AT-MC1001 AT-MC1001SC/GS2 AT-MC1001SC/GS3 AT-MC1001SC/GS4 Gigabit Media Converters Installation Guide PN 613-10831-00 Rev B
Copyright 2000 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA USA 94085 All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn International, Corp.
Safety Warnings Standards: This product meets the following standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Table of Contents Safety Warnings ............................................................................................ iii Welcome to Allied Telesyn ......................................................................... vii Where to Find Web-based Guides ................................................................... vii Document Conventions .................................................................................... vii Contacting Allied Telesyn .....................................
Appendix A Translated Safety Statements ................................................................... 19 Appendix B AT-MC1001 Series Installation Guide Feedback .................................. 31 Appendix C Technical Support Fax Order ................................................................... 33 Incident Summary ............................................................................................
Welcome to Allied Telesyn This guide contains instructions on how to install an AT-MC1001 Series Gigabit Media Converter. Where to Find Web-based Guides The Allied Telesyn web site at www.alliedtelesyn.com provides you with an easy way to access the most recent documentation and technical information for all of our products. All web-based documents relating to this product and other Allied Telesyn products can be downloaded from the web site in PDF format.
Contacting Allied Telesyn There are several ways to contact Allied Telesyn technical support: online, telephone, fax or e-mail. Online Support You can request technical support online by filling out the Online Technical Support Form at www.alliedtelesyn.com/forms/support.htm.
AT-MC1001 Series Installation Guide Returning Products Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense.
For Sales or Corporate Information Allied Telesyn International, Corp. 19800 North Creek Parkway, Suite 200 Bothell, WA 98011 Tel: 1 (425) 487-8880 Fax: 1 (425) 489-9191 Allied Telesyn International, Corp.
AT-MC1001 Series Gigabit Media Converters The AT-MC1001 Series Gigabit Media Converters include the following models: ❑ AT-MC1001 ❑ AT-MC1001SC/GS3 ❑ AT-MC1001SC/GS2 ❑ AT-MC1001SC/GS4 The AT-MC1001 Series Gigabit Media Converters are designed to extend the distance of your network by converting Ethernet data between multimode and single-mode fiber optic cables. Each media converter features a 1000Base-SX port and a 1000Base-LX port.
Table 1 list the cabling distances for the AT-MC1001 Series Gigabit Media Converters. Table 1 Maximum Cabling Distances 1000Base-LX Model Type of Connector Maximum Distance1 1000Base-SX Type of Connector Maximum Distance2 AT-MC1001 SC 10 km (6.2 mi) SC 550 m (1,804 ft) AT-MC1001SC/GS2 SC 20 km (12.4 mi) SC 550 m (1,804 ft) AT-MC1001SC/GS3 SC 50 km (31 mi) SC 550 m (1,804 ft) AT-MC1001SC/GS4 SC 70 km (43.4 mi) SC 550 m (1,804 ft) 1.
AT-MC1001 Series Installation Guide 1000Base-SX Port The 1000Base-SX port has an SC connector and is designed to operate with multimode fiber optic cabling. The port has a maximum distance of 275 (902 feet) meters using 62.5/125 micron multimode fiber optic cable and 550 meters (1,804 feet) using 50/125 micron multimode fiber optic cable. 1000Base-LX Port The 1000Base-LX fiber optic port has an SC connector and is designed to operate with multimode or single-mode fiber optic cable.
Link Test Standalone/Back to Back Button CLASS 1 LASER PRODUCT DO NOT STARE INTO BEAM LK TST STAD ALOE LK TST BACK TO BACK TX RX Link Test/MissingLink Switch 1000Base-LX TX RX LNK TST PWR M/L ON SINGLE MODE LNK 1000Base-SX MULTI MODE LNK M/L ON MC1001SC/GS2 GIGABIT ETHERNET MEDIA CONVERTER Figure 2 Link Test and Topology Features Link Test/MissingLink Switch The Link Test/MissingLink switch (see Figure 2) allows you to perform a link test on the ports on the media converter.
AT-MC1001 Series Installation Guide MissingLink. The MissingLink feature enables the fiber optic ports on the media converter to pass the “Link” status of their connections to each other. When the media converter detects a problem with one of the ports, such as the loss of connection to a node, the media converter shuts down the connection to the other port, thus notifying the node that the connection has been lost.
Link Test Standalone/Back to Back Button The Link Test Standalone/Back to Back button (see Figure 2) is used together with the Link Test/MissingLink switch. When performing a link test on the media converter, use this switch to configure the unit to match the topology in which you installed the media converter. The two possible network topologies for the media converter, standalone and back to back, are described in the section “Network Topologies” on page 8.
AT-MC1001 Series Installation Guide External AC/DC Power Adapter The media converter comes with an external AC-to-DC power adapter (see Figure 4). The power adapter supplies 12 volts DC to the media converter. Allied Telesyn supplies an approved safety compliant AC power adapter for the 120 and 240 V AC versions with an unregulated output of 12 V DC at 1 A. The power required for the media converter is 12 V DC, 500 mA.
Network Topologies Standalone Topology A standalone topology refers to when there is only one media converter between the end nodes. Figure 5, for example, illustrates a standalone topology that uses two AT-MC1001 Series Media Converter to interconnect three remote campuses. Campus 1 has an AT-8224XL switch with two AT-A15/LX expansion modules. The modules, which provide a connection of up to 10 kilometers (6.2 miles), are connected to the 1000Base-LX ports on the media converter.
AT-MC1001 Series Installation Guide Back to Back Topology In some network configurations you may want to interconnect two media converters in what is referred to as a back to back topology (see Figure 6). In this topology, the AT-MC1001 Series Media Converters not only extend the distance of your network but also convert the fiber optic cable from multimode to single-mode and back again. The figure shows one AT-8224XL switch with an AT-A15/SX expansion module at each campus.
Installing the Media Converter The following sections explain how to install the media converter. The media converter can be installed on a table or in an AT-MCR12 chassis. Planning the Installation Be sure to observe the following guidelines when planning the installation of your media converter. ❑ The nodes connected to the media converter must operate at 1000 Mbps. ❑ The two nodes connected to the ports of the media converter must operate with the same duplex mode, either half- or full-duplex.
AT-MC1001 Series Installation Guide Note Many factors contribute to the ability of a fiber optic data link to transfer data efficiently. When the data rate across a fiber optic datalink reaches gigabit rates, the factors that had very minor effect at 10Base and 100Base on the ability to recover the transmitted optical data now carry a major influence. The designed/tuned optical bandwidth is a key factor.
Reviewing Safety Guidelines Please review the following safety guidelines before you begin to install the media converter. Warning Class 1 laser device. ! 6 Warning Do not stare into the laser beam. ! 7 Warning Electric Shock Hazard: To prevent electric shock, do not remove the cover. There are no user-serviceable parts inside. The unit contains hazardous voltages and should only be opened by a trained and qualified technician.
AT-MC1001 Series Installation Guide Installing the Media Converter The following procedure explains how to install the media converter in your network. If you are building a back to back installation, please review the following guidelines. See Figure 6 for an example of a back to back topology. ❑ During installation, setup, and testing of back to back media converters, make sure each media converters Link Test/MissingLink switch is in the LNK TST (UP) position.
6. Plug the AC/DC power adapter into an appropriate AC power outlet and insert the power plug into the DC receptacle located on the back of the unit. (This step does not apply if you installed the unit in an AT-MCR12 chassis.) 12 V D C Figure 7 12 V DC Connector on the Back of the Media Converter 7. Verify that the PWR LED is green. 8. Remove the dust covers from the fiber optic connectors. 9. Connect the fiber optic cables to the fiber optic ports on the media converter. 10.
AT-MC1001 Series Installation Guide Testing and Troubleshooting the Media Converter This procedure explains how to test and troubleshoot the media converter by performing a link test. A link test will determine whether each port on the media converter is successfully receiving a signal from the node connected to it. You should perform this test immediately after you have installed the media converter or whenever you are experiencing a problem with the unit. To perform a link test, perform these steps: 1.
7. If the two LNK LEDs are green but there is a communication problem between the nodes connected to the media converter (and you are not running a link test), do the following: — Verify that the nodes connected to the ports are operating at 1000 Mbps. — Verify that the nodes connected to the media converter are operating in the same duplex mode. The media converter is transparent to the duplex mode. — Verify that the Link Test/MissingLink switch on the media converter is in the M/L ON (DOWN) position.
AT-MC1001 Series Installation Guide Technical Specifications Physical Specifications Dimensions: WxDxH 10.5 cm x 9.5 cm x 2.5 cm (4.125 in x 3.75 in x 1.
Port Specifications Table 4 AT-MC1001 Series Media Converters Port Specifications Port Cable Transmitter Output Power (dBm avg.) Wavelength (nm) Minimum Receiver Sensivity (dBm avg.) 50/125 or 62.5/125 micron multimode -9.5 to -4.0 850 -17.0 10/125 micron single-mode -9.5 to -3.0 1310 -20.0 50/125 or 62.5/125 micron multimode -11.5 to -3.0 1310 -20.0 AT-MC1001/GS2 10/125 micron single-mode -3.0 to 0.0 1310 -24.0 AT-MC1001/GS3 10/125 micron single-mode -5.0 to 0.0 1550 -24.
Appendix A Translated Safety Statements Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Standards: This product meets the following standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
AT-MC1001 Series Installation Guide !9 LIGHTNING DANGER DANGER: DO NOT WORK on equipment or CABLES during periods of LIGHTNING ACTIVITY. ! 10 CAUTION: POWER CORD IS USED AS A DISCONNECTION DEVICE. TO DE-ENERGIZE EQUIPMENT, disconnect the power cord. ! 11 PLUGGABLE EQUIPMENT, the socket outlet shall be installed near the equipment and shall be easily accessible. ! 12 CAUTION: Air vents must not be blocked and must have free access to the room ambient air for cooling.
! 12 VORSICHT Die Entlüftungsöffnungen dürfen nicht versperrt sein und müssen zum Kühlen freien Zugang zur Raumluft haben. ! 13 BETRIEBSTEMPERATUR: Dieses Produkt wurde für den Betrieb in einer Umgebungstemperatur von nicht mehr als 40° C entworfen. ! 14 ALLE LÄNDER: Installation muß örtlichen und nationalen elektrischen Vorschriften entsprechen. Standarder: Dette produkt tilfredsstiller de følgende standarder.
AT-MC1001 Series Installation Guide ! 13 BETJENINGSTEMPERATUR: Dette apparat er konstrueret til en omgivende temperatur på maksimum 40 grader C. ! 14 ALLE LANDE: Installation af produktet skal ske i overensstemmelse med lokal og national lovgivning for elektriske installationer. Eisen: Dit product voldoet aan de volgende eisen. !1 RFI Emissie !2 WAARSCHUWING: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen.
Normes: ce produit est conforme aux normes de suivantes: !1 Emission d’interférences radioélectriques EN55022 Classe A !2 MISE EN GARDE : dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates. !3 Immunité EN50082 - 1 !4 Sécurité électrique EN60950, UL1950, CSA 950 !5 Laser EN60825 SÉCURITÉ !6 ATTENTION Producit laser di classe 1. !7 ATTENTION Ne pas fixer le faisceau des yeux.
AT-MC1001 Series Installation Guide Standardit: Tämä tuote on seuraavien standardien mukainen. !1 Radioaaltojen häirintä !2 VAROITUS: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin. !3 Kestävyys EN50082-1 !4 Sähköturvallisuus EN60950, UL1950, CSA 950 !5 Laser EN60825 EN55022 Luokka A TURVALLISUUS !6 VAROITUS Luokan 1 Lasertuote. !7 VARIOTUS Älä katso säteeseen.
Standard: Questo prodotto è conforme ai seguenti standard. !1 Emissione RFI (interferenza di radiofrequenza) EN55022 Classe A !2 AVVERTENZA: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati provvedimenti. !3 Immunità EN50082-1 !4 Sicurezza elettrica EN60950, UL1950, CSA 950 !5 Laser EN60825 NORME DI SICUREZZA !6 AVVERTENZA Prodotto laser di Classe 1.
AT-MC1001 Series Installation Guide Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. !1 RFI stråling !2 ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler. !3 Immunitet EN50082-1 !4 Elektrisk sikkerhet EN60950, UL1950, CSA 950 !5 Laser EN60825 EN55022 Klasse A SIKKERHET !6 ADVARSEL Laserprodukt av klasse 1. !7 ADVARSAL Stirr ikke på strålen.
Padrões: Este produto atende aos seguintes padrões. !1 Emissão de interferência de radiofrequência EN55022 Classe A !2 AVISO: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas. !3 Imunidade EN50082-1 !4 Segurança Eléctrica EN60950, UL1950, CSA 950 !5 Laser EN60825 SEGURANÇA !6 AVISO Produto laser de classe 1 !7 AVISO Não olhe fixamente para o raio.
AT-MC1001 Series Installation Guide Estándares: Este producto cumple con los siguientes estándares. !1 Emisión RFI !2 ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto. !3 Inmunidad EN50082-1 !4 Seguridad eléctrica EN60950, UL1950, CSA 950 !5 Laser EN60825 EN55022 Clase A SEGURIDAD !6 ¡ADVERTENCIA! Producto láser Clase 1.
Standarder: Denna produkt uppfyller följande standarder. !1 Radiostörning !2 VARNING: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder. !3 Immunitet EN50082-1 !4 Elsäkerhet EN60950, UL1950, CSA 950 !5 Laser EN60825 EN55022 Klass A SÄKERHET !6 VARNING! Laserprodukt av klass 1. !7 VARNING! Laserstrålning när enheten är öppen.
Appendix B AT-MC1001 Series Installation Guide Feedback Please tell us what additional information you would like to see discussed in this guide. If there are topics you would like information on that were not covered in this guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of this guide.
Appendix C Technical Support Fax Order Name _________________________________________________________________ Company ______________________________________________________________ Address _______________________________________________________________ City______________________ State/Province_______________________________ Zip/Postal Code ________________ Country_______________________________ Phone ______________________________ Fax_______________________________ Incident Summary Model number of Allied