User Guide
How to Start an AT-GS950/24 WEB Management Session
31
Caution
Since you define this password as part of the process of disabling 
this function, Allied Telesis has no knowledge of it. You are 
responsible for keeping the password in a safe place. If it is lost, 
Allied Telesis does not have a way to help you recover it.
See “Disabling Factory Default Reset Feature” on page 34 for information 
about how to disable the factory default reset feature.
Switch Reboot The following procedure outlines how to reboot your AT-GS950/24 switch. 
Caution
This procedure reboots the switch and reloads the AT-S109 
Management software configuration from flash memory. Insure that 
your current configuration is saved before rebooting the switch by 
selecting Save Configuration to Flash from the main menu on the 
left side of the page to permanently save your changes. 
All configuration parameters that have not been previously saved 
are lost. After the switch is reboots, they are reset to the values 
stored in the flash memory.
Caution
This procedure causes the switch to reboot. The switch does not 
forward network traffic during the reboot process. Some network 
traffic may be lost. 
1. From the main menu on the left side of the page, select the Tools 
folder.
The Tools folder expands.
2. From the Tools folder, select Reboot.
The Factory Default Reset/Reboot Page is displayed. See Figure 14.










