AT-FS211 AT-FS212 AT-FS212/1 AT-FS212/2 AT-FS212/3 AT-FS212/4 AT-FS214 AT-FS215 AT-FS216 AT-FS217 Wall-Mountable Fast Ethernet Switches Installation Guide PN 613-50226-00 Rev B
Copyright 2001 Allied Telesyn International Corp. 960 Stewart Drive, Suite B, Sunnyvale CA 94085 USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn International Corp.
Safety Warnings Standards: This product meets the following standards. U.S. Federal Communications Commission DECLARATION OF CONFORMITY Manufacture Name: Allied Telesyn International Corp.
Safety Warnings Warning: This product requires shielded cables to comply with emission and immunity standards. If it is used with unshielded cables, the user may be required to take measures to correct the interference problem at their own expense. $ 4 Electrical Safety EN60950 (TUV), UL1950 (UL/cUL)$ 5 Laser EN60825 $ 6 Warning Class 1 Laser product. (AT-FS212/x models) $ 7 Warning Do not stare into the Laser beam.
Table of Contents Safety Warnings ............................................................................................iii Welcome to Allied Telesyn ......................................................................... vii Where to Find Web-based Guides ................................................................... vii Document Conventions .................................................................................... vii Contacting Allied Telesyn ......................................
Chapter 3 Troubleshooting ........................................................................................... 15 Appendix A Technical Specifications ............................................................................ 17 Specifications .................................................................................................... 17 Physical ...................................................................................................... 17 Temperature .............................
Welcome to Allied Telesyn This installation guide contains instructions on how to wall-mount the AT-FS21x and the AT-FS212/x Series Fast Ethernet Switches and how to connect the units to your network. Where to Find Web-based Guides The Allied Telesyn web site at www.alliedtelesyn.com provides you with an easy way to access the most recent documentation, software, and technical information for all of our products. For product guides, you can go directly to the following web page: www.alliedtelesyn.
Welcome to Allied Telesyn Contacting Allied Telesyn You can contact Allied Teleysn technical support online or by telephone, fax, or e-mail. Online Support You can request technical support online by filling out the Online Technical Support Form at www.alliedtelesyn.com/support/supportf.asp or by accessing the Technical Support Knowledge Base from Allied Telesyn’s North American web site.
AT-FS21x and AT-FS212/x Series Installation Guide Technical Support E-mail Addresses United States and Canada TS1@alliedtelesyn.com Latin America, Mexico, Puerto Rico, Caribbean, and Virgin Islands latin_america@alliedtelesyn.com Europe support_europe@alliedtelesyn.com Returning Products Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense.
Welcome to Allied Telesyn For Sales or Corporate Information You can contact Allied Telesyn for sales or corporate information at one of the locations below: Allied Telesyn International Corp. 19800 North Creek Parkway, Suite 200 Bothell, WA 98011 Tel: 1 (425) 487-8880 Fax: 1 (425) 489-9191 Allied Telesyn International Corp.
Chapter 1 Overview The AT-FS21x and AT-FS212/x Series Fast Ethernet Switches feature the following models: ❑ AT-FS211 ❑ AT-FS212/4 ❑ AT-FS212 ❑ AT-FS214 ❑ AT-FS212/1 ❑ AT-FS215 ❑ AT-FS212/2 ❑ AT-FS216 ❑ AT-FS212/3 ❑ AT-FS217 These switches are designed to interconnect LAN devices and subnetworks over large distances. These dual-port switches can also improve the performance of your network by dividing it into smaller, more manageable segments.
Overview These switches are easy to install and do not require software configuration or management. Figure 1 illustrates an AT-FS21x Series Switch. Mounting Bracket Screws LEDs itch rnet Sw FS2he14 ATFast Et PWR FX TX 10Base-T/ X 100Base-T 3.3 VDC Cable Hook 10/100Base-TX Port DC Connector Figure 1 AT-FS21x Series Switch (Model AT-FS214) Table 1 lists the operating distances for the AT-FS21x and AT-FS212/x Series Switches. Table 1 Maximum Operating Distance 10/100Base-TX1 Model 1. 2.
AT-FS21x and AT-FS212/x Series Installation Guide Key Features The switches have the following key features: ❑ LEDs for unit and port status ❑ Wall-mountable chassis ❑ Auto MDI/MDI-X ❑ External AC/DC power adapters (North America, Continental, or Europe) ❑ Full- or half-duplex mode operation on the twisted pair port ❑ Full-duplex operation on the fiber optic port ❑ FJ, LC, MT-RJ, SC, ST, or VF-45 fiber optic connector ❑ Data packet forwarding and filtering at full wire speed ❑ Store and f
Overview Status LEDs Table 2 lists the switch LEDs. Table 2 AT-FS21x and AT-FS212/x Series Switch LEDs LED Color Description PWR Green Power is applied. FX Green A link has been established on the fiber optic port Blinking Activity has been detected on the fiber optic port. Green A link has been established on the twisted pair port Blinking Activity has been detected on the twisted pair port. Green The twisted pair port is operating at 100 Mbps.
AT-FS21x and AT-FS212/x Series Installation Guide Functional Description Frame Processing The switches support store and forward switching at Fast Ethernet full-wire speed in 10 or 100 Mbps, half- or full-duplex mode. Packets entering each port are stored in buffers. After the full packet is received, it is forwarded or discarded depending on its destination address and error status.
Overview Network Topologies Figure 2 illustrates a topology using one AT-FS214 switch to interconnect two small networks of stackable hubs. Network 1 has an AT-FH812u with an AT-FH807u switching module connected to the 100Base-FX port on the AT-FS214. Network 2 has an AT-3624TR hub connected to the 10/100Base-TX port on the AT-FS214.
Chapter 2 Installing the Switch Verifying the Package Contents Make sure the following items are included in your package. If any item is missing or damaged, contact your Allied Telesyn sales representative for assistance.
Installing the Switch Table 3 10/100Base-TX Twisted Pair Port Cabling Specifications Operating Mode Twisted Pair Cable Maximum Operating Distance 10Base-T Shielded or unshielded Category 3 or better 100 m (328 ft) 100Base-TX Shielded or unshielded Category 5 or better 100 m (328 ft)7 Table 4 100Base-FX Fiber Optic Port Cabling Specifications (Full-duplex) Maximum Operating Distance Maximum Allowable Loss Budget 50/125 or 62.5/125 micron multimode 2 km (1.
AT-FS21x and AT-FS212/x Series Installation Guide Note Refer to page 18 for additional fiber optic port specifications. Selecting a Site Be sure to observe the following requirements when choosing a site for your switch. ❑ Select a site that is dust-free and moisture-free. ❑ Be sure that the site will allow you to easily access the fiber optic and twisted pair cables and the power cord. ❑ Use dedicated power circuits or power conditioners to supply reliable power to the device.
Installing the Switch Caution Pluggable Equipment: The socket outlet should be installed near the equipment and should be easily accessible. $ 13 Caution Air vents: The air vents must not be blocked on the unit and must have free access to the room ambient air for cooling. $ 14 Caution Operating Temperature: This product is designed for a maximum ambient temperature of 40°C. $ 16 Caution All Countries: Install this product in accordance with local and National Electric Codes.
AT-FS21x and AT-FS212/x Series Installation Guide 3. Gently slide the bracket off the switch. See Figure 4. Figure 4 Sliding the Wall-mounting Bracket off the Switch Note For drywall installation, drill two 3/16-inch holes, insert the plastic anchors and tap flush. 4. Position the wall-mounting bracket on the wall and, using two Phillips-head screws (provided), secure the bracket to the wall. See Figure 5.
Installing the Switch Note The switch can be mounted either vertically or horizontally. 5. Using the flanges under the fiber optic port as a guide, slide the switch into the mounting bracket. Refer to Figure 6. Flange Flange AT-FS214 Fas t Ethernet Switch FX PWR TX LK/AT 100M Figure 6 Sliding the Switch Over the Wall-mounting Bracket 6. Secure the switch to the wall-mounting bracket using the screws removed in Step 2. 7.
AT-FS21x and AT-FS212/x Series Installation Guide 8. If your switch is shipped with an Single Voltage Power Adapter (single cable), do the following: a. Plug the DC cable into the DC receptacle on the switch. b. Plug the AC power cord to a power outlet. Note To prevent the DC power cable from being inadvertently pulled out of the switch, use the cable tie supplied with the unit to secure the DC power cable to the cable hook located next to the DC connector. 9.
Chapter 3 Troubleshooting Follow the guidelines below to test and troubleshoot the installation in the event a problem occurs. If the PWR LED is OFF, do the following: ❑ Make sure that the power adapter is securely connected to a power source and the DC power cord on the adapter is securely connected to the DC power connector on the switch. ❑ Verify that the power outlet has power by connecting another device to it. ❑ Try connecting the switch to another power source.
Troubleshooting ❑ Check to be sure that the end-node connected to the port is operating at 100 Mbps. ❑ Make sure that the fiber optic port on the end-node is operating in full-duplex mode. ❑ Make sure that the cable connected to the fiber optic receiver port on the switch is connected to the transmitter port on the remote end-node and that the fiber optic transmitter port on the switch is connected to the receiver port on the end-node.
Appendix A Technical Specifications Specifications Physical Dimensions: 90 mm x 24 mm x 70 mm (3.54 in x 0.94 in x 2.76 in) Weight: 0.23 kg (0.5 lbs) Temperature Operating: 0° to 40° C Storage: -25° to 70° C Relative Humidity: 5% to 80% (non-condensing) Operating Altitude: Up to 10,000 feet Electrical and Mechanical Specifications Standard: CE Compliant IEEE 802.3, IEEE 802.
Technical Specifications Electrical Rating Input Supply Voltage 3.3V DC Minimum Current Rating 1.5A Maximum Power Consumption 6W Fiber Optic Port Specifications The following tables list the specifications for the 100Base-FX fiber optic port. Table 5 Fiber Optic Transmitter Fiber Type1 Fiber Optic Diameter Optical Frequency AT-FS211 AT-FS212 AT-FS214 AT-FS215 AT-FS216 AT-FS217 MMF 50/125 MMF AT-FS212/1 Model Launch Power2 Maximum Average Minimum 1310 nm -14.0 -20.3 -22.5 62.
AT-FS21x and AT-FS212/x Series Installation Guide Table 6 Fiber Optic Receiver Receiver Power Fiber Type1 Fiber Optic Diameter Optical Frequency AT-FS211 AT-FS212 AT-FS214 AT-FS215 AT-FS216 AT-FS217 MMF 50/125 MMF AT-FS212/1 Model Minimum Typical Sensitivity Saturation 1310 nm -31.8 -34.5 -14.0 62.5/125 1310 nm -31.8 -34.5 -14.0 SMF 9/125 1310 nm -31.0 -31.0 -8.0 AT-FS212/2 SMF 9/125 1310 nm -35.0 -38.0 0.0 AT-FS212/3 SMF 9/125 1310 nm -37.0 -37.0 -3.
Technical Specifications Table 8 Fiber Optic Loss Specification (Benchmarks) Fiber Optic Diameter Optical Frequency Typical Loss Factor Worst Case Loss Factor Bandwidth Multimode Fiber 50/125 1310 nm 1.00 db/km 1.50 db/km 400 62.5/125 1310 nm 1.00 db/km 1.5 db/km 500 Single-mode 9/125 nm 1310 nm 0.40 db/km 1.00 db/km N/A 9/125 nm 1550 nm 0.30 db/km 0.75 db/km N/A Fiber Type Pinout Assignments Figure 7 shows the pin assignments of the switch’s 10/100Base-TX RJ-45 port.
Appendix B Electrical Safety and Installation Requirements Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Electrical Safety and Installation Requirements Standards: This product meets the following standards. U.S. Federal Communications Commission DECLARATION OF CONFORMITY Manufacture Name: Allied Telesyn International Corp.
AT-FS21x and AT-FS212/x Series Installation Guide $7 $8 Warning Class 1 Laser product. (AT-FS212/x models) Warning Do not stare into the Laser beam. At time of installation, the Fiber Optic Lasers comply with FDA Radiation Performance Standard 21CFR Subchapter J, applicable at date of manufacture. $9 ELECTRICAL NOTICES Warning: ELECTRIC SHOCK HAZARD To prevent ELECTRIC shock, do not remove the cover. No userserviceable parts inside.
Electrical Safety and Installation Requirements SICHERHEIT $7 Warnung Laserprodukt der Klasse 1. $8 Warnung Nicht direkt in den Strahl blicken. $9 Achtung: GEFÄHRLICHE SPANNUNG Das Gehäuse nicht öffnen. Das Gerät enthält keine vom Benutzer wartbaren Teile. Das Gerät steht unter Hochspannung und darf nur von qualifiziertem technischem Personal geöffnet werden. Vor Anschluß der LAN-Kabel, Gerät vom Netz trennen.
AT-FS21x and AT-FS212/x Series Installation Guide $9 ELEKTRISKE FORHOLDSREGLER Advarsel: RISIKO FOR ELEKTRISK STØD For at forebygge ELEKTRISK stød, undlad at åbne apparatet. Der er ingen indre dele, der kan repareres af brugeren. Denne enhed indeholder LIVSFARLIGE STRØMSPÆNDINGER og bør kun åbnes af en uddannet og kvalificeret tekniker. For at undgå risiko for ELEKTRISK STØD, afbrydes den elektriske strøm til produktet, før LAN-kablerne monteres eller afmonteres.
Electrical Safety and Installation Requirements STRØMSPÆNDINGER og bør kun åbnes af en uddannet og kvalificeret tekniker. For at undgå risiko for ELEKTRISK STØD, afbrydes den elektriske strøm til produktet, før LAN-kablerne monteres eller afmonteres. $ 10 Dit is een “KLASSE 1 LED-PRODUKT” $ 11 GEVAAR VOOR BLIKSEMINSLAG Gevaar: NIET aan toestellen of KABELS WERKEN bij BLIKSEM. $ 12 Attention: Le cordon d’alimentation sert de mise hors circuit.
AT-FS21x and AT-FS212/x Series Installation Guide être ouvert que par un technicien dûment qualifié. Pour éviter tout risque d’ÉLECTROCUTION, débrancher le matériel avant de connecter ou de déconnecter les câbles LAN. $ 10 Ce mat‚riel est un “PRODUIT A DIODE LECTROLUMINESCENTE DE CLASSE 1” $ 11 DANGER DE FOUDRE Danger: NE PAS MANIER le matériel ou les CÂBLES lors d'activité orageuse. $ 12 Attention: Le cordon d’alimentation sert de mise hors circuit.
Electrical Safety and Installation Requirements $ 11 SALAMANISKUVAARA ENGENVAARA: ÄLÄ TYÖSKENTELE laitteiden tai KAAPELEIDEN KANSSA SALAMOINNIN AIKANA. $ 12 HUOMAUTUS: VIRTAJOHTOA KÄYTETÄÄN VIRRANKATKAISULAITTEENA. VIRTA KATKAISTAAN irrottamalla virtajohto. $ 13 PISTORASIAAN KYTKETTÄVÄ LAITE; pistorasia on asennettava laitteen lähelle ja siihen on oltava esteetön pääsy.
AT-FS21x and AT-FS212/x Series Installation Guide $ 12 Attenzione: Il cavo di alimentazione è usato come dispositivo di disattivazione. Per togliere la corrente al dispositivo staccare il cavo di alimentazione. $ 13 APPARECCHIATURA COLLEGABILE, la presa va installata vicino all’apparecchio per risultare facilmente accessibile". $ 14 ATTENZIONE: le prese d’aria non vanno ostruite e devono consentire il libero ricircolo dell’aria ambiente per il raffreddamento.
Electrical Safety and Installation Requirements EUROPE - EU Benytt TÜV-godkjent AC-adapter på 3.3V DC, 1.5A (millismpere) $ 16 DRIFTSTEMPERATUR Dette produktet er konstruert for bruk i maksimum romtemperatur på 40 grader celsius. $ 17 ALLE LAND: Produktet må installeres i samsvar med de lokale og nasjonale elektriske koder. Padrões: Este produto atende aos seguintes padrões.
AT-FS21x and AT-FS212/x Series Installation Guide $ 16 TEMPERATURA DE FUNCIONAMENTO Este produto foi projetado para uma temperatura ambiente máxima de 40 graus centígrados. $ 17 TODOS OS PAÍSES: Instale o produto de acordo com as normas nacionais e locais para instalações elétricas. Estándares: Este producto cumple con los siguientes estándares.
Electrical Safety and Installation Requirements $ 17 PARA TODOS LOS PAÍSES: Monte el producto de acuerdo con los Códigos Eléctricos locales y nacionales. Standarder: Denna produkt uppfyller följande standarder. $1 Radiostörning $2 Varning: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder. $3 Immunitet $4 Varning! Denna produkt kräver skärmade kablar för att uppfylla standardkraven för emission och immunitet.
Appendix C Technical Support Fax Order Name _________________________________________________________________ Company ______________________________________________________________ Address _______________________________________________________________ City______________________ State/Province _______________________________ Zip/Postal Code ________________ Country_______________________________ Phone______________________________ Fax_______________________________ Incident Summary Model number of Allied