Extended Ethernet ® AT-MC601 AT-MC602 ◆ Installation and User’s Guide PN 613-50538-00 Rev B
Copyright © 2004 Allied Telesyn, Inc. www.alliedtelesyn.com All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn, Inc. Microsoft is a registered trademark of Microsoft Corporation, Netscape Navigator is a registered trademark of Netscape Communications Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn, Inc.
Electrical Safety and Emission Statement Standards: This product meets the following standards. U.S. Federal Communications Commission Declaration Of Conformity Manufacture Name: Allied Telesyn, Inc. (www.alliedtelesyn.com) Declares that the product: Extended Ethernet Model Numbers: AT-MC601, AT-MC602 This product complies with FCC Part 15B, Class A Limits: This device complies with part 15 of the FCC Rules.
AT-MC601 and AT-MC602 Installation and User’s Guide RFI Emission EN55022 Class A, FCC Part 15 Class A, C-TICK 1 Immunity EN55024 2 Electrical Safety EN60950, UL60950, FCC Part 68 3 Important: Appendix C contains translated safety statements for installing this equipment. When you see the , go to Appendix C for the translated safety statement in your language. Wichtig: Anhang C enthält übersetzte Sicherheitshinweise für die Installation dieses Geräts.
Contents Electrical Safety and Emission Statement ............................................................................................................................................... 3 Preface ...................................................................................................................................................................................................................... 7 How This Guide is Organized ..............................................................
AT-MC601 and AT-MC602 Installation and User’s Guide Installing the AT-MC602 Provider Unit .........................................................................................................................................................30 Cabling the Provider Unit......................................................................................................................................................................... 32 Powering On the Provider Unit .....................................
Preface This guide contains instructions on how to install and configure the AT-MC601 and AT-MC602 Extended Ethernet units. How This Guide is Organized This manual contains the following chapters and appendices: Chapter 1, Product Description, describes the features and components of the network extenders. Chapter 2, Installation, contains installation instructions for each unit. Chapter 3, Configuration, explains how to use the configuration software.
AT-MC601 and AT-MC602 Installation and User’s Guide Document Conventions This document uses the following conventions: Note Notes provide additional information. Warning Warnings inform you that performing or omitting a specific action may result in bodily injury. Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data.
AT-MC601 and AT-MC602 Installation and User’s Guide Contacting Allied Telesyn Technical Support This section provides Allied Telesyn contact information for technical support as well as sales or corporate information. Online Support E-mail and Telephone Support Returning Products You can request technical support online by accessing the Allied Telesyn Knowledge Base from the following web site: http://kb.alliedtelesyn.com.
Chapter 1 Product Description The AT-MC601, AT-MC602 Extended Ethernet products are designed to transmit data at very high speeds over unshielded pairs of copper wires using VDSL technology on your existing telephone line. Summary of Features ❑ VDSL (Very high-bit-rate Digital Subscriber) Line port ❑ PSTN (Public Switched Telephone Network) port ❑ 10/100 Mbps Ethernet port with an RJ-45 connector ❑ Auto MDI/MDI-X ❑ Auto-Negotiation for speed and duplex mode (IEEE 803.
AT-MC601 and AT-MC602 Installation and User’s Guide Overview These devices can be used in multi-dwelling units (MDU), multi-tenant buildings (MTU), and in the hospitality industry, such as airports, hotels, and convention centers. These units are sold in pairs with the AT-MC601 functioning as the subscriber and the AT-MC602 functioning as the provider.
AT-MC601 and AT-MC602 Installation and User’s Guide Location of Components Figure 2 illustrates the front panels of the AT-MC601 and AT-MC602 network extenders.
AT-MC601 and AT-MC602 Installation and User’s Guide Hardware Features The following sections describe these hardware features of the AT-MC601 and AT-MC602 network extenders: ❑ VDSL Line port ❑ PSTN port ❑ 10/100 Mbps twisted pair Ethernet port ❑ Status LEDs ❑ Management port ❑ Management cable ❑ 12V DC power supply input port ❑ External AC/DC power adapter Note The AT-MC602 unit can only be installed in an AT-MCR12 chassis.
AT-MC601 and AT-MC602 Installation and User’s Guide PSTN Port The PSTN port allows you to connect the AT-MC601 Subscriber unit to a telephone and the AT-MC602 Provider unit to the outside telco box. This port features an RJ-11 connector. Table 2 lists the RJ-11 port pinouts and their assignments.
AT-MC601 and AT-MC602 Installation and User’s Guide Auto-Negotiation.The network extenders Auto-Negotiate the speed and duplex mode of the Ethernet link, so that the link comes up in the highest performance configuration supported by both ends. Half- and Full-duplex Mode.Duplex mode refers to the way an end-node sends and receives data on the network. An end-node can operate in either half- or full-duplex mode, depending on its capabilities.
AT-MC601 and AT-MC602 Installation and User’s Guide Status LEDs The AT-MC601 and AT-MC602 network extenders feature the following status LEDs: ❑ Power ❑ Ethernet: link and activity ❑ VDSL Line: link and error Table 4 defines the LEDs for the AT-MC601 and AT-MC602 network extenders. Table 4 Status LEDs LED Color Description PWR Green Power is applied to the unit. 10/100Base-TX Port LINK Green A link has been established on the port. ACT Green Data is being received on the ports.
AT-MC601 and AT-MC602 Installation and User’s Guide MGMT Port The management port features a 8-pin DIN connector for connecting the network extenders to your laptop or PC-compatible computer for configuration using the provided management cable. Management Cable The management cable included with the AT-MC602 Provider unit features a 9-pin RS-232 connector to attach to your computer and an 8-pin DIN connector to attach to the network extender.
AT-MC601 and AT-MC602 Installation and User’s Guide AC Power Supply Input Port The network extender has a single DC power supply socket on the back panel. The unit does not have a power switch. To turn the network extender ON or OFF, you connect or disconnect the power cord. External AC/DC Power Adapter An external AC/DC power adapter is included with the network extender for desktop or wall-mount operation. The power adapter supplies 12V DC to the network extender.
AT-MC601 and AT-MC602 Installation and User’s Guide Software Features The AT-S57 software used to configure the AT-MC601 and AT-MC602 network extenders has the following features: ❑ Determine the VDSL link status ❑ Set the upstream and downstream data transfer rates ❑ Monitor the status of the VDSL parameters on both the local and remote units ❑ Monitor the status of the Ethernet parameters on both the local and remote units ❑ Link recovery Note The features listed here are further described in ”Configurat
Chapter 2 Installation This chapter contains the installation procedures for the network extenders.
AT-MC601 and AT-MC602 Installation and User’s Guide Installation Safety Precautions Please review the following safety precautions before you begin to install the network extenders. Refer to ”Translated Electrical Safety and Emission Information” on page 54 for translated safety statements in your language. Caution Power to the hub must be sourced only from the adapter. 4 Europe—EC Use TÜV licensed AC adapter of 12 V DC, min 500 mA.
AT-MC601 and AT-MC602 Installation and User’s Guide Additional Compliance Warning Statements Additional telecommunication-related compliance warning statements used with the AT-MC601 and AT-MC602 Extended Ethernet units are listed below: Warning When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electronic shock and injury to persons, including the following: 1.
AT-MC601 and AT-MC602 Installation and User’s Guide Selecting a Site for the Network Extender Observe the following requirements when choosing a site for your network extender: ❑ Make sure that the AT-MC602 Provider unit is installed in the AT-MCR12 chassis. ❑ If you plan to install the AT-MCR12 in an equipment rack, check to be sure that the rack is safely secured and that it will not tip over.
AT-MC601 and AT-MC602 Installation and User’s Guide Cables Not Included The AT-MC601 and AT-MC602 network extenders require the three cables described in Table 6 below. These cables are not included with the network extenders.
AT-MC601 and AT-MC602 Installation and User’s Guide Unpacking the Network Extender To unpack the network extender: 1. Remove all components from the shipping package and store the packaging material in a safe location. Note You must use the original shipping material if you need to return the unit to Allied Telesyn. 2. Place the network extender on a level, secure surface. 3. Make sure the following hardware components are included in your network extender package.
AT-MC601 and AT-MC602 Installation and User’s Guide Installing the AT-MC601 Subscriber Unit The AT-MC601 Subscriber unit will most likely be used as a stand-alone device, or can be used as a desktop device, or mounted onto a wall, using the keyholes on the bottom of the unit. The screws and plastic anchors used for mounting the unit are provided. To use the Subscriber unit on a desktop, perform the following procedure: 1.
AT-MC601 and AT-MC602 Installation and User’s Guide The Subscriber unit can be mounted onto a wall using the keyholes on the bottom of the unit. The screws and plastic anchors used for mounting the unit are provided. To wall-mount the Subscriber Unit, perform the following procedure: 1. If attached, remove the protective feet, data cables, and power cord from the unit. 2. Select a wall location for the device. 3. Install the screws and plastic anchors onto the wall, as shown in Figure 7.
AT-MC601 and AT-MC602 Installation and User’s Guide Cabling the Subscriber Unit To cable the Subscriber unit, perform the following steps: 1. First, connect the Ethernet cable from the Ethernet port to the Ethernet port on the computer, as shown in Figure 9. 10Base T/ 100Bas eTX LINK ACT PWR LINE AT-MC 601 VDSL MGMT EXTE NDED PSTN ETHE RNET ERR LINK Figure 9 Ethernet to Computer 2. Then, connect a telephone line cable from the PSTN port to the telephone, as shown in Figure 10.
AT-MC601 and AT-MC602 Installation and User’s Guide 3. Next, connect a telephone line cable from the VDSL Line port to the wall/interior telephone line, as shown in Figure 11, so that the Subscriber unit can communicate with the Provider unit.
AT-MC601 and AT-MC602 Installation and User’s Guide Installing the AT-MC602 Provider Unit The AT-MC602 Provider unit can only be installed in an AT-MCR12 rackmount chassis. Warning To prevent exposure to electric shock, the AT-MC602 Provider Unit must be installed in a RESTRICTED ACCESS LOCATION and performed by QUALIFIED SERVICE PERSONNEL. Note For Finland, Norway, and Sweden – When the AT-MC602 and the AT-MCR12 are used, a permanent ground conductor must be installed on the AT-MCR12 chassis.
AT-MC601 and AT-MC602 Installation and User’s Guide 2. Then, set the slider in the chassis, as shown in Figure 14.
AT-MC601 and AT-MC602 Installation and User’s Guide To cable the Provider unit, perform the following steps: 1. First, connect the Ethernet cable from the Ethernet port to the Service Provider box in your wiring closet, as shown in Figure 15. Internet Service Provider ERR LINK ACT VDSL EXTENDED ETHERNET AT-MC603 PWR 10BaseT/ 100BaseTX MGMT LINE PSTN LINK MCR12 Figure 15 Ethernet to Internet Service Provider 2.
AT-MC601 and AT-MC602 Installation and User’s Guide 3. Next, connect a telephone line cable from the VDSL Line port to the wall/interior telephone line, as shown in Figure 17, so that the Provider unit can communicate with the Subscriber unit.
AT-MC601 and AT-MC602 Installation and User’s Guide Warranty Registration When you have finished installing the network extender, register your product by completing the enclosed warranty card and mailing it to Allied Telesyn.
Chapter 3 Configuration The configuration software allows you to adjust and monitor the operating parameters of the media converter.
AT-MC601 and AT-MC602 Installation and User’s Guide Starting a Configuration Session Downloading Software Updates In order to configure and manage your AT-MC601 and AT-MC602 VDSL network extenders, you need to download a copy of the configuration software onto the computers you will use to manage the units. The ATS57 configuration software is included on the Documentation CD provided with the units. New releases of the AT-S57 configuration software are available from the Allied Telesyn Web site at www.
AT-MC601 and AT-MC602 Installation and User’s Guide Opening the Configuration Software Open the configuration software by double-clicking the “ATS57” application icon, as you would with any other software program. The ATMC60x Configurator pop-up will appear, as shown in Figure 19. Figure 19 AT-MC60x Configurator If you would like to verify that you are using the latest version of the configuration and management software, click the About button on the bottom right of the AT-MC60x Configurator pop-up.
AT-MC601 and AT-MC602 Installation and User’s Guide Configuring the Provider Unit After performing the procedure described in the previous section, ”Starting a Configuration Session” on page 36, if you are connected to the Provider unit, the AT- MC60x Configurator menu will appear. The Configurator bar at the top of the menu indicates whether or not the Provider unit has established an Ethernet link by displaying [link DOWN] or [link UP] in brackets.
AT-MC601 and AT-MC602 Installation and User’s Guide ❑ Actual (Mbps) Displays the actual data transfer rate on the line. The software automatically detects this speed. ❑ Min (Mbps) Allows you to adapt the data transfer rate by setting a minimum speed. ❑ Max (Mbps) Allows you to adapt the data transfer rate by setting a maximum speed. The maximum and minimum speeds in Mbps available in the pull-down menus are: 0.94 1.06 1.41 1.88 2.11 2.81 3.75 4.22 5.63 7.50 8.44 11.26 15.01 16.
AT-MC601 and AT-MC602 Installation and User’s Guide The Configuration Saved pop-up shown in Figure 22 will appear when the set rate or the highest possible rate has been achieved. Figure 22 Configuration Saved An unsuccessful configuration attempt may include the following status reports: Loading defaults Can’t read link status Done These negative status reports may also be accompanied by error message pop-ups. Error messages are explained in ”Troubleshooting” on page 47.
AT-MC601 and AT-MC602 Installation and User’s Guide The VDSL Status screen is displayed in Figure 23. Figure 23 VDSL Status The parameters on the VDSL Status screen are described below. These parameters are for viewing and monitoring purposes only. They cannot be changed manually. SNR of Received Signal The Signal-to-Noise Ratio on the VDSL line, measured in decibels. The SNR is a parameter of the constellation of the receive signal.
AT-MC601 and AT-MC602 Installation and User’s Guide Reduced Constellation Link A lesser QAM constellation, causing reduced line rates. If the full constellation rate cannot be achieved because the received SNR is too low, then a reduced constellation link can be established and the software can automatically configure the Subscriber unit parameters. TC Synchronized Transmission convergence is synchronized.
AT-MC601 and AT-MC602 Installation and User’s Guide The Ethernet Status screen is displayed in Figure 24. Figure 24 Ethernet Status The parameters on the Ethernet Status screen are described below. TxRx Counters The data fields in this section indicate the number and type of frames that have been transmitted and received via the Ethernet link. Collision Counters The data fields in this section indicate the number and type of collisions that have occurred on the Ethernet link.
AT-MC601 and AT-MC602 Installation and User’s Guide Stop/Start This button allows you to pause counting. When you press Stop, the counters remain at their present values. When you press Start, the counters continue adding to the values already recorded by the software. Local/Remote Select Local to view the parameters for the Provider unit. Select Remote to view the parameters for the Subscriber unit. The Remote option will only be available when an active link has been established.
AT-MC601 and AT-MC602 Installation and User’s Guide Configuring the Subscriber Unit In rare instances, you may need to use the configuration software on the Subscriber unit to attempt link recovery. If the configuration software detects a problem with the Subscriber unit while you are connected to the Provider unit, it will prompt you to use the software on the Subscriber unit by displaying a pop-up error message.
AT-MC601 and AT-MC602 Installation and User’s Guide of time, a timeout will occur. After a timeout, the default configuration parameters will be used to establish a link with the highest possible speed. The default configuration parameters start at 0.94 Mbps upstream and downstream with negotiation set from Low -> High. Select the option that corresponds to your mode choice and click the Apply button. When the mode has been set, the AT-MC60x Configurator Done message will appear, as displayed in Figure 26.
Chapter 4 Troubleshooting This chapter contains information on how to troubleshoot the AT-MC601 and AT-MC602 network extenders in the event a problem occurs. Note If after following the instructions in this chapter you are unable to resolve the problem, contact Allied Telesyn Technical Support for assistance. Refer to ”Contacting Allied Telesyn Technical Support” on page 9 for information on how to contact our Technical Support Department. LEDs Check the PWR LED on the front of the network extender.
AT-MC601 and AT-MC602 Installation and User’s Guide Verify that the ACT LED for each twisted pair port is ON. If a ACT LED is OFF, do the following: ❑ Verify that the end node connected to the port is powered ON and is operating properly. ❑ Check that the twisted pair cable is securely connected to the port on the network extender and to the port on the end node. ❑ Make sure that the twisted pair cable does not exceed 100 meters (328 feet).
AT-MC601 and AT-MC602 Installation and User’s Guide If you are unable to establish a configuration session with the network extender and receive this error message, check to be sure that the management cable is securely connected to the management port on the network extender and to the RS-232 port on the computer. Then make sure you are selecting the correct COM1 or COM2 port at the software prompt.
AT-MC601 and AT-MC602 Installation and User’s Guide This error message occurs when the Provider unit cannot achieve the link with the S or Subscriber side unit using the default speeds value. Set the Subscriber to Install Mode, as described in ”Configuring the Subscriber Unit” on page 45. ❑ “Configuration file was not found” ❑ “Syntax error in configuration file” ❑ “Configuration cannot be achieved” These last three error messages indicate a problem with the configuration software.
Appendix A Default Configuration Settings This appendix lists the AT-MC601 and AT-MC602 default settings. Setting Default Provider Parameters Monitored Speeds Upstream Max Upstream Min Downstream Max Downstream Min Flow Low to High Ethernet Port Duplex Mode Speed MDI/MDI-X Link Recovery Subscriber Unit Mode Local (Provider) .94 Mbps .94 Mbps .94 Mbps .
Appendix B Technical Specifications Physical Specifications Dimensions: (W x D x H) 109 mm x 95 mm x 25 mm (4.29 in. x 3.74 in. x 0.98 in.) Weight: .27 kg (0.6 lbs) Recommended Minimum Clearance on All Sides: 5.08 cm (2.0 in.) Environmental Specifications Operating Temperature: 0° C to 40° C (32° F to 104° F) Storage Temperature: -25° C to 70° C (-13° F to 158° F) Operating Humidity: 5% to 90% (noncondensing) Storage Humidity: 5% to 95% (noncondensing) Operating Altitude: 3,000 m (approx.
AT-MC601 and AT-MC602 Installation and User’s Guide Safety and Electromagnetic Compatibility Certifications Emission: EN55022 Class A, FCC Part 15Class A, C-TICK Immunity: EN55024 Safety: EN60950, UL60950, FCC Part 68 53
Appendix C Translated Electrical Safety and Emission Information Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
AT-MC601 and AT-MC602 Installation and User’s Guide Standards: This product meets the following safety standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
AT-MC601 and AT-MC602 Installation and User’s Guide Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. 1 Hochfrequenzstörung EN55022 Klasse A, FCC Part 15 Klasse A, C-TICK 2 Störsicherheit EN55024 3 Elektrische Sicherheit EN60950, UL60950, FCC Part 68 Sicherheit 4 Der Buchse darf nur aus dem Adpater Strom zugeführt werden. Europe—EC Gebrauchen Sie einen von TÜV zugelassenen Wechselstromadapter für Gleichstrom 12 Vdc, 500 mA.
AT-MC601 and AT-MC602 Installation and User’s Guide Standarder: Dette produkt tilfredsstiller de følgende standarder. 1 Radiofrekvens forstyrrelsesemissionEN55022 Klasse A, FCC Part 15 Klasse A, C-TICK 2 Immunitet EN55024 3 Elektrisk sikkerhed EN60950, UL60950, FCC Part 68 Sikkerhed 4 Strømforsyningen til apparatet må udelukkende tages fra tilpasningstransformatoren. Europe - EC Brug kun TÜV godkendt vekselstrømstransformator på 12 Vdc, 500 mA.
AT-MC601 and AT-MC602 Installation and User’s Guide Eisen: Dit product voldoet aan de volgende eisen. 1 RFI Emissie EN55022 Klasse A, FCC Part 15 Klasse A, C-TICK 2 Immuniteit EN55024 3 Electrische Veiligheid EN60950, UL60950, FCC Part 68 Veiligheid 4 Stroom mag alleen via de adapter naar het apparaat toegevoerd worden. Europe - EC Gebruik een door TÜV gekeurde wisselstroomadapter van 12 Vdc, 500 mA. 5 Waarschuwing: Het toestel wordt uitgeschakeld door de stroomkabel te ontkoppelen.
AT-MC601 and AT-MC602 Installation and User’s Guide Normes: ce produit est conforme aux normes de suivantes. 1 Eemission d’interférences radioélectriques EN55022 Classe A, FCC Part 15 Classe A, C-TICK 2 Immunité EN55024 3 Sécurité électrique EN60950, UL60950, FCC Part 68 Sécurité 4 L’alimentation du concentrateur doit être uniquement fournie par l’adaptateur. Europe - EC Utiliser un adaptateur secteur conforme TÜV de 12 V dc, 500 mA en courant continu.
AT-MC601 and AT-MC602 Installation and User’s Guide Standardit: Tämä tuote on seuraavien standardien mukainen. 1 Radioaaltojen häirintä EN55022 Luokka A, FCC Part 15 Luokka A, C-TICK 2 Kestävyys EN55024 3 Sähköturvallisuus EN60950, UL60950, FCC Part 68 Turvallisuus 4 Tähtipisteeseen (hub) syötettävän virran pitää tulla ainoastaan sovittimesta. Europe - EC Käytä TÜV-lisenssillä valmistettua verkkosovitinta, jonka tasajännitteen nimellisarvot ovat 12 Vdc, 500 mA (milliampeeria).
AT-MC601 and AT-MC602 Installation and User’s Guide Standard: Questo prodotto è conforme ai seguenti standard. 1 Emissione RFI (interferenza di radiofrequenza) EN55022 Classe A, FCC Part 15 Classe A, C-TICK 2 Immunità EN55024 3 Sicurezza elettrica EN60950, UL60950, FCC Part 68 Norme Di Sicurezza 4 Questo dispositivo deve essere alimentato solo mediante l’adattatore. Europe - EC Utilizzare l’adattatore per c.a. da 12 Vdc, 500 mA conforme alla normativa TÜV.
AT-MC601 and AT-MC602 Installation and User’s Guide Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. 1 RFI stråling EN55022 Klasse A, FCC Part 15 Klasse A, C-TICK 2 Immunittet EN55024 3 Elektrisk sikkerhet EN60950, UL60950, FCC Part 68 Sikkerhet 4 All strømtilførsel må komme fra adapteren. Europe - EC Benytt TÜV-godkjent AC-adapter på 12 Vdc, 500 mA (milliampere). 5 Forsiktig: Strømledningen brukes til å frakoble utstyret.
AT-MC601 and AT-MC602 Installation and User’s Guide Padrões: Este produto atende aos seguintes padrões. 1 Emissão de interferência de radiofrequência EN55022 Classe A, FCC Part 15 Classe A, C-TICK 2 Imunidade EN55024 3 Segurança eléctrica EN60950, UL60950, FCC Part 68 Segurança 4 Use somente o adaptador fornecido para alimentação elétrica do hub. Europe - EC Use um adaptador de corrente alternada com saída DC de 12 Vdc, 500 mA em conformidade com as especificações da TÜV.
AT-MC601 and AT-MC602 Installation and User’s Guide Estándares: Este producto cumple con los siguientes estándares. 1 Emisión RFI EN55022 Clase A, FCC Part 15 Clase A, C-TICK 2 Inmunidad EN55024 3 Seguridad eléctrica EN60950, UL60950, FCC Part 68 Seguridad 4 La energía para el dispositivo central o “hub” debe provenir únicamente del adaptador. Europe - EC Utilizar un adaptador de corriente alterna autorizado TÜV de 12 Vdc, 500 mA.
AT-MC601 and AT-MC602 Installation and User’s Guide Standarder: Denna produkt uppfyller följande standarder. 1 Radiostörning EN55022 Klass A, FCC Part 15 Klass A, C-TICK 2 Immunitet EN55024 3 Elsäkerhet EN60950, UL60950, FCC Part 68 Säkerhet 4 Endast anslutningsenheten får vara kraftkälla till centralen. Europe - EC Använd en växelströmsanslutningsenhet licensierad av TÜV. Likström 12 Vdc, 500 mA.