CONVERTEON™ Family Two-Slot Chassis AT-CV1203 Installation Guide 613-001163 Rev.
Copyright © 2009 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Allied Telesis is a trademark of Allied Telesis, Inc. Microsoft and Internet Explorer are registered trademarks of Microsoft Corporation. Netscape Navigator is a registered trademark of Netscape Communications Corporation.
Electrical Safety and Emissions Standards This product meets the following standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Translated Safety Statements Important: The indicates that a translation of the safety statement is available in a PDF document titled Translated Safety Statements posted on the Allied Telesis website at www.alliedtelesis.com and on the documentation CD shipped with this product.
Contents Preface ................................................................................................................................................................................11 Safety Symbols Used in this Document................................................................................................................................12 Where to Find Web-based Guides .....................................................................................................................
Contents 6
Figures Figure 1. AT-CV1203 Chassis .............................................................................................................................................16 Figure 2. Front and Back Panels of the AT-CV1203 Chassis..............................................................................................17 Figure 3. AT-CVMNT12 Wall-Mount Bracket.......................................................................................................................18 Figure 4.
Figures 8
Tables Table 1. Safety Symbols .....................................................................................................................................................12 Table 2. Power LEDs ..........................................................................................................................................................19 Table 3. AT-CV1203 Chassis Components .................................................................................................................
Tables 10
Preface This guide contains the installation instructions for the Converteon AT-CV1203 Chassis.
Preface Safety Symbols Used in this Document This document uses the safety symbols defined in Table 1. Table 1. Safety Symbols Symbol 12 Meaning Description Caution Performing or omitting a specific action may result in equipment damage or loss of data. Warning Performing or omitting a specific action may result in electrical shock.
AT-CV1203 Chassis Installation Guide Where to Find Web-based Guides The installation and user guides for all Allied Telesis products are available in portable document format (PDF) on our web site at www.alliedtelesis.com. You can view the documents online or download them onto a local workstation or server.
Preface Contacting Allied Telesis This section provides Allied Telesis contact information for technical support as well as sales and corporate information. Online Support You can request technical support online by accessing the Allied Telesis Knowledge Base: www.alliedtelesis.com/support/kb.aspx. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
Chapter 1 Overview This chapter contains the following sections: “Features” on page 16 “Front and Back Panels” on page 17 “AT-CVMNT12 Wall-Mount Bracket” on page 18 “LEDs” on page 19 “Operations, Administration and Maintenance Features” on page 20 15
Chapter 1: Overview Features The AT-CV1203 Chassis is part of the Converteon product line. It is a twoslot enclosure for the Fast and Gigabit Ethernet media converter line cards and the AT-CV5M02 Management Card. The chassis is compatible with all the Converteon line cards and can accommodate two line cards, one line card and the AT-CV5M02 Management Card, or the dual-slot AT-CM70S Media Converter Line Card.
AT-CV1203 Chassis Installation Guide Front and Back Panels Figure 2 shows the front and back panels of the AT-CV1203 Chassis. Slot 2 Allied Telesis AT-CV1203 22 CLASS 1 LASER PRODUCT 11 1578 Slot 1 DC Power Connectors (PWR A and PWR B) PWR Good LED PWR GOOD Tie Wrap Anchors PWR A PWR B 12VDC 12VDC 1579 Grounding Lug Screws Power Adapter LEDs Figure 2.
Chapter 1: Overview AT-CVMNT12 Wall-Mount Bracket The AT-CV1203 Chassis can be mounted on a wall with the optional AT-CVMNT12 Wall-Mount Bracket, shown in Figure 3. To order the bracket, contact your Allied Telesis sales representative. 1015 Figure 3.
AT-CV1203 Chassis Installation Guide LEDs Figure 4 identifies the power LEDs on the rear panel. PWR Good LED Power Adapter LEDs PWR A PWR GOOD PWR B 12VDC 12VDC 1579 Figure 4. Power LEDs Table 1 describes the power LEDs. Table 1. Power LEDs LED PWR GOOD PWR A PWR B State Description Green The power being supplied to the line cards is within the normal operating range. OFF The chassis is not receiving power or the power is outside the normal operating range.
Chapter 1: Overview Operations, Administration and Maintenance Features The AT-CV1203 Chassis supports all the Operations, Administration and Maintenance (OAM) features of the managed AT-CM2 Series and AT-CM3 Series Line Cards and the AT-CM70S Line Card.
Chapter 2 Installation This chapter contains the following installation procedures for the AT-CV1203 Chassis: “Reviewing the Safety Precautions” on page 22 “Selecting a Site for the Chassis” on page 23 “Unpacking the Chassis” on page 24 “Installing the Rubber Feet” on page 26 “Installing a Converteon Line Card” on page 27 “Grounding the Chassis” on page 30 “Powering On the Chassis” on page 32 “Verifying the Installation” on page 35 “Replacing a Line Card or the Managemen
Chapter 2: Installation Reviewing the Safety Precautions Please review the following safety precautions before you begin to install the chassis or any of its components. Note The indicates that a translation of the safety statement is available in a PDF document titled Translated Safety Statements on the Allied Telesis website at www.alliedtelesis.com and on the documentation CD shipped with this product. Warning: Do not work on equipment or cables during periods of lightning activity.
AT-CV1203 Chassis Installation Guide Selecting a Site for the Chassis The site chosen for the unit should meet the following requirements: The power outlet should be close to the chassis and be easily accessible. The site should allow for easy access to the media converter module slots on the front panel and to the power supply connectors on the back panel. There should be unrestricted air flow around the vents of the chassis. There should not be any objects placed on top of the chassis.
Chapter 2: Installation Unpacking the Chassis As you unpack the unit, verify that all the items listed in Table 2 are included in the shipping container. If an item is missing or damaged, contact your Allied Telesis sales representative for assistance. Note Store the packaging material in a safe location. You must use the original shipping material if you need to return the unit to Allied Telesis. Table 2.
AT-CV1203 Chassis Installation Guide Table 2.
Chapter 2: Installation Installing the Rubber Feet If you are installing the AT-CV1203 Chassis on a desktop, turn the unit over and attach the four rubber feet to the corners, as shown in Figure 5. 1 1572 LA CLA SER S PRS 1 OD UC T 2 AT-C lesis V12 03 d Te Allie Figure 5.
AT-CV1203 Chassis Installation Guide Installing a Converteon Line Card To install a Converteon media converter line card or the AT-CV5M02 Management Card in the chassis, perform the following procedure: 1. Using a Phillips-head screwdriver, loosen the captive screw on one of the AT-CV5PNL1 blank slot covers and remove the cover. The cards can be installed in either slot. If you are installing the AT-CM70S Line Card, remove the covers from both slots.
Chapter 2: Installation Note Empty slots should be kept covered. Retain the slot cover and reinstall it if you ever remove the line card without replacing it. 2. Remove the Converteon media converter line card or the AT-CV5M02 Management Card from its shipping package. Store the package in a safe place. You must use the original package if you need to return the unit to Allied Telesis.
AT-CV1203 Chassis Installation Guide All ied AT-CV5PNL1 AT Tele -C sis V1 20 3 SML ML OAM 100M RDY X T LK AT FD S F P AT-CM302 LK AT LA CL SE AS RP S1 RO DU CT 1575 Figure 8. Inserting a Line Card 6. Use a Phillips screwdriver to tighten the captive screw on the line card, as shown in Figure 9. All ied RDY SML ML OAM 100M LK AT FD X T S F P AT-CM302 LK AT LA CL SE AS RP S1 RO DU CT AT-CV5PNL1 AT Tele -C sis V1 20 3 1576 Figure 9. Tightening the Captive Screw 7.
Chapter 2: Installation Grounding the Chassis This procedure requires these items: Phillips head No. 2 screwdriver 10 AWG solid wire (The length of the wire will depend on your installation.) Crimping tool Grounding lug (included with the chassis) To ground the AT-CV1203 Chassis, perform the following procedure: 1. Strip the grounding wire as shown in Figure 10. 11mm ±1mm (0.44in. ±0.03in.) 100 Figure 10. Stripping the Grounding Wire 2.
AT-CV1203 Chassis Installation Guide 3. Remove the two grounding lug screws from the back panel of the chassis. PW RG OO D PW RA 12 VD C PW RB 12 VD C 1580 Figure 12. Removing the Grounding Lug Screws 4. Attach the grounding lug to the back panel of the chassis using the two screws removed in the previous step. PW RG OO D PW RA 12 VD C PW RB 12 VD C 1581 Figure 13. Attaching the Grounding Lug 5.
Chapter 2: Installation Powering On the Chassis Note Use only power sources that are UL Listed (QQGQ or EPBU), TUV Licensed or other Safety Agencies approved, and that are suitable for country of use. To power on the AT-CV1203 Chassis, perform the following procedure: 1. Connect the power cord to the power adapter, as shown in Figure 14. 1577 Figure 14. Connecting the Power Adapter and Power Cord 2.
AT-CV1203 Chassis Installation Guide PW RG OO D PW PW RA RB 12 VD C 12 VD C 1582 Figure 15. Connecting the Power Cord 3. To prevent accidentally disconnecting the power cord from the chassis, secure the cord to the tie anchor with a tie wrap. PW RG OO D PW PW RA RB 12 VD 12 C VD C 1582 Figure 16.
Chapter 2: Installation 4. Connect the power cord to an appropriate power source. For the power requirements, refer to “Power Specifications” on page 37. The chassis is now ready for network operations. Warning: Power cord is used as a disconnection device. To deenergize equipment, disconnect the power cord. E3 Pluggable Equipment. The socket outlet shall be installed near the equipment and shall be easily accessible. E5 5. If you purchased a second power adapter, repeat this procedure to install it.
AT-CV1203 Chassis Installation Guide Verifying the Installation After powering on the chassis, view the PWR GOOD LED. The LED should be ON. The PWR A and PWR B LEDs should also be ON for DC connectors that are connected to power adapters. If an LED is OFF, perform the following: Verify that the power cord is firmly connected to the AC power source and to the power adapter. Verify that the power adapter is firmly connected to a DC connector on the back panel of the chassis.
Chapter 2: Installation Replacing a Line Card or the Management Card All the Converteon media converter line cards and the AT-CV5M02 Management Card support hot-swapping and can be installed while the chassis is powered on. To replace a line card, perform the following procedure: 1. Disconnect all the cables from the line card you want to remove from the chassis. 2. Insert the dust cap into the fiber optic port on the line card. 3.
Appendix A Technical Specifications Physical Specifications Dimensions: 5.40 cm x 13.12 cm x 15.52 cm (2.12 in x 5.17 in x 6.11 in) (H x W x L): Weight: 0.9 kg (1.98 lb) Environmental Specifications Operating Temperature: 0° C to 40° C (32° F to 104° F) Storage Temperature: -25° C to 70° C (-13°F to 158° F) Operating Humidity: 5% to 90% non-condensing Storage Humidity: 5% to 95% non-condensing Maximum Operating Altitude: 3,000 m (10,000 ft.) Maximum Storage Altitude: 4,000 m (13,100 ft.
Appendix A: Technical Specifications Safety and Electromagnetic Emissions Certifications 38 EMI: FCC Class A, EN55022 Class A, VCCI Class A, C-TICK, CE Immunity: EN55024 Safety: UL60950-1 (CULUS), EN60950-1 (TUV), CAN/CSA C22.2 No. 60950-1 Laser: EN60825 Quality and Reliability: MTBF > 310,000 hrs.