Installation guide
The following table lists the line card status and basic alarms LED’s
provisioned on the Base Board and are viewable through the left side of the
line card front panel.
DIP Switches
The AT-CM70S line card features only the Diagnostic Mode DIP Switch,
which is located on the base board.
The table below lists the positions of the DIP switch.
LED Color Description
RDY Green The line card has passed diagnostics.
OFF The line card has not passed diagnostics.
L/A Green The TX port has established a valid link.
Blinking
Green
The TX port has detected TX/RX activity.
FD Green The TX port is operating in full-duplex mode.
OFF The TX port is operating in half-duplex mode
(intermittently ON when there is collision).
100 Green The TX port is operating at 100 Mbps speed.
OFF The TX port is operating at 10 Mbps speed.
LK Green The SFP port establishes a valid link.
OFF The SFP port has no link.
CONSOLE
(applies to
AT-CV5000
chassis only)
Green The line card is managed from its local console.
OFF The line card is managed from the CPM
module located in the rear of the chassis.
OAM Green The OAM mode is enabled (visible or bypass)
and can be set by the DIP switches.
OFF The OAM mode is disabled.
Operating Mode DIP 1 DIP 2
Link Test (non-OAM) OFF X
OAM Bypass ON OFF
OAM Visible ON ON
Manufacturing Default Settings OFF OFF
“X” means the DIP switch position could be either ON or OFF.
Installing an AT-CM70S Line Card
Note
The Converteon™ line cards can be installed in any of the line card slots
located on the front panel of the Converteon™ chassis.
To install an AT-CM70S line card, perform the following procedure:
Caution
Before installing an AT-CM70S line card, refer to the appropriate
Converteon™ Series Chassis Installation Guide and/or the
Converteon™ Media Converter Line Cards Reference Guide the for
electrical safety and emission information.
Caution
Be sure to observe all standard electrostatic discharge (ESD)
precautions, such as wearing an antistatic wrist strap, to avoid
damaging the device. A line card can be damaged by static electricity.
1. Remove the Converteon™ line card from its shipping package and store
the package in a safe place.
2. You must use the original package if you need to return the unit to Allied
Telesis.
3. Select two empty line card slots adjacent to each other in the AT-CV5000
chassis for the card.
4. Remove the AT-CV5PNL1 blank slot covers from the selected slots.
Keep the blank slot covers in a safe area in case you remove the line
card. The blank slot covers are used to keep dust from getting into the
chassis and maintain proper airflow, cooling, and ventilation throughout
the chassis.
5. Locate the alignment guides in the chassis slot.
6. Align the back edge of the line card with the alignment guides located
inside the slot. Avoid touching the line card components.
–- For the AT-CV5000, align with the top and bottom alignment guides.
–- For the AT-CV1200, align with the left and right alignment guides.
7. Slide the line card until the front of the card is flushed with the front of the
chassis.
8. Use a Phillips screwdriver to tighten the captive screws on the line card.
Note
Always tighten the captive screws to secure the line card to the chassis.
This help ensure that the connectors at the back of the line card are
securely connected to the backplane.
Caution
When used in the AT-CV1200 chassis, make sure the ground lug is
attached prior to operating the AT-CM70S line card. For grounding
instruction, refer to the AT-CV1200 Chassis Installation Guide.
Removing an AT-CM70S Line Card
To remove an AT-CM70S line card, refer to the Converteon™ Media
Converter Line Cards Reference Guide for instructions.
Technical Specifications
Physical, Environmental, and Electrical Rating
Dimensions (H x W x L) 1.71" x 2.89" x 5.1"
(4.4 cm x 7.3 cm x 13.0 cm)
Operating Temperature 0° C to 40° C (32° F to 104° F)
Storage Temperature -25° C to 70° C (-13° F to 158° F)
Operating Relative Humidity 5% to 90% RH (non-condensing)
Storage Relative Humidity 5% to 95% RH (non-condensing)
Operating Altitude Range Up to 3,048 m (10,000 ft)
MTBF (Telcordia Standards) 670,000 hrs
Power Consumption 8.5 watts
Pluggable Slot Type SFP
Electrical Safety and Emission Statement
Standards: This product meets the following standards when installed in compliant host equipment.
Emission FCC Class A, EN55022 Class A, VCCI Class A, C-TICK, CE
WARNING: In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
Immunity EN55024
Electrical Safety UL60950-1 (
c
UL
us
), EN60950-1 (TUV), CAN/CSA C22.2 No. 60950-1
Telecommunications: FCC Part 68 (TIA/EIA/IS-968); Industry Canada CS-03
ACTA Product ID
– US: A5TDWNANAT-CM70S
Industry Canada Registration
– IC: 3336-ATCM70S
Copyright 2006 Allied Telesis, Inc. All rights reserved.
No part of this publication may be reproduced without prior written permission from Allied Telesis Inc.
U.S. Federal Communications Commission
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant
to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with this instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct the interference at
his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right
to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur
du Canada.
4 5 6