Gigabit eco-friendly Ethernet Switches AT-GS900/16 AT-GS900/24 Installation Guide 613-001351 Rev.
Copyright © 2010 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated.
Electrical Safety and Emissions Standards This product meets the following standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Translated Safety Statements Important: The symbol indicates that a translation of the safety statement is available in a PDF document titled “Translated Safety Statements”. This is posted on the Allied Telesis website at http://www.alliedtelesis.com/support/software/. Refer to “Where to Find Web-based Product Documentation” on page 13 to navigate to this document.
Contents Preface ............................................................................................................................................................ 11 Safety Symbols Used in this Document ..................................................................................................... 12 Where to Find Web-based Guides............................................................................................................. 13 Contacting Allied Telesis........................
Contents 6
Figures Figure 1. Front Panels .........................................................................................................................................................18 Figure 2. Back Panels .........................................................................................................................................................18 Figure 3. eco-friendly Switch .....................................................................................................................
Figures 8
Tables Table 1. Table 2. Table 3. Table 4. Table 5. Table 6. Table 7. Safety Symbols .....................................................................................................................................................12 eco-friendly Switch Functions ...............................................................................................................................21 System and Port LEDs .............................................................................................
List of Tables 10
Preface This guide contains instructions on how to install the AT-GS900/16 and AT-GS900/24 Gigabit Ethernet Switches.
Preface Safety Symbols Used in this Document This document uses the safety symbols defined in Table 1. Table 1. Safety Symbols Symbol 12 Meaning Description Caution Performing or omitting a specific action may result in equipment damage or loss of data. Warning Performing or omitting a specific action may result in electrical shock.
AT-GS900/16, AT-GS900/24 Gigabit eco-friendly Ethernet Switch Installation Guide Where to Find Web-based Guides The product documentation for all Allied Telesis products are available in portable document format (PDF) on our web site. Go to http://www.alliedtelesis.com/support/software/. Enter your hardware product model in the Search by Product Name field; for example, enter AT-GS900/16 or AT-GS900/24. You can view the documents online or download them onto your local workstation or server.
Preface Contacting Allied Telesis This section provides Allied Telesis contact information for technical support as well as sales and corporate information. Online Support You can request technical support online by accessing the Allied Telesis Knowledge Base: www.alliedtelesis.com/support/kb.aspx. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
AT-GS900/16, AT-GS900/24 Gigabit eco-friendly Ethernet Switch Installation Guide 15
Chapter 1 Product Description The AT-GS900/16 and AT-GS900/24 switches are low operating power, unmanaged, Layer 2 Fanless Gigabit Ethernet switches designed to simplify the task of creating or expanding an Ethernet, Fast Ethernet, or Gigabit Ethernet network.
AT-GS900/16, AT-GS900/24 Gigabit eco-friendly Ethernet Switch Installation Guide Features AT-GS900/16 and AT-GS900/24 Gigabit eco-friendly Ethernet switches features include: Silent fanless operation Power saving port features on each port including: – Cable Length detection and power minimization – Link-Down power savings LED disable mode 16 or 24 x 10/100/1000Mbps auto-sensing, switching ports MAC address table: – AT-GS900/16: Up to 8K MAC address table – AT-GS900/24: Up to 1
Chapter 1: Product Description Components Figure 1 illustrates the front panels of the AT-GS900/16 and AT-GS900/24 switches.
AT-GS900/16, AT-GS900/24 Gigabit eco-friendly Ethernet Switch Installation Guide Hardware Feature Description The following sections describe hardware features of the AT-GS900/16 and AT-GS900/24 Fanless Gigabit Ethernet switches: Twisted Pair Ports System and Port LEDs Twisted Pair Ports AC Power Connector The AT-GS900/16 Fanless Gigabit Ethernet switch features 16 twisted pair ports, and the AT-GS900/24 Fanless Gigabit Ethernet switch features 24 twisted pair ports.
Chapter 1: Product Description Maximum Distance Each twisted pair port has a maximum operating distance of 100 m (328 feet). Type of Cabling For 10 Mbps operation, Category 3 or better 100 ohm shielded or unshielded twisted pair cabling is required. For 100 or 1000 Mbps operation, Category 5 and Enhanced Category 5 (5E) 100 ohm shielded or unshielded twisted pair cabling is required. Auto MDI/MDI-X All of the ports on the switch are auto-MDI and IEEE 802.3ab-compatible.
AT-GS900/16, AT-GS900/24 Gigabit eco-friendly Ethernet Switch Installation Guide eco-friendly Switch The eco-friendly switch on the front panel is multi-functional and shown in Figure 3. It may be used to enable all the port LEDs (out position) or conserve power by turning off the port LEDs (in position). The switch functions are described in Table 2. POW 1902 Figure 3. eco-friendly Switch Table 2. eco-friendly Switch Functions Action Results OFF (Out position) All front panel LEDs are enabled.
Chapter 1: Product Description Table 3 describes the system and port LEDs on the AT-GS900/16 and AT-GS900/24 switches. Table 3. System and Port LEDs LED POWER L/A D/C AC Power Connector State Description Green The switch is powered ON and operating normally. OFF The switch has no power. Solid Green A valid 1000 Mbps link is established on the port. Solid Orange A valid 10 or 100 Mbps link is established on the port.
AT-GS900/16, AT-GS900/24 Gigabit eco-friendly Ethernet Switch Installation Guide Ethernet Switching Basics An Ethernet switch interconnects network devices, such as workstations, printers, routers, and other Ethernet switches, so that they can communicate with each other by sending and receiving Ethernet frames. MAC Address Table Every hardware device on your network has a unique MAC address. This address is assigned to the device by the device’s manufacturer.
Chapter 1: Product Description the end-node is operating in what is referred to as half-duplex mode. If an end-node can both receive and transmit data simultaneously, the endnode is said to be operating in full-duplex mode. Naturally, an end-node capable of operating in full-duplex can handle data much faster than an end-node that can only operate in half-duplex mode.
AT-GS900/16, AT-GS900/24 Gigabit eco-friendly Ethernet Switch Installation Guide 25
Chapter 2 Installation This chapter contains the following sections: “Reviewing Safety Precautions” on page 27 “Enter your hardware product model in the Search by Product Name field; for example, enter AT-GS900/16 or AT-GS900/24. You can view the documents online or download them onto your local workstation or server.
AT-GS900/16, AT-GS900/24 Gigabit eco-friendly Ethernet Switch Installation Guide Reviewing Safety Precautions Please review the following safety precautions before you begin to install the switch or any of its components.The indicates that a translation of the safety statements is available in a PDF document titled “Translated Safety Statements”. This other product documentation is posted on the Allied Telesis website at http://www.alliedtelesis.com/support/ software/.
Chapter 2: Installation Caution: Air vents must not be blocked and must have free access to the room ambient air for cooling. E8 Warning: Operating Temperature. This product is designed for a maximum ambient temperature of 40° degrees C. E9 All Countries: Install product in accordance with local and National Electrical Codes. E10 Warning: Mounting of the equipment in the rack should be such that a hazardous condition is not created due to uneven mechanical loading.
AT-GS900/16, AT-GS900/24 Gigabit eco-friendly Ethernet Switch Installation Guide Selecting a Site for the Switch Observe the following requirements when choosing a site for your switch: If you plan to install the switch in an equipment rack, ensure that the rack is safely secured and that it will not tip over. Devices in a rack should be installed starting at the bottom, with the heavier devices near the bottom of the rack.
Chapter 2: Installation Planning the Installation Table 4 contains the cabling specifications for the twisted pair ports. Table 4.
AT-GS900/16, AT-GS900/24 Gigabit eco-friendly Ethernet Switch Installation Guide Unpacking the Switch To unpack an AT-GS900/16 or an AT-GS900/24 switch, perform the following procedure: 1. Remove all components from the shipping package. Note Store the packaging material in a safe location. You must use the original shipping material if you need to return the unit to Allied Telesis. 2. Place the switch on a level, secure surface. 3.
Chapter 2: Installation Installing the Switch on a Table or Desktop To install the switch on a table or desktop, perform the following procedure: 1. Remove all the items from the packaging and store the packaging material in a safe place. In the event a problem occurs and you need to return the unit, please use as much of the original shipping material as possible. 2. Attach the four self-adhesive rubber feet to the bottom of the switch, as shown in Figure 5.
AT-GS900/16, AT-GS900/24 Gigabit eco-friendly Ethernet Switch Installation Guide 5. Apply AC power to the switch by plugging the power cord into the AC power connector on the back panel of the unit, as illustrated in Figure 6. 100-2 40VA C~ 612 Figure 6. Connecting the AC Power Connector to Switch 6. Plug the other end or the power cord into a wall outlet. 7. Verify that the POWER LED is green. If the LED is OFF, refer to “Troubleshooting” on page 41 for instructions.
Chapter 2: Installation Installing the Switch on a Wall To install the switch on a wall, perform the following procedure: 1. Remove all the items from the packaging and store the packaging material in a safe place. In the event a problem occurs and you need to return the unit, please use as much of the original shipping material as possible. 2. Attach the two mounting brackets (provided) to the sides of the switch using the eight flathead Phillips screws (provided), as illustrated in Figure 7.
AT-GS900/16, AT-GS900/24 Gigabit eco-friendly Ethernet Switch Installation Guide 3. Place the switch on the wall. Then mount the switch using the plastic anchors and screws which are shipped with the product. See Figure 8. Warning The switch must be mounted with the AC Power Connector facing down to conform with UL requirements as shown in Figure 8.
Chapter 2: Installation crossover twisted pair cable to connect any type of network device to a port on the switch. If you disable Auto-Negotiation on the port, the port defaults to MDI-X. 5. Apply AC power to the switch by plugging the power cord into the AC power connector on the back panel of the unit, as illustrated in Figure 6 on page 33. 6. Plug the other end or the power cord into a wall outlet. 7. Verify that the POWER LED is green.
AT-GS900/16, AT-GS900/24 Gigabit eco-friendly Ethernet Switch Installation Guide Installing the Switch in a Rack Perform the following procedure to install the switch in a standard 19-inch rack. If you are not installing the switch in a rack, go to the next procedure. 1. Place the unit upside down on a level, secure surface. 2. If they have been previously installed, remove the self-adhesive rubber feet from the bottom of the switch, as shown in Figure 9 using a flathead screwdriver. Figure 9.
Chapter 2: Installation 5. Mount the switch in the 19-inch rack using the #10-32 Phillips screws which are shipped with the product, as illustrated in Figure 11. 24 Port 10/100/1 000B 1 POWER ase-T 3 AT-G S9 00/24 Gigabit Ethernet Switch 5 7 9 11 13 15 17 19 1 21 23 3 5 2 4 7 6 8 10 12 1000 LINK 9 14 16 18 ACT 10/10 0 LINK 11 20 22 ACT 13 24 FDX 15 2 HDX COL 17 4 19 6 21 8 23 10 12 14 16 18 20 22 24 1921 Figure 11. Rack Mounting the Switch 6.
AT-GS900/16, AT-GS900/24 Gigabit eco-friendly Ethernet Switch Installation Guide 10. Power ON the end-nodes connected to the switch. 11. Check that all the L/A LEDs are green or blinking green for the ports connected to end-nodes. If any of the LEDs are OFF, refer to “Troubleshooting” on page 41 for instructions. The switch is now ready for use.
Chapter 2: Installation 40
Chapter 3 Troubleshooting This chapter contains information on how to troubleshoot the switch in the event that a problem occurs. Note If you are still unable to resolve the problem after following the instructions in this chapter, contact ATI Technical Support for assistance. Refer to “Contacting Allied Telesis” on page 14. Check the POWER LED on the front of the switch.
Appendix A Technical Specifications Physical Specifications Dimensions: AT-GS900/16 AT-GS900/24 Weight: AT-GS900/16 AT-GS900/24 (W x D x H) 12.1 cm x 18.4 cm x 4.4 cm (4.7 in x 7.2 in x 1.7 in) 28 cm x 18 cm x 4.4 cm (11.0 in x 7.1 in x 1.7 in) 0.954kg (2.1 lbs) 1.794 kg (3.
AT-GS900/16, AT-GS900/24 Gigabit eco-friendly Ethernet Switch Installation Guide Safety and Electromagnetic Emissions Certifications EMI FCC Part 15 Class A CISPR 22 Class A, EN55022 Class A: 2006 + A1:2007 version Immunity EN55024 Safety UL - USA (UL60950-1) LVD (EN60950-1, 2nd edition) CSA or CUL - Canada C-Tick - Australia CD Mark Environment Compliance Eu-RoHS compliant WEEE China RoHS compliant Quality and Reliability: AT-GS900/16 MTBF: AT-GS900/24 MTBF: >50,000 hours @ 25 C >50,000 hours @
Chapter : Technical Specifications RJ-45 Twisted Pair Port Connectors This section lists the connectors and connector pinouts for the AT-GS900/16 and AT-GS900/24 Fanless Gigabit Ethernet Switches and their components. Figure 12 illustrates the pin layout to an RJ-45 connector and port. 1 8 8 1 Figure 12. RJ-45 Connector and Port Pin Layout Table 5 lists the RJ-45 pin signals when a twisted pair port is operating in the MDI configuration. Table 5.
AT-GS900/16, AT-GS900/24 Gigabit eco-friendly Ethernet Switch Installation Guide 1000Base-T port is operating at 1000 Mbps. Table 7. RJ-45 1000Base-T Connector Pinoutsa Pin Pair Signal 1 1 TX and RX+ 2 1 TX and RX- 3 2 TX and RX+ 4 3 TX and RX+ 5 3 TX and RX- 6 2 TX and RX- 7 4 TX and RX+ 8 4 TX and RX- a. Bi-directional data on each pair.