Media Converter Chassis AT-MCR1 Installation Guide 613-000687 Rev B
Copyright © 2007 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Allied Telesis is a trademark of Allied Telesis, Inc. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesis, Inc.
Electrical Safety and Emission Compliance Statement Standards: This product meets the following standards. U.S. Federal Communications Commission Declaration of Conformity Manufacturer Name: Declares that the product: Model Numbers: Allied Telesis, Inc. Media Converter Chassis AT-MCR1 This product complies with FCC Part 15B, Class B Limits: This device complies with part 15 of the FCC Rules.
Industry Canada This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. RFI Emissions FCC Part 15 Class B Immunity EN55024 Electrical Safety EN60950 (TUV), UL 60950-1 (cULus), CSA C22.
Contents Preface .........................................................................................7 Safety Symbols Used in this Document ........................................8 Where to Find Web-based Guides ................................................9 Contacting Allied Telesis .............................................................10 Online Support ....................................................................10 Email and Telephone Support........................................
Contents Temperature ................................................................................45 Electrical Rating (for AC version only).........................................45 Safety and Electromagnetic Emissions Certifications .................46 Compliance Standards ................................................................
Preface This guide contains instructions on how to install an AT-MCR1 Media Converter Chassis.
Preface Safety Symbols Used in this Document This document uses the safety symbols in Table 1. Table 1. Safety Symbols Symbol 8 Meaning Description Caution Performing or omitting a specific action may result in equipment damage or loss of data Warning Performing or omitting a specific action may result in electrical shock.
AT-MCR1 Media Converter Chassis Installation Guide Where to Find Web-based Guides The installation and user guides for all Allied Telesis products are available in portable document format (PDF) on our web site at www.alliedtelesis.com. You can view the documents online or download them onto a local workstation or server.
Preface Contacting Allied Telesis This section provides Allied Telesis contact information for technical support as well as sales or corporate information. Online Support You can request technical support online by accessing the Allied Telesis Knowledge Base: www.alliedtelesis.com/kb. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
AT-MCR1 Media Converter Chassis Installation Guide tab. Sales or Corporate Information You can contact Allied Telesis for sales or corporate information on our web site: www.alliedtelesis.com. To find the contact information for your country, select Contact Us -> Worldwide Contacts.
Preface 12
Chapter 1 Overview The AT-MCR1, shown in Figure 1, is a chassis with an internal power supply designed to house one Allied Telesis media converter. The AT-MCR1 chassis provides convenient installation options: on a desktop, mounted under a table, placed on the wall, or installed in an industry standard 19” or 23” rack. AT-MCR1 PWR 1046 Figure 1. AT-MCR1 Media Converter Chassis The AT-MCR1 chassis includes a mounting rail (750-10857-00), as shown in Figure 2, for installing a media converter.
Chapter 1: Overview Key Features The AT-MCR1 chassis has the following features: LED for unit status One slot for an ATI standard media converter Internal AC/DC power supply Desktop, wall, under table, or rack mount installation Status LEDs Refer to Table 2 for a description of the chassis LED. Table 2. LED LEDs PWR 14 Color Description Green Power on the AT-MCR1 chassis is ON. OFF Power on AT-MCR1 chassis is OFF.
Chapter 2 Installation This chapter contains the following sections: “Reviewing Safety Precautions” on page 16 “Verifying the Package Contents” on page 20 “Selecting a Site” on page 21 “Installing a Media Converter in the Chassis” on page 22 “Installing the Chassis On a Table or Desktop (AC Models Only)” on page 25 “Installing the Chassis Under a Table (AC Models Only)” on page 26 “Mounting the Chassis on the Wall” on page 29 “Installing the Chassis in a Rack” on page 32
Chapter 2: Installation Reviewing Safety Precautions Review the following safety precautions before you begin to install the AT-MCR1 chassis. Note The indicates that a translation of the safety statement is available in a PDF document titled “Translated Safety Statements” on the Allied Telesis website at www.alliedtelesis.com. Warning: Class 1 Laser product. L 1 Warning: Do not work on equipment or cables during periods of lightning activity. E2 Warning: Power cord is used as a disconnection device.
AT-MCR1 Media Converter Chassis Installation Guide Caution: Air vents must not be blocked and must have free access to the room ambient air for cooling. E6 Warning: Operating Temperature. This product is designed for a maximum ambient temperature of 40° degrees C. E7 All Countries: Install product in accordance with local and National Electrical Codes. E8 Warning: As a safety precaution, install a circuit breaker with a minimum value of 16 Amps between the equipment and the DC power source.
Chapter 2: Installation Warning: Check to see if there are any exposed copper strands coming from the installed wires. When this installation is done correctly there should be no exposed copper wire strands extending from the terminal block. Any exposed wiring can conduct harmful levels of electricity to persons touching the wires. E12 This system will work with a positive grounded or negative grounded DC system.
AT-MCR1 Media Converter Chassis Installation Guide Warning: Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuits (e.g., use of power strips).
Chapter 2: Installation Verifying the Package Contents Make sure the following items are included in your package. If any item is missing or damaged, contact your Allied Telesis sales representative for assistance. One AT-MCR1 Media Converter Chassis with a mounting rail installed Four protective rubber feet (for desktop use only) Two mounting brackets Eight bracket-mounting screws (M3X6) Four wall-mount plastic anchors (No. 6-10, 7/8 inch) Four self-tapping screws (3.
AT-MCR1 Media Converter Chassis Installation Guide Selecting a Site Be sure to observe the following requirements when choosing a site for your chassis. Make sure you are placing the chassis in a dust-free and moisture-free environment. Do not block the ventilation openings on the unit. Allow at least 10 centimeters (4 inches) of space at the front and back of the unit for ventilation. Make sure that the chassis’ power is accessible and cables can be connected easily.
Chapter 2: Installation Installing a Media Converter in the Chassis To install a media converter in the AT-MCR1 chassis, perform the following procedure: 1. Remove all components from the shipping packages. Note Store the packaging material in a safe place. You must use the original shipping material if you need to return the unit to Allied Telesis. 2. Loosen the captive screw on the mounting rail and remove it from the chassis, as shown in Figure 3. -M AT CR 1 PW R 1048 Figure 3.
AT-MCR1 Media Converter Chassis Installation Guide 3. Align the mounting rail with the media converter, placing the two pins into the front and rear air vents, as shown in Figure 4. se-T Ba 1000 R PW LINK T AC se Ba 1000 ML L SM DE MO 1 T SS DUC CLAPRO ER LAS LINK T AC B GIG IT AB H ET N ER ET ME DIA TO AU LT NV CO TE ER I/M MD X DI- R 8/G 00 C1 -M AT 1049 Figure 4. Aligning the Mounting Rail with the Media Converter 4.
Chapter 2: Installation 5. Press gently on the media converter to seat the power plug into the chassis. 6. Tighten the captive screw on the mounting rail to secure the media converter in the chassis, as shown in Figure 6 -M AT 1000 Ba CR 1 se-T PW R R PW K LIN T AC 1000 Ba se E MOD S 1 UCT CLAS PROD LASER K LIN T AC MC AT- 0 10 8/G B GIG AB IT ET RN HE ET MED IA NV CO ML L SM LT TE ER TO AU /M MDI DI-X R 1278 Figure 6.
AT-MCR1 Media Converter Chassis Installation Guide Installing the Chassis On a Table or Desktop (AC Models Only) To install the chassis on a table or desktop, perform the following procedure: 1. Turn the AT-MCR1 chassis over. 2. Attach the four protective rubber feet to the bottom of the chassis, as shown in Figure 7. AT-MC1008/GB GIGABIT ETHERNET MEDIA CONVERTER LT ACT SML LINK CLASS 1 LASER PRODUCT MODE 1000Base ML AUTO MDI/MDI-X ACT LINK PWR PWR 1000Base-T AT-MCR1 1051 Figure 7.
Chapter 2: Installation Installing the Chassis Under a Table (AC Models Only) The AT-MCR1 chassis can be mounted under a table using the mounting brackets shipped with the chassis. Note Make sure that the under-table location provides easy access for installing the twisted pair, fiber optic, and power cables to and from the chassis. Note Before you install the AT-MCR1 chassis under a table, install the cables.
AT-MCR1 Media Converter Chassis Installation Guide 3. Attach one mounting bracket (provided) to each side of the chassis using the bracket mounting screws (provided), as shown in Figure 8. 1 CR -M AT 100 0B ase -T PW R R PW K LIN T AC 100 0B ase ML L SM DE MO TO AU LT DI-X I/M MD R DIA ET AT- NV CO TE ER HE K LIN T AC 08 10 MC ME RN 1 CT CLASS PRODU LASER BIT ET GA /GB GI 1052 Figure 8. Attaching Brackets for Under-Table Installation 4.
Chapter 2: Installation 5. Make sure that the chassis is securely mounted under the table. 6. Power the chassis on following the instructions in “Powering On an AC-Powered Chassis” on page 34.
AT-MCR1 Media Converter Chassis Installation Guide Mounting the Chassis on the Wall The chassis can be mounted vertically on a wall using the mounting brackets that come with the unit. To mount an AT-MCR1 chassis on the wall, perform the following procedure: 1. If attached, remove the rubber feet and power cord from the chassis. 2. Select a wall location for the chassis and mark two hole locations for the wall-mounting screws or plastic wall anchors (for wall-mounting onto a concrete wall).
Chapter 2: Installation 3. Turn the chassis over and attach a mounting bracket (provided) to each side of the chassis using the bracket mounting screws (provided), as shown in Figure 10. 1 CR -M AT 100 0B ase -T PW R R PW K LIN T AC 100 0B ase DE MO ML L SM LT TO AU DI-X I/M MD R DIA ET M AT- TE ER HE K LIN T AC 08 C10 NV CO ME RN 1 CT CLASS PRODU LASER BIT ET GA /GB GI 1052 Figure 10. Attaching the Brackets for Wall Mounting 4.
AT-MCR1 Media Converter Chassis Installation Guide 5. Make sure that the chassis is securely mounted onto the wall. 6. Install the cables. For cabling instructions, refer to the installation guide that is shipped with the Allied Telesis media converter. 7.
Chapter 2: Installation Installing the Chassis in a Rack You can mount the chassis in an industry-standard 19” or 23” rack. To install the chassis in a rack, perform the following procedure: 1. If attached, remove the rubber feet, data cables, and power cord from the chassis. 2. Attach one mounting bracket (provided) to the right side of the AT-MCR1 chassis using the bracket mounting screws (provided), as shown in Figure 12.
AT-MCR1 Media Converter Chassis Installation Guide 3. Mount the AT-MCR1 chassis on a 19” or 23” rack using the rackmounting screws (not provided), as shown in Figure 13. CLASS LASER 1 PROD UCT LIN K AC T ATMC 100 1000 Base 8/G B GIGA BIT MOD E ET HE ML RN ET MED IA SM L LT CO NV ATMC R1 1000 Base -T PW R LIN K AC T ER TE R AU TO MDI /MDI PW R -X 1056 Figure 13. Mounting the Chassis in a Rack 4. Make sure that the chassis is securely mounted in the rack. 5. Install the cables.
Chapter 2: Installation Powering On an AC-Powered Chassis To apply power to an AC-powered AT-MCR1 chassis, perform the following procedure: 1. Install the retaining clip on the chassis, as shown in Figure 14. 100 -24 0VA C~ 1022 Figure 14. Installing the Power Cord Retaining Clip 2. Position the power cord retaining clip in the up position, as shown in Figure 15. 100 -24 0VA C~ 1023 Figure 15.
AT-MCR1 Media Converter Chassis Installation Guide 3. Plug the power cord into the power connector on the back of the chassis, as shown in Figure 16. 100 -24 0VA C~ 1057 Figure 16. Plugging the Power Cord into the Chassis 4. Secure the cord by lowering the power cord retaining clip, as shown in Figure 17. 100 -24 0VA C~ 1024 Figure 17. Securing the Power Cord with the Retaining Clip 5. Plug the other end of the power cord into a wall outlet.
Chapter 2: Installation Pluggable Equipment. The socket outlet shall be installed near the equipment and shall be easily accessible. E5 6. Verify that the PWR LED in the front of the chassis is green. If the PWR LED is OFF, refer to Chapter 3, ”Troubleshooting” on page 43 for instructions. The chassis runs a series of self-diagnostic tests, which take a few seconds to perform. After the self tests are complete, the chassis is ready for normal network operations.
AT-MCR1 Media Converter Chassis Installation Guide Wiring and Powering On a DC-Powered Chassis To wire and power on a DC-powered chassis, perform the following procedure: Warning As a safety precaution, install a circuit breaker with a minimum value of 15 Amps between the equipment and the DC power source. Always connect the wiring to the LAN equipment first before you connect the wiring to the circuit breaker. Do not work with HOT feeds to avoid the danger of physical injury from electrical shock.
Chapter 2: Installation A tray cable is required to connect the power source if the chassis is powered by centralized DC power. The tray cable must be an UL listed Type TC tray cable and rated at 600 V and 90 degree C, with three conductors, minimum 14 AWG. E24 1. On the back panel of the chassis is a DC terminal block, starting from the left side of the terminal block, identify the positive, frame ground, and negative terminals, using the symbols above the terminal block, as shown in Figure 18.
AT-MCR1 Media Converter Chassis Installation Guide Warning Do not strip more than the recommended amount of wire. Stripping more than the recommended amount can create a safety hazard by leaving exposed wire on the terminal block after installation. E10 3. Connect the frame ground wire to the terminal marked with the ground symbol by inserting the wire into the terminal and tightening the connection with a flathead screwdriver, as shown in Figure 20 on page 39.
Chapter 2: Installation 5. Connect the negative feed wire to the terminal block marked (-). Warning Check to see if there are any exposed copper strands coming from the installed wires. When this installation is done correctly there should be no exposed copper wire strands extending from the terminal block. Any exposed wiring can conduct harmful levels of electricity to persons touching the wires. E12 6.
AT-MCR1 Media Converter Chassis Installation Guide For cabling instructions, refer to the installation guide that is shipped with the Allied Telesis media converter.
Chapter 2: Installation Warranty Registration When you have finished installing the product, register your product by completing the enclosed warranty card and sending it in. You can also fill out the registration online by selecting “Warranties” under “Support & Services” from www.alliedtelesis.com.
Chapter 3 Troubleshooting Follow the guidelines below to test and troubleshoot the installation in the event a problem occurs. If the PWR LED is OFF, do the following: Check to be sure that the power adapter is securely connected to the power source and to the DC connector on the front of the AT-MCR1 chassis. Check to be sure that the power outlet has power by connecting another device to it. Try replacing the power adapter with another power adapter.
Chapter 3: Troubleshooting 44
Appendix A Technical Specifications Physical Dimensions: WxDxH 130 mm x 166 mm x 44 mm (5.118 in x 6.535 in x 1.732 in) Weight: .27 kg (0.
Appendix A: Technical Specifications Safety and Electromagnetic Emissions Certifications RFI Emissions FCC Part 15 Class B Immunity EN55024 Electrical Safety EN60950 (TUV), CE Compliance Standards RoHS Compliant 46