AT-MC13 AT-MC14 Ethernet Media Converters Installation Guide PN 613-50291-00 Rev A
Copyright 2002 Allied Telesyn, Inc. 960 Stewart Drive Suite B, Sunnyvale CA 94086 USA All rights reserved. No part of this publication may be reproduced without prior written permission fro Allied Telesyn, Inc. e Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn, Inc.
Electrical Safety and Emission Compliance Statement Standards: This product meets the following standards. U.S. Federal Communications Commission Declaration Of Conformity Manufacture Name: Allied Telesyn, Inc.
Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. RFI Emission EN55022 Class B $ 1 Immunity EN55024 $ 2 Warning: This product requires shielded cables to comply with emission and immunity standards. If it is used with unshielded cables, the user may be required to take measures to correct the interference problem at their own expense.
Table of Contents Electrical Safety and Emission Compliance Statement . . . . . . . . . . . . iii Welcome to Allied Telesyn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Where to Find Web-based Guides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Contacting Allied Telesyn Technical Support . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 3 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Appendix A Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Physical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Electrical Rating . . . . . . . . . .
Welcome to Allied Telesyn This guide contains instructions on how to install the AT-MC13 and AT-MC14 Ethernet Media Converters. Where to Find Web-based Guides The Allied Telesyn web site at www.alliedtelesyn.com offers you an easy way to access the most recent documentation, software, and technical information for all of our products. For product guides, select “Support & Services” from our web site.
Welcome to Allied Telesyn Contacting Allied Telesyn Technical Support You can contact Allied Teleysn technical support online or by telephone or e-mail. Online Support You can request technical support online by accessing the Knowledge Base kb.alliedtelesyn.com. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
AT-MC13 and AT-MC14 Installation Guide E-mail Support Latin America, Mexico, Puerto Rico, Caribbean, and Virgin Islands latin_america@alliedtelesyn.com Europe support_europe@alliedtelesyn.com Returning Products Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense.
Welcome to Allied Telesyn For Sales or Corporate Information You can contact Allied Telesyn for sales or corporate information at the location below: Allied Telesyn, Inc. 19800 North Creek Parkway, Suite 200 Bothell, WA 98011 Tel: 1 (425) 487-8880 Fax: 1 (425) 489-9191 Tell Us What You Think If you have any comments or suggestions on how we might improve this or other Allied Telesyn documents, please fill out the General Enquiry Form online. This form can be accessed by selecting “Contact Us” from www.
Chapter 1 Overview The AT-MC13 and AT-MC14 media converters are designed to extend the distance of your network over large distances by interconnecting twisted pair cabling to single-mode or multimode fiber optic cabling. These media converters feature a 10Base-T twisted pair port and a 10Base-F fiber optic port. The twisted pair port has an RJ-45 connector and a maximum operating distance of 100 meters (328 feet).
Table 1 lists the maximum operating distances for the AT-MC13 and AT-MC14 media converters. Table 1 Maximum Operating Distances 10Base-F Model 10Base-T Connector Maximum Operating Distance1 Connector Maximum Operating Distance AT-MC13 ST 2 km (1.2 mi) RJ-45 100 m (328 ft) AT-MC14 SC 2 km (1.2 mi) RJ-45 100 m (328 ft) 1. Maximum operating distance may be less depending on the duplex mode of the end-nodes and the type of fiber optic cabling used with the port.
AT-MC13 and AT-MC14 Installation Guide Fiber Optic Port The 10Base-F port on the AT-MC13 and AT-MC14 media converters have either an SC or ST connector designed to operate with multimode fiber optic cabling. This port has a maximum operating distance of 2 kilometers (1.2 miles) using 62.5/125 micron multimode fiber optic cable. Status LEDs Table 2 lists the status LEDs for the AT-MC13 and AT-MC14 media converters.
NML/LNK TST Button The NML/LNK TST (Normal MissingLink/Link Test) button allows you to perform a link test on the ports on the media converter. This button also allows you to activate the MissingLink feature on the unit. The MissingLink and Link Test features are describe below. MissingLink. The MissingLink feature activates the ports on the media converter to pass the “Link” status of their connections to each other.
AT-MC13 and AT-MC14 Installation Guide Auto-negotiation Auto-negotiation determines the duplex mode of the ports. The duplex mode refers to the manner in which an end-node sends and receives data on the network. Depending on its capabilities, an end-node can operate in either halfor full-duplex mode. An end-node operating in half-duplex can either send or receive data, but not both at the same time. However, an end-node operating in full-duplex can send and receive data simultaneously.
External AC/DC Power Adapter An external AC/DC power adapter is included with the media converter for desktop operation. The power adapter supplies 12 V DC to the media converter. Allied Telesyn supplies an approved safety compliant AC power adapter for the 120 and 240 V AC versions with an unregulated output of 12 V DC at 1 A. The power requirement for these media converters is 12 V DC, 500 mA. Note The power adapter is not used if you install the media converter in an AT-MCR12 chassis.
AT-MC13 and AT-MC14 Installation Guide Back-to-Back Topology In some network configurations you may want to interconnect two media converters in what is referred to as a back-to-back topology. In this topology, the media converters not only extend the distance of your network but also convert the fiber optic cable from twisted pair to fiber optic and back again. Figure 5 illustrates two AT-8224XL switches at different campuses interconnected by two AT-MC14 media converters.
Chapter 2 Installing the Media Converter This chapter explains how to install an AT-MC13 and AT-MC14 media converter on a desktop. To install the media converter in an AT-MCR12 chassis, refer to the AT-MCR12 Installation Guide. This guide can be downloaded from our web site at www.alliedtelesyn.com. Verifying Package Contents Make sure the following items are included in your media converter package. If any item is missing or damaged, contact your sales representative for assistance.
Table 3 Twisted Pair Port Specifications Model Cable Maximum Operating Distance All models Shielded Category 3 or better 100 m (328 ft) q Refer to Table 4 and Table 5 for the fiber optic cabling specifications. Table 4 Fiber Optic Port Specifications (Full-duplex) Model Connector Cable Maximum Operating Distance1 Maximum Allowable Loss Budget AT-MC13 ST 62.5/125 micron multimode 2 km (1.2 mi) 20 dB at 850 nm AT-MC14 SC 62.5/125 micron multimode 2 km (1.2 mi) 20 dB at 850 nm 1.
AT-MC13 and AT-MC14 Installation Guide Caution Power to the hub must be sourced only from the adapter. $ 5 Warning This is a “CLASS 1 LED PRODUCT” $ 7 Warning Lightning Danger: Do not work on equipment or cables during periods of lightening activity. $ 8 Caution Do not block air vents. $ 9 Caution Operating Temperature This product is designed for a maximum ambient temperature of 40 degrees C. $ 10 Caution All Countries: Install product in accordance with local and National Electrical Codes.
Installing the Media Converter To install an AT-MC13 and AT-MC14 media converter, perform the following procedure: 1. Remove all equipment from the package and store the packaging material in a safe place. Note Do not remove the dust cover from the fiber optic port until you are ready to connect the fiber optic cable. Dust contamination can adversely impact the operating performance of the port and the media converter. 2.
AT-MC13 and AT-MC14 Installation Guide 8. Plug the AC/DC power adapter into an appropriate AC power outlet and insert the power plug into the DC receptacle located on the back of the unit. This step does not apply if you installed the unit in an AT-MCR12 chassis. 9. Verify that the Power LED is green. If the LED is OFF, refer to “Troubleshooting” on page 15 for instructions. 10. Power ON the end-nodes. 11. Verify that the LNK LEDs for the fiber optic port and the twisted pair port are green.
Chapter 3 Troubleshooting Follow the guidelines below to test and troubleshoot the installation in the event a problem occurs. If the PWR LED is OFF, do the following: q If the unit is installed on a desktop, check to be sure that the power adapter is securely connected to a power outlet and that the power adapter cable is securely connected to the back of the media converter. q If the unit is installed in an AT-MCR12 chassis, check that the unit is fully seated in the slot.
If the LNK LED for the fiber optic port is OFF, do the following: q Verify that the end-node connected to the port is ON and is operating properly. q Check that the fiber optic cable is securely connected to the fiber optic port on the media converter and on the end-node. q Check to be sure that the end-node connected to the port is operating at 10 Mbps. q Make sure that the fiber optic port on the end-node is operating in either half- or full-duplex mode.
AT-MC13 and AT-MC14 Installation Guide If the LNK LED for the fiber optic port is ON, but there is a communication problem between the end-nodes connected to the media converter (and you are not running a link test), check the following: q Check that the end-nodes connected to the ports are operating at 10 Mbps. q Check that the end-nodes are operating in the same duplex mode. These units can operate in either half- or full-duplex mode.
Appendix A Technical Specifications Physical Dimensions (W x D x H): 10.5 cm x 9.5 cm x 2.5 cm (4.1 in x 3.7 in x 1.0 in) Weight: 294 g (10.4 oz) Temperature Maximum Operating: 0° C to 40° C (32° F to 104° F) Maximum Storage: -25° C to 70° C (-13° F to 158° F) Relative Humidity: 5% to 95% non-condensing Operating Altitude: Up to 3,048 meters (10,000 feet) Electrical Rating Input Supply Voltage: 12 V DC Maximum Current: 0.
Fiber Optic Port Specifications Table 6 through Table 9 lists the specifications for the 10Base-F fiber optic port. Table 6 Fiber Optic Transmitter Model All Models Fiber Type1 MMF Fiber Optic Diameter 62.5/125 microns Optical Frequency 850 nm Launch Power (dBm)2 Maximum Average Minimum -12.0 -15.0 -18.0 1. MMF = Multimode Fiber. 2. The launch power is measured at one meter from the transmitter. Table 7 Fiber Optic Receiver Model All Models Fiber Type1 MMF Fiber Optic Diameter 62.
AT-MC13 and AT-MC14 Installation Guide Table 9 Fiber Optic Loss Specification (Benchmarks) Fiber Type1 Fiber Optic Diameter Optical Frequency Typical Loss Factor Worst Case Loss Factor MMF 62.5/125 microns 850 nm 3.00 dB/km 3.75 dB/km 200 Bandwidth 1. MMF = Multimode Fiber. Pinout Assignments Figure 6 shows the pin assignments of the RJ-45 connector.
Appendix B Translated Safety and Emission Information Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Translated Safety and Emission Information Standards: This product meets the following standards. U.S. Federal Communications Commission Declaration Of Conformity Manufacture Name: Allied Telesyn, Inc.
AT-MC13 and AT-MC14 Installation Guide $1 RFI Emission EN55022 Class B $2 Immunity EN55024 $3 Warning: This product requires shielded cables to comply with emission and immunity standards. If it is used with unshielded cables, the user may be required to take measures to correct the interference problem at their own expense. $4 Electrical Safety TUV-EN60950, UL60950 (UL/cUL) Safety $5 Power to the hub must be sourced only from the adapter.
Translated Safety and Emission Information Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. $1 Hochfrequenzstörung EN55022 Klasse B $2 Störsicherheit EN55024 $3 Achtung: Für dieses Produkt sind abgeschirmte Kabel erforderlich, damit den Richtlinien für Emission und Interferenzschutz entsprochen wird.
AT-MC13 and AT-MC14 Installation Guide $4 Elektrisk sikkerhed TUV-EN60950, UL60950 (UL/cUL) Sikkerhed $5 Strømforsyningen til apparatet må udelukkende tages fra tilpasningstransformatoren. Europe - EC Brug kun TÜV godkendt vekselstrømstransformator på 12 Vdc, 500 mA. $6 Laser/LED $7 Dette er et “PRODUKT UNDER KLASSE 1 LED” EN60825 Advarsel: Den strømførende ledning bruges til at afbryde strømmen. Skal strømmen til apparatet afbrydes, tages ledningen ud af stikket.
Translated Safety and Emission Information Waarschuwing: Het toestel wordt uitgeschakeld door de stroomkabel te ontkoppelen. Om het toestel stroomloos te maken: de stroomkabel ontkoppelen. $8 Gevaar Voor Blikseminslag Gevaar: NIET aan toestellen of KABELS WERKEN bij BLIKSEM. $9 Ventilatiegaten niet blokkeren. Sluit geen telefoonlijn aan op de signaalverbinding. $ 10 Bedrijfstemperatuur: De omgevingstemperatuur voor dit produkt mag niet meer bedragen dan 40 graden Celsius.
AT-MC13 and AT-MC14 Installation Guide Ne pas connecter une ligne téléphonique au connecteur de signaux. $ 10 Température De Fonctionnement: Ce matériel est capable de tolérer une température ambiante maximum de 40 degrés Celsius. $ 11 Pour Tous Pays: Installer le matériel conformément aux normes électriques nationales et locales. Standardit: Tämä tuote on seuraavien standardien mukainen.
Translated Safety and Emission Information Standard: Questo prodotto è conforme ai seguenti standard. $1 Emissione RFI (interferenza di radiofrequenza) EN55022 Classe B $2 Immunità EN55024 $3 Avvertenza: questo prodotto, se utilizzato con cavi schermati, è conforme alle norme sulle emissioni e sull’immunità. In caso di uso senza cavi schermati, l’utente può dover adottare a proprie spese misure correttive contro le interferenze.
AT-MC13 and AT-MC14 Installation Guide $3 Advarsel: Dette produktet må brukes med vernede kabler for å tilfredsstille emisjons- og fritakelsesstandarder. Dersom produktet brukes med uvernede kabler, må brukeren muligens rette forstyrrelsesproblemene for egen regning. $4 Elektrisk sikkerhet TUV-EN60950, UL60950 (UL/cUL) Sikkerhet $5 All strømtilførsel må komme fra adapteren. Europe - EC Benytt TÜV-godkjent AC-adapter på 12 Vdc, 500 mA (milliampere).
Translated Safety and Emission Information Europe - EC Use um adaptador de corrente alternada com saída DC de 12 Vdc, 500 mA em conformidade com as especificações da TÜV. $6 Laser/LED $7 Este é um “PRODUTO CLASSE 1 LED” EN60825 Cuidado: O cabo de alimentação é utilizado como um dispositivo de desconexão. Para deseletrificar o equipamento, desconecte o cabo de ALIMENTAÇÃO.
AT-MC13 and AT-MC14 Installation Guide $8 Peligro De Rayos Peligro: NO REALICE NINGUN TIPO DE TRABAJO O CONEXION en los equipos o en LOS CABLES durante TORMENTAS ELECTRICAS. $9 No bloquee las aberturas para ventilacion. No conectar ninguna línea telefónica al conector de señales. $ 10 Temperatura Requerida Para La Operación: Este producto está diseñado para una temperatura ambiental máxima de 40 grados C.