Fanless Gigabit Ethernet Switches AT-GS900/16 AT-GS900/24 Installation Guide 613-000891 Rev.
Copyright © 2007 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Microsoft and Internet Explorer are registered trademarks of Microsoft Corporation. Netscape Navigator is a registered trademark of Netscape Communications Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesis, Inc.
Electrical Safety and Emissions Standards This product meets the following standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Translated Safety Statements Important: The indicates that a translation of the safety statements is available in a PDF document titled “Translated Safety Statements” (613-000405) which is posted on the Allied Telesis website at www.alliedtelesis.com. This document is also included with the documentation CD that is shipped with the product.
Contents Preface ..................................................................................................................................................................................7 Safety Symbols Used in this Document..................................................................................................................................8 Where to Find Web-based Guides ...................................................................................................................
Contents 6
Preface This guide contains instructions on how to install the AT-GS900/16 and AT-GS900/24 Gigabit Ethernet Switches.
Preface Safety Symbols Used in this Document This document uses the safety symbols defined in Table 1. Table 1. Safety Symbols Symbol 8 Meaning Description Caution Performing or omitting a specific action may result in equipment damage or loss of data. Warning Performing or omitting a specific action may result in electrical shock.
AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide Where to Find Web-based Guides The installation and user guides for all Allied Telesis products are available in portable document format (PDF) on our web site at www.alliedtelesis.com. You can view the documents online or download them onto a local workstation or server.
Preface Contacting Allied Telesis This section provides Allied Telesis contact information for technical support as well as sales or corporate information. Online Support You can request technical support online by accessing the Allied Telesis Knowledge Base from the following web site: www.alliedtelesis.com/support. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide Management Software Updates New releases of management software for our managed products are available from either of the following Internet sites: Allied Telesis web site: www.alliedtelesis.com Allied Telesis FTP server: ftp://ftp.alliedtelesis.
Chapter 1 Product Description The AT-GS900/16 and AT-GS900/24 switches are unmanaged, Layer 2 Fanless Gigabit Ethernet switches designed to simplify the task of creating or expanding an Ethernet, Fast Ethernet, or Gigabit Ethernet network.
AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide Features AT-GS900/16 and AT-GS900/24 Fanless Gigabit Ethernet switches features include: 16 or 24 - RJ-45 10/100/1000 Mbps twisted pair ports System and port LEDs Auto MDI/MDI-X Auto-Negotiation 10/100/1000 Mbps full or half-duplex Back pressure and flow control at half-duplex and IEEE 802.
Chapter 1: Product Description Components Figure 1 illustrates the front panels of the AT-GS900/16 and AT-GS900/24 switches. AT-GS900/16 600 System / Port LEDS 16 - 10/100/1000Base Twisted Pair Ports AT-GS900/24 601 System / Port LEDS 24 - 10/100/1000Base Twisted Pair Ports Figure 1. Front Panels Figure 2 illustrates the back panels of the AT-GS900/16 and AT-GS900/24 switches. AT-GS900/16 100-240VAC 602 AC Power Connector AT-GS900/24 100-240VAC 603 AC Power Connector Figure 2.
AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide Hardware Feature Description The following sections describe hardware features of the AT-GS900/16 and AT-GS900/24 Fanless Gigabit Ethernet switches: Twisted Pair Ports System and Port LEDs Twisted Pair Ports AC Power Connector The AT-GS900/16 Fanless Gigabit Ethernet switch features 16 twisted pair ports, and the AT-GS900/24 Fanless Gigabit Ethernet switch features 24 twisted pair ports.
Chapter 1: Product Description Maximum Distance Each twisted pair port has a maximum operating distance of 100 m (328 feet). Type of Cabling For 10 Mbps operation, Category 3 or better 100 ohm shielded or unshielded twisted pair cabling is required. For 100 or 1000 Mbps operation, Category 5 and Enhanced Category 5 (5E) 100 ohm shielded or unshielded twisted pair cabling is required. Auto MDI/MDI-X All of the twisted pair ports on the switch are auto-MDI and IEEE 802.3abcompatible.
AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide Table 2 describes the system and port LEDs on the AT-GS900/16 and AT-GS900/24 switches. Table 2. System and Port LEDs LED POWER SPD/LINK/ ACT FDX/HDX AC Power Connector State Description Green The switch is powered ON and operating normally. OFF The switch has no power. Solid Green A valid 1000 Mbps link is established on the port. Solid Orange A valid 10 or 100 Mbps link is established on the port.
Chapter 1: Product Description Ethernet Switching Basics An Ethernet switch interconnects network devices, such as workstations, printers, routers, and other Ethernet switches, so that they can communicate with each other by sending and receiving Ethernet frames. MAC Address Table Every hardware device on your network has a unique MAC address. This address is assigned to the device by the device’s manufacturer.
AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide Duplex Mode Duplex mode refers to how an end-node receives and transmits data. If an end-node can either receive or transmit data, but not both simultaneously, the end-node is operating in what is referred to as half-duplex mode. If an end-node can both receive and transmit data simultaneously, the endnode is said to be operating in full-duplex mode.
Chapter 1: Product Description Network Topologies This section illustrates two network topologies that you can create with the AT-GS900/16 and AT-GS900/24 switches: a power workgroup and collapsed backbone. Both types of topologies are described below. Power Workgroup Topology The topology shown in Figure 4 is commonly referred to as a power workgroup topology. Each workstation or end-node is connected directly to a port on the switch.
AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide Collapsed Backbone In the topology illustrated in Figure 5, an AT-GS900/16 switch connects Fast Ethernet switches that have Gigabit Ethernet uplinks. This type of topology is often referred to as a collapsed backbone topology.
Chapter 2 Installation This chapter contains the following sections: “Reviewing Safety Precautions” on page 23 “Selecting a Site for the Switch” on page 24 “Planning the Installation” on page 25 “Unpacking the Switch” on page 26 “Installing the Switch on a Table or Desktop” on page 27 “Installing the Switch on a Wall” on page 29 “Installing the Switch in a Rack” on page 32 “Cabling the Switch” on page 35 “Powering On the Switch” on page 36 22
AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide Reviewing Safety Precautions Please review the following safety precautions before you begin to install the switch or any of its components. Refer to the “Translated Safety Statements” document for translated safety statements in your language. The indicates that a translation of the safety statement is available in a PDF document titled “Translated Safety Statements” (613-000405) on the Allied Telesis website at www.
Chapter 2: Installation Selecting a Site for the Switch Observe the following requirements when choosing a site for your switch: If you plan to install the switch in an equipment rack, ensure that the rack is safely secured and that it will not tip over. Devices in a rack should be installed starting at the bottom, with the heavier devices near the bottom of the rack. If you are installing the switch on a table, ensure that the table is level and secure.
AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide Planning the Installation Table 3 contains the cabling specifications for the twisted pair ports. Table 3.
Chapter 2: Installation Unpacking the Switch To unpack an AT-GS900/16 or an AT-GS900/24 switch, perform the following procedure: 1. Remove all components from the shipping package. Note Store the packaging material in a safe location. You must use the original shipping material if you need to return the unit to Allied Telesis. 2. Place the switch on a level, secure surface. 3. Ensure the following hardware components are included in your switch package.
AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide Installing the Switch on a Table or Desktop To install the switch on a table or desktop, perform the following procedure: 1. Remove all the items from the packaging and store the packaging material in a safe place. In the event a problem occurs and you need to return the unit, please use as much of the original shipping material as possible. 2.
Chapter 2: Installation Warning The power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord. E3 6. Verify that the POWER LED is green. If the LED is OFF, refer to “Troubleshooting” on page 37 for instructions. Note The switch perform a self-diagnostic test upon power up. This takes about 20 seconds to complete. 7. Power ON the end-nodes connected to the switch. 8. Check that all the SPD/LINK/ACT LEDs are green.
AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide Installing the Switch on a Wall To install the switch on a wall, perform the following procedure: 1. Remove all the items from the packaging and store the packaging material in a safe place. In the event a problem occurs and you need to return the unit, please use as much of the original shipping material as possible. 2.
Chapter 2: Installation 3. Place the switch on the wall. Then mount the switch using the #10-32 Phillips screws which are shipped with the product. See Figure 8. 1303 Figure 8. Attaching the switch to the wall 4. Connected the twisted pair cables to the twisted pair ports. When connecting a twisted pair cable to a port, observe the following guidelines: An RJ-45 connector should fit snugly into the port on the switch. The tab on the connector should lock the connector into place.
AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide 5. Apply power to the switch by plugging the AC/DC power adapter into an AC power outlet, the plug the DC connector to the power receptacle of the switch. Warning The power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord. E3 6. Verify that the POWER LED is green. If the LED is OFF, refer to “Troubleshooting” on page 37 for instructions.
Chapter 2: Installation Installing the Switch in a Rack Perform the following procedure to install the switch in a standard 19-inch rack. If you are not installing the switch in a rack, go to the next procedure. 1. Place the unit upside down on a level, secure surface. 2. Using a flat-head screwdriver, remove the self-adhesive rubber feet from the bottom of the switch, as shown in Figure 9. Figure 9. Removing the Feet 3. Turn the switch over. 4.
AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide 5. Mount the switch in the 19-inch rack using the #10-32 Phillips screws which are shipped with the product, as illustrated in Figure 11. 606 Figure 11. Rackmounting the Switch 6. Connected the twisted pair cables to the twisted pair ports. When connecting a twisted pair cable to a port, observe the following guidelines: An RJ-45 connector should fit snugly into the port on the switch.
Chapter 2: Installation 9. Power ON the end-nodes connected to the switch. 10. Check that all the SPD/LINK/ACT LEDs are green. If any of the LEDs are OFF, refer to “Troubleshooting” on page 37 for instructions. The switch is now ready for use.
AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide Cabling the Switch To connect to the ports on the AT-GS900/16 and AT-GS900/24 switches, perform the following procedure: 1. Connect the twisted pair data cables to the RJ-45 ports on the switch, as illustrated in Figure 12. 613 Figure 12. Connecting the Twisted Pair Data Cables 2. Power on the end-nodes. For more information, refer to “Powering On the Switch” on page 36.
Chapter 2: Installation Powering On the Switch To apply power to the AT-GS900/16 and AT-GS900/24 switches, perform the following procedure: 1. Apply AC power to the switch by plugging the power cord into the AC power connector on the back panel of the unit, as illustrated in Figure 13. Warning Power cord is used as a disconnection device: To de-energize equipment, disconnect the power cord. E3 100-2 40VA C~ 612 Figure 13. Connecting the AC Power Connector to Switch 2.
Chapter 3 Troubleshooting This chapter contains information on how to troubleshoot the switch in the event that a problem occurs. Note If you are still unable to resolve the problem after following the instructions in this chapter, contact ATI Technical Support for assistance. Refer to “Contacting Allied Telesis” on page 10. Check the POWER LED on the front of the switch.
Appendix A Technical Specifications Physical Specifications Dimensions: AT-GS900/16 (W x D x H) 330 mm x 230.5 mm x 43 mm (13.0 in x 9.07 in x 1.7 in) AT-GS900/24 330 mm x 230.5 mm x 43 mm (13.0 in x 9.07 in x 1.7 in) Weight: AT-GS900/16 AT-GS900/24 2.38 kg (5.25 lbs) 2.99 kg (6.
AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide Safety and Electromagnetic Emissions Certifications EMI FCC Class A, CISPR 22 Class A, EN55022 Class A, C-TICK Immunity EN55024 Safety UL 60950 (CULUS), EN60950-1 (TUV) Quality and Reliability: AT-GS900/16 MTBF – 280,000 hours AT-GS900/24 MTBF – 230,000 hours Compliance Standards IEEE 802.3 – 10Base-T IEEE 802.3u – 100Base-TX IEEE 802.3ab – 1000Base-TX Gigabit Ethernet IEEE 802.3z – Full Duplex IEEE 802.
Appendix A: Technical Specifications Table 4 lists the RJ-45 pin signals when a twisted pair port is operating in the MDI configuration. Table 4. MDI Pin Signals (10Base-T or 100Base-TX) Pin Signal 1 TX+ 2 TX- 3 RX+ 6 RX- Table 5 lists the RJ-45 port pin signals when a twisted pair port is operating in the MDI-X configuration. Table 5.