Gigabit Ethernet Switches AT-GS916 AT-GS924 Installation Guide PN 613-50572-00 Rev A ®
Copyright © 2004 Allied Telesyn, Inc. www.alliedtelesyn.com All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn, Inc. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn, Inc. reserves the right to make changes in specifications and other information contained in this document without prior written notice.
Electrical Safety and Emission Statement Standards: This product meets the following standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Table of Contents Electrical Safety and Emission Statement ............................................................................................................................................... 3 Preface ...................................................................................................................................................................................................................... 6 How This Guide is Organized .....................................................
Chapter 3 Troubleshooting ................................................................................................................................................................................................33 Appendix A Technical Specifications .................................................................................................................................................................................35 Physical Specifications ...................................................
Preface This guide contains the hardware installation instructions for the AT-GS916 and AT-GS924 Gigabit Ethernet Switches. How This Guide is Organized This manual contains the following chapters and appendices: Chapter 1, ”Product Description”, describes the features and components of the switches. Chapter 2, ”Installation”, contains the installation instructions for the switches. Chapter 3, ”Troubleshooting”, provides information on how to resolve problems that might occur with the switches.
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide Document Conventions This document uses the following conventions to highlight important information: Note Notes provide additional information. Warning Warnings inform you that performing or omitting a specific action may result in bodily injury. Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data.
Preface Contacting Allied Telesyn This section provides Allied Telesyn contact information for technical support as well as sales or corporate information. Online Support Email and Telephone Support Returning Products You can request technical support online by accessing the Allied Telesyn Knowledge Base from the following web site: http://kb.alliedtelesyn.com. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
Chapter 1 Product Description The AT-GS916 and AT-GS924 switches are unmanaged, Layer 2 Gigabit Ethernet switches designed to simplify the task of creating or expanding an Ethernet, Fast Ethernet, or Gigabit Ethernet network.
Product Description Features AT-GS916 and AT-GS924 Gigabit Ethernet switches features include: 16 or 24 - 10/100/1000 Mbps twisted pair ports System and port LEDs Auto MDI/MDI-X Auto-Negotiation (IEEE 802.3u-compliant) 10/100 Mbps full or half-duplex, and 1000 Mbps full duplex Back pressure and flow control (IEEE 802.
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide Components Figure 1 illustrates the front panels of the AT-GS916 and AT-GS924 switches.
Product Description Hardware Feature Description The following sections describe hardware features of the AT-GS916 and AT-GS924 Gigabit Ethernet switches: System and Port LEDs Twisted Pair Ports AC Power Connector Twisted Pair Ports The AT-GS916 Gigabit Ethernet switch features 16 twisted pair ports, and the AT-GS924 Gigabit Ethernet switch features 24 twisted pair ports. Type of Connector The twisted pair ports feature 8-pin RJ-45 connectors.
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide Auto MDI/MDI-X All of the twisted pair ports on the switch are auto-MDI and IEEE 802.3ab-compatible. When a port's speed and duplex mode are set through Auto-Negotiation, the port uses the auto-MDI feature to automatically configure itself as MDI or MDI-X when connected to an end-node. Consequently, you can use either a straight-through or crossover twisted pair cable when connecting any network device to a port.
Product Description Table 1 System and Port LEDs LED State Description ACT Green A valid link has been established between the port and the end-node. Flashing Green The port is transmitting and/or receiving data packets. OFF There is no link established between the port and the end-node. Green The port is operating in full-duplex mode. OFF The port is operating in half-duplex mode.
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide A Few Ethernet Switching Basics An Ethernet switch interconnects network devices, such as workstations, printers, routers, and other Ethernet switches, so that they can communicate with each other by sending and receiving Ethernet frames. MAC Address Table Every hardware device on your network has a unique MAC address. This address is assigned to the device by the device’s manufacturer.
Product Description If the switch receives a packet with a destination address that is on the same port on which the packet was received, it discards the packet without forwarding it on to any port. Since both the source end-node and the destination end-node for the packet are located on the same port on the switch, there is no reason for the switch to forward the packet. Duplex Mode Duplex mode refers to how an end-node receives and transmits data.
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide A port operating in full-duplex mode uses PAUSE frames, as specified in the IEEE 802.3x standard, to stop the transmission of data from an endnode. Whenever the switch wants an end-node to stop transmitting data, it issues this frame. The frame instructs the end-node to cease transmission for a period of time specified within the frame. The switch continues to issue PAUSE frames until it is ready again to receive data from the end-node.
Product Description Network Topologies This section illustrates two network topologies that you can create with the AT-GS916 Gigabit Ethernet switch: a power workgroup and collapsed backbone. Both types of topologies are described below. Power Workgroup Topology The topology shown in Figure 4 is commonly referred to as a power workgroup topology. Each workstation or end-node is connected directly to a port on the switch.
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide Collapsed Backbone In the topology illustrated in Figure 5, an AT-GS916 switch connects Fast Ethernet switches that have Gigabit Ethernet uplinks. This type of topology is often referred to as a collapsed backbone topology.
Chapter 2 Installation This chapter contains the following sections: ”Reviewing Safety Precautions” on page 21 ”Selecting a Site for the Switch” on page 22 ”Planning the Installation” on page 23 ”Unpacking the Switch” on page 24 ”Installing the Power Cord Retaining Clip” on page 25 ”Installing the Switch in a Rack” on page 27 ”Cabling the Switch” on page 29 ”Powering On the Switch” on page 30 ”Warranty Registration” on page 32 20
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide Reviewing Safety Precautions Please review the following safety precautions before you begin to install the switch or any of its components. Refer to ”” on page 39 for translated safety statements in your language. Warning Electric Shock Hazard: To prevent electric shock, do not remove the cover. There are no user-serviceable parts inside. The unit contains hazardous voltages and should only be opened by a trained and qualified technician.
Installation Selecting a Site for the Switch Observe the following requirements when choosing a site for your switch: If you plan to install the switch in an equipment rack, ensure that the rack is safely secured and that it will not tip over. Devices in a rack should be installed starting at the bottom, with the heavier devices near the bottom of the rack. If you are installing the switch on a table, ensure that the table is level and secure.
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide Planning the Installation Table 2 contains the cabling specifications for the twisted pair ports.
Installation Unpacking the Switch To unpack an AT-GS916 or an AT-GS924 switch, perform the following procedure: 1. Remove all components from the shipping package. Note Store the packaging material in a safe location. You must use the original shipping material if you need to return the unit to Allied Telesyn. 2. Place the switch on a level, secure surface. 3. Ensure the following hardware components are included in your switch package.
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide Installing the Power Cord Retaining Clip Perform the following procedure to install the power cord retaining clip on an AC powered switch: Note Install the power cord retaining clip before you install the switch in a rack. 1. Locate the power cord retaining clip which is shown in Figure 6. Figure 6. Power Cord Retaining Clip 2.
Installation 4. Verify that the retaining clip is in the correct position, as shown in Figure 9. 100-2 40VA C~ Figure 9.
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide Installing the Switch in a Rack Perform the following procedure to install the switch in a standard 19-inch rack. If you are not installing the switch in a rack, go to the next procedure. 1. Place the unit upside down on a level, secure surface. 2. Using a flat-head screwdriver, remove the snap-on plastic feet from the bottom of the switch, as shown in Figure 10. Figure 10. Removing the Feet 3. Turn the switch over. 4.
Installation 5. Mount the switch in the 19-inch rack using the rackmounting screws (provided), as illustrated in Figure 12.
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide Cabling the Switch To connect to the ports on the AT-GS916 and AT-GS924 switches, perform the following procedure: 1. Connect the twisted pair data cables to the RJ-45 ports on the switch, as illustrated in Figure 13. 10 100 1000 13 14 ACT 15 16 FDX 1 3 5 7 2 4 6 8 Figure 13 Connecting the Twisted Pair Data Cables 2. Power on the end-nodes. For more information, refer to ”Powering On the Switch” on page 30.
Installation Powering On the Switch To apply power to the AT-GS916 and AT-GS924 switches, perform the following procedure: 1. Position the power cord retaining clip in the UP position, as illustrated in Figure 14. 100-2 40VA C~ Figure 14 Power Cord Retaining Clip in the UP Position 2. Apply AC power to the switch by plugging the power cord into the AC power connector on the back panel of the unit, as illustrated in Figure 15.
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide 3. Secure the cord by lowering the power cord retaining clip, as illustrated in Figure 16. 100-2 40VA C~ Figure 16 Securing the Power Cord with the Retaining Clip 4. Plug the other end or the power cord into a wall outlet. 5. Verify that the POWER LED is green. If the LED is OFF, refer to ”Troubleshooting” on page 33. The switch is ready for network operations.
Installation Warranty Registration After installing your switch, you can register your product by completing the enclosed warranty card and sending it to Allied Telesyn.
Chapter 3 Troubleshooting This chapter contains information on how to troubleshoot the switch in the event that a problem occurs. Note If you are still unable to resolve the problem after following the instructions in this chapter, contact ATI Technical Support for assistance. Refer to ”Contacting Allied Telesyn” on page 8. Check the PWR LED on the front of the switch.
Troubleshooting Verify that you are using the appropriate category of twisted pair cable: Category 3 or better for 10 Mbps operation and Category 5 and Category 5E for 100 and 1000 Mbps operation. Note A 1000Base connection can take from five to ten seconds for the link to be established.
Appendix A Technical Specifications Physical Specifications Dimensions: AT-GS916 (W x D x H) 33.02 cm x 22.86 cm x 4.42 cm (13.0 in x 9.0 in x 1.74 in) AT-GS924 44.05 cm x 22.35 cm x 4.37 cm (17.34 in x 8.80 in x 1.72 in) Weight: AT-GS916 AT-GS924 2.38 kg (5.25 lbs) 2.99 kg (6.
Technical Specifications Power Specifications Power Consumption: AT-GS916 AT-GS924 32 watts maximum 50 watts maximum AC Input Electrical Ratings: AC100 - 240 VAC, 2A Frequency: 50/60 Hz Safety and Electromagnetic Emissions Certifications 36 Safety: EN60950 (TUV), UL60950 (cULus), CE EMI: FCC Class A, EN55022 Class A, VCCI Class A, C-TICK Immunity: EN55024 Quality and Reliability: MTBF – 558,000 hours
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide Connectors This section lists the connectors and connector pinouts for the AT-GS916 and AT-GS924 Gigabit Ethernet switches and their components. RJ-45 Twisted Pair Port Pinouts Figure 17 illustrates the pin layout to an RJ-45 connector and port. 1 8 8 1 Figure 17 RJ-45 Connector and Port Pin Layout Table 3 lists the RJ-45 pin signals when a twisted pair port is operating in the MDI configuration.
Technical Specifications Table 5 lists the RJ-45 connector pins and their signals when a 1000Base-T port is operating at 1000 Mbps. Table 5 RJ-45 1000Base-T Connector Pinouts1 Pin Pair Signal 1 1 TX and RX+ 2 1 TX and RX- 3 2 TX and RX+ 4 3 TX and RX+ 5 3 TX and RX- 6 2 TX and RX- 7 4 TX and RX+ 8 4 TX and RX- 1. Bi- directional data on each pair.
Appendix B Translated Electrical Safety and Emission Information Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Translated Electrical Safety and Emission Information Standards: This product meets the following standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. 1 Hochfrequenzstörung 2 WARNUNG: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen.
Translated Electrical Safety and Emission Information Standarder: Dette produkt tilfredsstiller de følgende standarder. 1 Radiofrekvens forstyrrelsesemission FCC Klasse A, EN55022 Klasse A, VCCI Class A, C-TICK 2 ADVARSEL: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger.
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide Eisen: Dit product voldoet aan de volgende eisen. 1 RFI Emissie 2 WAARSCHUWING: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen.
Translated Electrical Safety and Emission Information Normes: ce produit est conforme aux normes de suivantes: 1 Emission d’interférences radioélectriques FCC Classe A, EN55022 Classe A, VCCI Class A, C-TICK 2 MISE EN GARDE : dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates.
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide Standardit: Tämä tuote on seuraavien standardien mukainen. 1 Radioaaltojen häirintä 2 VAROITUS: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin.
Translated Electrical Safety and Emission Information Standard: Questo prodotto è conforme ai seguenti standard. 1 Emissione RFI (interferenza di radiofrequenza) FCC Classe A, EN55022 Classe A, VCCI Class A, C-TICK 2 AVVERTENZA: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati provvedimenti.
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. 1 RFI stråling 2 ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler.
Translated Electrical Safety and Emission Information Padrões: Este produto atende aos seguintes padrões. 1 Emissão de interferência de radiofrequência FCC Classe A, EN55022 Classe A, VCCI Class A, C-TICK 2 AVISO: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas.
AT-GS916 and AT-GS924 Gigabit Ethernet Switches Installation Guide Estándares: Este producto cumple con los siguientes estándares. 1 Emisión RFI 2 ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto.
Translated Electrical Safety and Emission Information Standarder: Denna produkt uppfyller följande standarder. 1 Radiostörning 2 VARNING: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder.