Installation guide

16
7. Attach the data cables to the AT-FH705E
ports. Do not use a cross-over cable to connect
workstations or servers to ports 1 through 5.
Do not use a cross-over cable to connect
another AT-FH705E to the Uplink port.
Note
You can use either port 5 or the Uplink
port, but you cannot use both
simultaneously.
8. Go to the procedure “Verifying and
Troubleshooting the Installationon page 16.
Verifying and Troubleshooting the
Installation
The following procedure should be perform
after you have initially installed the unit to
check to be sure that the device is operating
properly. You can also perform this procedure
to troubleshoot the unit in the event you
experience any problems with the device.
1. Check the Power LED. The LED should be
ON. If the Power LED is OFF, check the
following:
Check to be sure that the power adapter is
securely connected to the power source
and to the DC connector on the front of the