Category 5 or 5E 100 ohm twisted pair cable for 100Base-TX operation. The switch also features two 10/100/1000Base-T twisted pair ports, labelled Ports 49R and 50R.
AT-8500 Series Fast Ethernet Switch Installation Guide Hardware Features The following sections describe these hardware features of the AT-8500 Series Fast Ethernet Switches: 10/100Base-TX Twisted Pair Ports on page 18 10/100/1000Base-T Twisted Pair Ports on page 20 100Base-FX Fiber Optic Ports on page 22 Power Over Ethernet on page 23 GBIC and SFP Expansion Slots on page 26 Module Expansion Slots on page 27 Twisted Pair Port LEDs and the LED Mode Select Button on page 28 Fiber Optic Port L
Overview 10/100Base-TX Twisted Pair Ports This section applies to the AT-8524M, AT-8524POE, AT-8550GB, and AT-8550SP switches. Type of Connector The 10/100Base-TX twisted pair ports feature 8-pin RJ-45 connectors. Only four of the pins are used when a port is operating at 10 or 100 Mbps Speed The twisted pair ports are 10/100Base-TX compliant and are capable of 10 megabits per second (Mbps) or 100 Mbps speeds. You can set the port speed manually or, because the ports are IEEE 802.
AT-8500 Series Fast Ethernet Switch Installation Guide Maximum Distance Each twisted pair port has a maximum operating distance of 100 meters (328 feet). Type of Cabling For 10 Mbps operation, Category 3 or better 100 ohm shielded or unshielded twisted pair cabling is required. For 100 Mbps operation, Category 5 or Enhanced Category 5 (5E) 100 ohm shielded or unshielded twisted pair cabling is required. Auto-MDI/ MDI-X The twisted pair ports are auto-MDI/MDI-X.
Overview 10/100/1000Base-T Twisted Pair Ports This section applies to Port 49R and Port 50R on the AT-8550GB and AT-8550SP switches. Type of Connector Speed The ports have 8-pin RJ-45 connectors. The ports use four pins when operating at 10 or 100 Mbps and all eight pins when operating at 1000 Mbps. The ports can operate at 10, 100, or 1000 Mbps. The speed is set automatically through Auto-Negotiation or you can set the speed to 10 or 100 Mbps manually through the management software.
AT-8500 Series Fast Ethernet Switch Installation Guide Auto-MDI/ MDI-X The ports are auto-MDI/MDI-X. They automatically configure themselves as either MDI or MDI-X. This feature allows you to use a straight-through twisted pair cable to connect any type of device to a port. Note The auto-MDI/MDI-X feature on a 10/100/1000Base-T port is functional only when the port is set to Auto-Negotiation. If you disable Auto-Negotiation and set the port’s speed and duplex mode manually, the port defaults to MDI-X.
Overview 100Base-FX Fiber Optic Ports This section applies to the AT-8516F/SC switch. Type of Connector Speed Duplex Mode Maximum Distance Type of Cable The fiber optic ports on the AT-8516F/SC switch have dual SC connectors. The fiber optic ports have a fixed operating speed of 100 megabits per second (Mbps). The speed cannot be changed. The fiber optic ports can operate in either half- or full-duplex mode.
AT-8500 Series Fast Ethernet Switch Installation Guide Power Over Ethernet The following discussion applies only to the AT-8524POE switch. The twisted pair ports on the AT-8524POE switch offer the same features and functionality as the twisted pair ports on the other switches in the series. As such, they can operate at 10 or 100 Mbps, feature AutoNegotiation and Auto-MDI/MDI-X, and so forth. But they do have an importance difference in that they also feature Power over Ethernet (PoE).
Overview A port on the switch connected to a powered device can supply up to 15.4 watts of power to the device, while at the same time furnishing standard 10/100 Mbps Ethernet functionality. A port connected to a network node that is not a powered device (that is, a device that receives its power from another power source) functions as a regular Ethernet port, without PoE. The PoE feature remains enabled on the port but no power is delivered to the device.
AT-8500 Series Fast Ethernet Switch Installation Guide You can, using the AT-S62 management software, enable or disable PoE on a per-port basis. You can also reduce the maximum amount of power a port can receive, from the maximum of 15.4 W. However, configuring PoE on an AT-8524POE switch will probably be unnecessary. As already mentioned, the power supply in the switch can provide enough power to meet the needs of all 24 base ports, even if all are connected to power devices requiring the maximum of 15.
Overview GBIC and SFP Expansion Slots The AT-8550GB and AT-8550SP switches have two GBIC expansion slots and two SFP expansion slots, respectively. The slots are labelled Port 49 and Port 50. Each slot can accommodate one optional fiber optic Gigabit Interface Converter (GBIC) Ethernet module or Small Form-factor Pluggable (SPF) module, also referred to as a mini-GBIC. These modules are a fast and easy way for you to add an 1000 Mbps fiber optic port to your Fast Ethernet switch.
AT-8500 Series Fast Ethernet Switch Installation Guide Module Expansion Slots The AT-8516F/SC, AT-8524M, and AT-8524POE switches have two expansion slots. Each slot can accommodate an expansion module. You can use the slots to add 100Base and 1000Base fiber optic and twisted pair ports to the switch. Note For a list of the Allied Telesyn expansion modules supported by the switches, contact your Allied Telesyn sales representative or refer to our web site at: www.alliedtelesyn.com.
Overview Twisted Pair Port LEDs and the LED Mode Select Button This section applies to the AT-8524M, AT-8524POE, AT-8550GB, and AT-8550SP switches. The port LEDs on the front panel display port status information. Each port has two LEDs. One of the LEDs displays the status of the link between a port and its end node. The second LED, labeled MODE, displays a variety of status information, depending on the switch model.
AT-8500 Series Fast Ethernet Switch Installation Guide Table 2 LEDs for the 10/100Base-TX Twisted Pair Ports on the AT-8524M, AT-8550GB, and AT-8550SP Switches LED State Description Mode - FULL OFF Indicates that the port is operating in halfduplex mode. Green Indicates that the port is operating in fullduplex mode. MODE - FDX AT-8550GB and AT-8550SP) OFF Indicates that the port is operating in halfduplex mode. Green Indicates that the port is operating in fullduplex mode.
Overview Table 3 LEDs for Ports 49R and 50R on the AT-8550GB and AT-8550SP Switches LED State Description Mode - FDX OFF Indicates that the port is operating in halfduplex mode. Green Indicates that the port is operating in fullduplex mode. OFF Indicates that there is no activity on the port. Flashing Green Indicates that the port is transmitting and/ or receiving data packets. Mode - ACT Table 4 describes the LEDs for the 10/100Base-TX twisted pair ports on the AT-8524POE switch.
AT-8500 Series Fast Ethernet Switch Installation Guide Table 4 LEDs for the 10/100Base-TX Twisted Pair Ports on the AT-8524POE Switch LED State Description Mode - DC OFF Indicates that the port has not established a valid link with its end node. Steady Green Indicates that the port is operating in full duplex mode. Steady Amber Indicates that the port is operating in half duplex mode.
Overview Fiber Optic Port LEDs This section applies to the AT-8516F/SC switch. The fiber optic ports on an AT-8516F/SC switch have two LEDs, labeled L/A and D/C. The LEDs are defined in Table 5. Table 5 LEDs for the Fiber Optic Ports on the AT-8516F/SC Switch LED State Description L/A OFF Indicates no link has been established between the port and the end node. Green Indicates a valid link exists between the port and the end node.
AT-8500 Series Fast Ethernet Switch Installation Guide GBIC and SFP Expansion Slot LEDs The GBIC and SFP slots on the AT-8550GB and AT-8550SP switches, respectively, have two LEDs. The LEDs display the operating status of the fiber optic port. Use the Mode Select button on the switch to toggle the status information displayed by the MODE LED. The LEDs are defined in Table 6.
Overview System LEDs The system LEDs on the front panel display general status information, as described in Table 7. Table 7 System LEDs LED State Description FAULT or FLT OFF Indicates normal operation. Red Indicates that the management software is saving a change to its configuration. The LED goes off once the configuration has been saved. If the FAULT LED remains on, the switch or management software may have experienced a malfunction.
AT-8500 Series Fast Ethernet Switch Installation Guide RS-232 Terminal Port You can use the RS-232 terminal port to establish a local (out-of-band) management session with the switch and to configure the switch’s operating parameters. You establish a local management session with the switch by connecting either a terminal or a personal computer with a terminal emulation program to the port. Note You are not required to manage an AT-8500 Series switch.
Overview RPS Connector The RPS connector on the back panel of the switch connects to the optional AT-RPS3004 redundant power supply unit, shown in Figure 7. The unit can provide power to the switch in the event the switch’s internal power supply should fail. The AT-RPS3004 redundant external power supply comes with one preinstalled AT-PWR3004 Power Module and has three empty slots for additional power modules.
AT-8500 Series Fast Ethernet Switch Installation Guide AC Power Connector The switch has a single AC power supply socket on the back panel, which has autoswitch AC inputs. To power the switch on or off, you connect or disconnect the power cord. Refer to Technical Specifications on page 77 for the input voltage range.
Overview DC Power Connector Some models of the AT-8500 Series switch are offered with a DC terminal block on the back panel instead of an AC socket, for those network installations that require DC equipment. Refer to Technical Specifications on page 77, for the input voltage range and Wiring a DC Powered Unit on page 66, for instructions on how to wire a DC powered unit.
AT-8500 Series Fast Ethernet Switch Installation Guide A Few Basics about Ethernet Switching An Ethernet switch interconnects network devices, such as workstations, printers, routers, and other Ethernet switches, so that they can communicate with each other by sending and receiving Ethernet frames. MAC Address Table Every hardware device in your network has a MAC address and each MAC address is unique. The address is assigned to a device by the device’s manufacturer.
Overview Duplex Mode Duplex mode refers to the manner in which an end node receives and transmits data. If an end node can receive or transmit data, but not both simultaneously, the end node is operating in what is referred to as halfduplex mode. If an end node can both receive and transmit data simultaneously, the end node is said to be operating in full-duplex mode.
AT-8500 Series Fast Ethernet Switch Installation Guide Store and Forward Backpressure and Flow Control These Fast Ethernet switches use store and forward as the method for receiving and transmitting frames. When an Ethernet frame is received on a switch port, the switch does not retransmit the frame out the destination port until it has received the entire frame and stored the frame in a port buffer. It then examines the frame to determine if it is a valid frame.
Overview Network Topologies This section illustrates several of the network topologies you can create with the AT-8500 Series Fast Ethernet switch. Power Workgroup Topology The topology shown in Figure 8 is commonly referred to as a power workgroup topology. Each workstation or end node is connected directly to a port on an AT-8524M Fast Ethernet Switch. This provides each end node with a dedicated data link to the switch for best performance and reliability.
AT-8500 Series Fast Ethernet Switch Installation Guide Collapsed Backbone Topology In the topology illustrated in Figure 9, an AT-8524M Fast Ethernet Switch connects together 10/100 Mbps Ethernet hubs. This type of topology is often referred to as a collapsed backbone topology. The switch functions as the focal point of the network by acting as a bridge between the different workgroups.
Overview Mixed Topology You can always combine topologies as well as build a larger network by connecting different switches together. If the switches are within 100 meters (328 feet) of each other, you can use the twisted pair ports. If the switches are further apart, then you can use fiber optic ports. Figure 10 illustrates a network of three AT-8524M Fast Ethernet switches. The workstations and servers on the network are connected either directly to a switch or indirectly through an Ethernet hub.
Chapter 2 Installation This chapter contains the installation procedures for the switch.
Installation Reviewing Safety Precautions Please review the following safety precautions before you begin to install the switch or any of its components. Refer to Translated Electrical Safety and Emission Information on page 92 for translated safety statements in your language. (The laser warnings apply only to Fast Ethernet switches and expansion modules that feature a fiber optic port.) Laser Class 1 laser product. 6 Laser Do not stare into the laser beam.
AT-8500 Series Fast Ethernet Switch Installation Guide Selecting a Site for the Switch Observe the following requirements when choosing a site for your switch: If you plan to install the switch in an equipment rack, check to be sure that the rack is safely secured and that it will not tip over. Devices in a rack should be installed starting at the bottom, with the heavier devices near the bottom of the rack. If you are installing the switch on a table, be sure that the table is level and secure.
Installation Planning the Installation Table 8 contains the cabling specifications for the twisted pair ports.
AT-8500 Series Fast Ethernet Switch Installation Guide Note The 10/100/1000Base-T ports, Ports 49R and 50R, on the AT-8550GB and AT-8550SP switches can operate at 1000 Mbps only when set to Auto-Negotiation, which is the default setting. You cannot manually set these ports to 1000 Mbps. Table 9 contains the cabling specifications for the fiber optic ports on an AT-8516F/SC switch.
Installation Unpacking the Switch To unpack the switch, perform the following procedure: 1. Remove all components from the shipping package. Note Store the packaging material in a safe location. You must use the original shipping material if you need to return the unit to Allied Telesyn. 2. Place the switch on a level, secure surface. 3. Make sure the following hardware components are included in your switch package.
AT-8500 Series Fast Ethernet Switch Installation Guide Installing the Switch in a Rack The switch comes with two brackets for mounting the unit in a rack. The brackets can be attached to the chassis four ways. You can install the chassis so that it is flush with the front of the rack or so that it extends forward from the rack. Figure 11 illustrates the different ways that you can install the brackets and how much the chassis extends from the front of the rack.
Installation Perform the following procedure to install the switch in a standard 19-inch rack. If you are not installing the switch in a rack, proceed to Installing an Optional GBIC Module on page 56. 1. Place the unit upside down on a level, secure surface. 2. Using a flat-head screwdriver, remove the snap-on plastic feet from the bottom of the switch, as shown in Figure 12. Figure 12 Removing the Feet 3. Turn the switch over. 4.
AT-8500 Series Fast Ethernet Switch Installation Guide Installing an Optional Expansion or Stacking Module For the AT-8516F/SC, AT-8524M, and AT-8524POE This section describes how to install an optional expansion or stacking module in the switch. Note The modules can be hot-swapped; you do not have to power off a switch to install these options. To install a module, follow these steps: 1. Unpack the module from its shipping container and store the packaging material in a safe location.
Installation Note If removing a module, store the device in an antistatic bag or immediately install it in another switch. Figure 13 Removing the Expansion Slot Faceplate 5. Pull the faceplate straight out of the slot. Keep the faceplate in a safe area in case you need to reinstall it. The faceplate keeps any dust from getting into the switch and maintains proper airflow if the slot remains empty. 6.
AT-8500 Series Fast Ethernet Switch Installation Guide 7. Using a Phillips screwdriver, tighten the installation screws found on the module faceplate, as shown in Figure 15. AT-A4 6 LINK 10 100 10 /10 0 1000 FULL DUPL EX /1000 BASE -T ACTIVI TY Figure 15 Tightening the Module Installation Screws Caution Always use the installation screws to secure the module to the switch. Leaving a module partially seated may cause the system to halt and subsequently crash.
Installation Installing an Optional GBIC Module For the AT-8550GB To install an optional GBIC module in an AT-8550GB Switch, perform the following procedure: Note A GBIC module can be hot-swapped; you do not have to power off a switch to install it. 1. Unpack the GBIC module from its shipping container and store the packaging material in a safe location. Note You must use the original shipping material if you need to return the module to Allied Telesyn.
AT-8500 Series Fast Ethernet Switch Installation Guide ❑ The most common source of contaminants in the optical bore is debris picked up on the ferrules of the optical connectors, as shown in Figure 16. Use an alcohol swab or wipe to clean the ferrules of the optical connector. Ferrule Bore Figure 16 Optical Bore and Ferrule of GBIC Module Note Unnecessary removal and insertion of a GBIC can lead to premature failure. 4.
Installation Installing an Optional SFP Module For the AT-8550SP To install an optional SFP module in an AT-8550SP switch, perform the following procedure: Note A SFP module can be hot-swapped; you do not have to power off a switch to install it. 1. Unpack the SFP module from its shipping container and store the packaging material in a safe location. Note You must use the original shipping material if you need to return the module to Allied Telesyn.
AT-8500 Series Fast Ethernet Switch Installation Guide ❑ The most common source of contaminants in the optical bore is debris picked up on the ferrules of the optical connectors. Use an alcohol swab or wipe to clean the ferrules of the optical connector. Note Unnecessary removal and insertion of a SFP module can lead to premature failure. 4. Slide the SFP module, with the label side up, into an SFP expansion slot on the switch. The SFP module can be installed in either slot.
Installation Cabling and Powering On the Switch Perform the following procedure to connect the data cables to the switch ports and to apply power to the switch. 1. If your AT-8500 Series switch has twisted pair ports, connect the twisted pair data cables to the RJ-45 ports on the switch, as shown in Figure 18.
AT-8500 Series Fast Ethernet Switch Installation Guide 2. ❑ If you are creating a port trunk, do not connect the cables of the trunk to the switch until you after have configured the trunk using the switch’s management software. Connecting the trunk cables to the switch before you have configured the software will result in a data loop, which can adversely affect network performance.
Installation 3. Attach the fiber optic data cables to the fiber optic ports, as shown in Figure 20. 18 L /A TX 1 RX D/C L /A TX TX 9 RX D/C TX Figure 20 Attaching a Fiber Optic Cable When you attach a fiber optic cable, be sure to observe the following guidelines: ❑ Be sure that the cable connector is firmly locked into place in the port. ❑ A dual SC port consists of two separate connectors, as shown in Figure 21. Each connects to a separate fiber strand.
AT-8500 Series Fast Ethernet Switch Installation Guide 4. ❑ You should verify that you are using the appropriate type of fiber optic cabling. For an AT-8516F/xx Series switch, refer to Planning the Installation on page 48. For an optional GBIC module, refer to the GBIC Installation Guide. For an optional fiber optic expansion module, refer to the Expansion Module Installation Guide.
Installation 5. Apply AC power to the switch by plugging the power cord into the AC power connector on the back panel of the unit (see Figure 22) and plugging the other end into a wall outlet. Warning The power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord. 10 Figure 22 Connecting the AC Power Cord When power is applied, the switch begins to load the AT-S62 software. The loading process takes approximately 20 to 30 seconds to complete.
AT-8500 Series Fast Ethernet Switch Installation Guide 6. If you installed an optional AT-RPS3004 Redundant Power Supply, connect one end of the DC power cord included with the RPS unit to the back panel of the AT-RPS3004 device and the other end to the RPS connector on the back panel of the switch, as shown in Figure 23. Figure 23 Connecting the RPS DC Cable Note The AT-RPS3004 unit is compatible with all AT-8500 Series switches, except for the AT-8524POE switch.
Installation Wiring a DC Powered Unit For a DC powered switch, perform the following steps: 1. Before you attach wires to the DC terminal block at the rear of the switch, review the following warning: Warning It is suggested that as a safety precaution, a 10 Amp circuit breaker should be installed at the supply end of the cable to be used with this LAN equipment. ALWAYS connect the wiring to the LAN equipment before connecting the wiring to the breaker.
AT-8500 Series Fast Ethernet Switch Installation Guide Warning Do not strip more than the recommended amount of wire. (See Figure 25.) Stripping more than the recommended amount can create a safety hazard by leaving exposed wire on the terminal block after installation. 17 8mm ±1mm (0.31in. ±0.039 in.) Figure 25 Stripped Wire 4.
Installation 7. Secure the tray supply cable near the rack framework using multiple cable ties to minimize the chance of the connections being disturbed by casual contact with the wiring. Use at least four cable ties separated four inches apart with the first one located within six inches of the terminal block. Note This system works with a positive grounded or negative grounded DC system. 20 8. Ensure that the circuit breaker is in the Off position. 9. Connect the DC wires to the circuit breaker.
AT-8500 Series Fast Ethernet Switch Installation Guide Starting a Local Management Session The procedure in this section explains how to start a local (out-of-band) management session using the RS-232 terminal port on the switch. You can use a local management session to configure the switch’s operating parameters and view performance and error statistics.
Installation 3. Set the terminal or the terminal emulation program to the following settings: ❑ Baud rate: 9600 bps ❑ Data bits: 8 ❑ Parity: None ❑ Stop bits: 1 ❑ Flow control: None Note The port settings are for a DEC VT100 or ANSI terminal, or an equivalent terminal emulator program. Note When you reset or power cycle the switch during a local management session, you will see the following prompt: Press B to go to Boot Prompt. This message is intended for manufacturing purposes only.
AT-8500 Series Fast Ethernet Switch Installation Guide Warranty Registration When you have finished installing the switch, fill out the enclosed warranty card and mail it to Allied Telesyn.
Chapter 3 Troubleshooting This chapter contains information on how to troubleshoot the switch in the event that a problem occurs. Note If after following the instructions in this chapter you are unable to resolve the problem, contact Allied Telesyn Technical Support for assistance. Refer to Contacting Allied Telesyn on page 10 for contact information. Check the PWR LED on the front of the switch.
AT-8500 Series Fast Ethernet Switch Installation Guide For twisted pair ports, verify that the LINK LED for each port is ON. If a Link LED is OFF, do the following: Verify that the end node connected to the port is powered ON and is operating properly. Check that the twisted pair cable is securely connected to the port on the switch and to the port on the end node. Make sure that the twisted pair cable does not exceed 100 m (328 ft).
Troubleshooting Make sure that you are using the appropriate type of fiber optic cable and that the cable length does not exceed the allowed maximum distance. For an AT-8516F Series switch, refer to Planning the Installation on page 48. For an optional GBIC or SPF module, or other expansion module, refer to the Installation Guide shipped with the module. Use a fiber optic tester to test the attenuation on the cable to determine if the strength of the fiber optic signal falls below acceptable limits.
AT-8500 Series Fast Ethernet Switch Installation Guide Verify that the twisted pair cable is Category 5 or 5E. Verify that the twisted pair cable is not faulty. Use the AT-S62 management software to determine whether PoE is enabled on the switch and the port. The default setting for PoE is enabled. Use the management software to determine whether the PoE power setting for the port has been reduced from the default setting of 15.4 W, to a value below the power requirements of the device.
Troubleshooting Check to be sure that the operating parameters on the terminal or the terminal emulation program, if you are using a personal computer, have been set correctly. The default settings for the RS-232 terminal port can be found in Starting a Local Management Session on page 69.
Appendix A Technical Specifications Physical Specifications AT-8516F/SC and AT-8524M Dimensions 4.4 cm x 44.0 cm x 22.2 cm (1.75 in. x 17.3 in. x 8.75 in.) (H x W x D) AT-8550GB and AT-8550SP Dimensions 4.4 cm x 44.0 cm x 25.5 cm (1.75 in. x 17.3 in. x 10.0 in.) (H x W x D) AT-8524POE Dimensions: 4.4 cm x 43.8 cm x 40.6 cm (1.75 in. x 17.25 in. x 16.0 in.) (H x W x D) Weight: AT-8516F/SC AT-8524M AT-8524POE AT-8550GB AT-8550SP Recommended Minimum Ventilation on All Sides: 3.4 kg (7.4 lb.) 3.
Technical Specifications Environmental Specifications Operating Temperature: 0° C to 40° C (32° F to 104° F) Storage Temperature: -25° C to 70° C (-13° F to 158° F) Operating Humidity: 5% to 90% non-condensing Storage Humidity: 5% to 95% non-condensing Maximum Operating Altitude: 4,000 m (13,000 ft) Maximum Non-operating Altitude: 4,000 m (13,000 ft) 78
AT-8500 Series Fast Ethernet Switch Installation Guide Power Specifications Input Voltage: All models excluding AT-8524POE: AC DC 100-240 VAC, 2A maximum, 50/60 Hz 36-60 VDC, 4A maximum AT-8524POE: AC 100-240 VAC, 6A maximum, 50/60 Hz Maximum Power Consumption: All models excluding AT-8524POE: 74 watts AT-8524POE: 497 watts 79
Technical Specifications Safety and Electromagnetic Emissions Certifications EMI: FCC Class A, EN55022 Class A, VCCI Class A, C-TICK, EN61000-3-2, EN61000-3-3 Immunity: EN55024 Safety: UL 60950 (UL/cUL), EN60950 (TUV) Quality and Reliability: MTBF > 90,000 hrs, MTTR < 1/2 hr 80
AT-8500 Series Fast Ethernet Switch Installation Guide Standards IEEE 802.3 (10Base-T Ethernet) IEEE 802.3u (100Base-TX Ethernet) IEEE 802.Q (Virtual LAN tagging) IEEE 802.3x (Flow Control) IEEE 802.3ad (Link Aggregation) IEEE 802.1x (Port Based Network Access Control) IEEE 802.1Q (Port-based and tagged VLANs) IEEE 802.1p (Class of Service) IEEE 802.1d (Spanning Tree Protocol) IEEE 802.1w (Rapid Spanning Tree Protocol) IEEE 802.1s (Multiple Spanning Tree Protocol) RFC 1112 (IGMP Snooping Version 1.
Technical Specifications SNMP Support RFC 1213 (MIB II) RFC 1215 (TRAP MIB) RFC 1493 (Bridge MIB) RFC 1643 (Ethernet MIB) RFC 2863 (Interface Group MIB) Allied Telesyn MIBs for the AT-8500 Series switch (atistackswitch.mib and atistackinfo.
AT-8500 Series Fast Ethernet Switch Installation Guide RJ-45 Twisted Pair Port Pinouts Figure 28 illustrates the pin layout of an RJ-45 port. Pin 1 Figure 28 RJ-45 Port Pin Layout Table 10 lists the RJ-45 pin signals for the 10/100Base-TX ports on the AT-8524M, AT-8550GB, and AT-8550SP switches.
Technical Specifications Table 11 lists the RJ-45 port pin signals on the 10/100Base-TX ports on an AT-8524POE switch. Table 11 10/100Base-T Port MDI/MDI-X Pin Signals with PoE Pin MDI Signal MDI-X Signal 1 TX+ and Vport-11 RX+ and Vport-1 2 TX- and Vport-1 RX- and Vport-1 3 RX+ and Vport-22 TX+ and Vport-2 4 Unused Unused 5 Unused Unused 6 RX- and Vport-2 TX- and Vport-2 7 Unused Unused 8 Unused Unused 1.
AT-8500 Series Fast Ethernet Switch Installation Guide Table 12 lists the RJ-45 pin signals for the two 10/100/1000-Base-T ports on the AT-8550GB switch when the ports are operating at 1000 Mbps.
Technical Specifications AT-8516F/SC Fiber Optic Port Specifications Standard: 100Base-FX Speed: 100 Mbps Maximum Operating Distance: 2 km (1.24 mi) Connectors: AT-8516F/SC Dual SC Connector Type of Cabling: 50/125 micron or 62.5/125 micron (core/cladding) multimode fiber optic cabling Operating Wavelength: 1310 nm Transmitter Output Power: 50/125 micron cabling Minimum: Maximum: -22.5 dBm average -14 dBm average 62.
AT-8500 Series Fast Ethernet Switch Installation Guide RS-232 Terminal Port Pinouts Table 13 lists the pin signals on the RS-232 terminal port.
Technical Specifications RPS Connector Port Pinouts Figure 29 illustrates the pin layout to the 16-pin molex connector and RPS port on the AT-8516F/SC, AT-8524M, AT-8550GB, and AT-8550SP switches. 9 1 16 9 1 16 8 8 Figure 29 RPS 16-pin Molex Connector Pin Layout Table 14 lists the 16-pin RPS connector pins and definitions. Table 14 Pin Definitions of the 16-pin RPS Connector Pin Definition 1 +5V DC 2 Remote Sense (RS) +3.3 V DC 3 RS -3.3 V DC 4 RS +2.
AT-8500 Series Fast Ethernet Switch Installation Guide Table 14 Pin Definitions of the 16-pin RPS Connector (Continued) Pin Definition 16 +3.3V DC Return Figure 30 illustrates the pin layout to the RPS connector on the AT-8524POE switch. A2 7 15 1 A1 8 Figure 30 AT-8524POE RPS Connector Pin Layout Table 15 lists the RPS connector pins and definitions.
Technical Specifications Table 15 Pin Definitions for the RPS Connector on the AT-8524POE Switch Pin Definition 12 3.3V RS- 13 3.3V RS+ 14 3.3V 15 3.
AT-8500 Series Fast Ethernet Switch Installation Guide Dual SC Type Connector This connector is used with the AT-8516F/SC switch. Figure 31 illustrates a dual SC connector.
Appendix B Translated Electrical Safety and Emission Information Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
AT-8500 Series Fast Ethernet Switch Installation Guide Standards: This product meets the following safety standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Translated Electrical Safety and Emission Information 12 PLUGGABLE EQUIPMENT, the socket outlet shall be installed near the equipment and shall be easily accessible. 13 CAUTION: Air vents must not be blocked and must have free access to the room ambient air for cooling. 14 OPERATING TEMPERATURE: This product is designed for a maximum ambient temperature of 40° degrees C. 15 ALL COUNTRIES: Install product in accordance with local and National Electrical Codes.
AT-8500 Series Fast Ethernet Switch Installation Guide Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. 1 Hochfrequenzstörung 2 WARNUNG: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen.
Translated Electrical Safety and Emission Information 17 WARNUNG: Ziehen Sie nicht mehr als die empfohlene Drahtlänge ab. Wird mehr als die empfohlene Länge abisoliert, stellt dies ein Sicherheitsrisiko dar, da auf dem Anschlußklemmblock nach der Installation möglicherweise freiliegende Drähte verbleiben. 18 WARNUNG: Bei der Installation dieser Einrichtung ist stets sicherzustellen, daß der Masseanschluß jeweils zuerst installiert und zuletzt getrennt wird.
AT-8500 Series Fast Ethernet Switch Installation Guide Standarder: Dette produkt tilfredsstiller de følgende standarder. 1 Radiofrekvens forstyrrelsesemission 2 ADVARSEL: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger.
Translated Electrical Safety and Emission Information 17 ADVARSEL: Man bør ikke afisolere mere af ledningerne end anvist, for så kan sådanne blanke ledninger udgøre et faremoment efter montering på klemmerækken. 18 ADVARSEL: Ved installering af dette udstyr skal steljord altid forbindes først og aftages sidst. 19 FORSIKTIG: “Fare” Se omhyggeligt efter om der stikker blanke kobbertråde ud fra klemmeforbindelserne. Ved korrekt montering er det ikke tilfældet.
AT-8500 Series Fast Ethernet Switch Installation Guide Eisen: Dit product voldoet aan de volgende eisen. 1 RFI Emissie 2 WAARSCHUWING: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen.
Translated Electrical Safety and Emission Information 17 WAARSCHUWING: Verwijder niet meer dan de aanbevolen hoeveelheid isolatiemateriaal. Als u meer dan de aanbevolen hoeveelheid verwijdert, kan dit een veiligheidsrisico veroorzaken doordat draden bloot blijven liggen na aansluiting op het blok. 18 WAARSCHUWING: Zorg er tijdens installatie van de apparatuur altijd voor dat de aardeaansluiting van het frame als eerste wordt geplaatst en als laatste wordt losgemaakt.
AT-8500 Series Fast Ethernet Switch Installation Guide Normes: ce produit est conforme aux normes de suivantes: 1 Emission d’interférences radioélectriques 2 MISE EN GARDE : dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates.
Translated Electrical Safety and Emission Information 17 AVERTISSEMENT: Ne coupez pas une quantité de câble supérieure à celle qui est recommandée. Cela pourrait constituer un risque de sécurité en laissant du câblage à nu sur le bornier après l’installation. 18 AVERTISSEMENT: Lors de l’installation de cet équipement, vérifiez toujours que la connexion de terre du châssis est installée en premier et débranchée en dernier.
AT-8500 Series Fast Ethernet Switch Installation Guide Standardit: Tämä tuote on seuraavien standardien mukainen. 1 Radioaaltojen häirintä 2 VAROITUS: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin.
Translated Electrical Safety and Emission Information 17 VAROITUS:Älä poista johtimesta päällystettä enempää kuin on suositeltu. Päällysteen poistaminen suositusta pidemmältä matkalta voi aiheuttaa turvallisuusriskin, sillä riviliittimeen jää asennuksen jälkeen paljaita johtimia. 18 VAROITUS:Kun asennat tätä laitetta, varmista aina, että runkomaadoitettu liitin kytketään ensin ja irrotetaan viimeiseksi.
AT-8500 Series Fast Ethernet Switch Installation Guide Standard: Questo prodotto è conforme ai seguenti standard. 1 Emissione RFI (interferenza di radiofrequenza) 2 AVVERTENZA: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati provvedimenti.
Translated Electrical Safety and Emission Information Collegare SEMPRE il cablaggio prima all’apparecchiatura LAN e poi all’interruttore. Per evitare i infortuni causati da folgorazione, non lavorare su cavi SOTTO TENSIONE. Prima di collegare il cavo all’interruttore di sicurezza, accertarsi sempre che quest’ultimo sia disinserito.
AT-8500 Series Fast Ethernet Switch Installation Guide Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. 1 RFI stråling 2 ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler.
Translated Electrical Safety and Emission Information 17 ADVARSEL: Du skal ikke avisolere mer av ledningen enn det som er anbefalt. Dersom du avisolerer mer enn det som er anbefalt, kan dette forårsake en sikkerhetsfare, ettersom det vil finnes uisolert ledning på rekkeklemmen etter montering. 18 ADVARSEL: Når du monterer dette utstyret, skal du alltid passe på at forbindelsen til rammejordingen monteres først og koples fra sist.
AT-8500 Series Fast Ethernet Switch Installation Guide Padrões: Este produto atende aos seguintes padrões. 1 Emissão de interferência de radiofrequência 2 AVISO: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas.
Translated Electrical Safety and Emission Information 17 AVISO: Não corte mais fio do que recomendado. Cortar mais do que o recomendado pode ser perigoso, por deixar fio exposto no terminal depois da instalação. 18 AVISO: Ao ligar este equipamento, instale sempre primeiro a ligação à terra e desligue-a sempre em último. 19 ATENÇÃO: “Perigo” Verifique se há algum fio de cobre exposto a sair do fio instalado.
AT-8500 Series Fast Ethernet Switch Installation Guide Estándares: Este producto cumple con los siguientes estándares. 1 Emisión RFI 2 ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto.
Translated Electrical Safety and Emission Information SIEMPRE conecte los cables al equipo LAN primero, antes de conectarlos al cortacircuitos. Para evitar el peligro de sufrir daños corporales a causa de sacudidas eléctricas, no trabaje con conductores CON CORRIENTE. Asegúrese siempre de que el cortacircuitos esté en la posición de APAGADO (OFF) antes de conectar los cables al cortacircuitos.
AT-8500 Series Fast Ethernet Switch Installation Guide Standarder: Denna produkt uppfyller följande standarder. 1 Radiostörning 2 VARNING: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder. 3 Immunitet EN55024 4 Elsäkerhet UL 60950 (UL/cUL), EN60950 (TUV) 5 Laser EN60825 FCC Klass A, EN55022 Klass A, VCCI Class A, C-TICK, EN61000-3-2, EN61000-3-3 SÄKERHET 6 VARNING! Laserprodukt av klass 1.
Translated Electrical Safety and Emission Information 17 VARNING: Skala inte av mer isolering än vad som anges ovan. Skalas för mycket isolering av kan fara uppstå om oskyddad tråd vidröras på anslutningsplinten efter anslutningen. 18 VARNING: Vid anslutning av denna utrustning skall man alltid se till att jordtråden ansluts först och lossas sist. 19 OBS! FARA! Kontrollera om små koppartrådar sticker ut ifrån den anslutna tråden.