Copyright 2000 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale, CA 94085 USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. CentreCom is a registered trademark of Allied Telesyn International, Corp. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn International, Corp.
Electrical Safety and Emission Statement Standards: This product meets the following standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Table of Contents Table of Contents ................................................................................................................................................................................................. 5 Preface ...................................................................................................................................................................................................................... 7 Audience .............................................
Table of Contents Chapter 2 Installation ........................................................................................................................................................................................................... 29 Verifying the Package Contents ..................................................................................................................................................................... 30 Reviewing Safety Precautions ..................................
Preface This guide contains instructions on how to install the AT-9006T, AT-9006SX/SC, and AT-9006LX/SC Gigabit Ethernet Switches. Audience This guide is intended for network administrators who are responsible for installing and managing the switches. Network administrators should be familiar with Ethernet switches, Ethernet and Fast Ethernet technology, bridging, and the Spanning Tree Protocol (STP).
Preface Document Conventions This document uses several conventions that you should become familiar with before you begin to install the product. Note Notes provide additional information. Warning Warnings inform you that performing or omitting a specific action may result in bodily injury. Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data.
AT-9006 Series Installation Guide Where to Find Web-based Guides The Allied Telesyn web site at www.alliedtelesyn.com offers you an easy way to access the most recent documentation and technical information for all Allied Telesyn International products. All web-based documentation for this product and other Allied Telesyn products can be downloaded from the web site in PDF format. You will need the following manual in addition to this guide in order to manage the Gigabit Ethernet switch.
Preface Contacting Allied Telesyn There are several ways that you can contact Allied Telesyn technical support: online, telephone, fax and e-mail. Online Support Telephone and Fax Support E-mail Support You can request technical support online by filling out the Online Technical Support Form at www.alliedtelesyn.com/forms/support.htm.
AT-9006 Series Installation Guide Returning Products Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense.
Preface FTP Server If you need management software for an Allied Telesyn device and you know the name of the management software file, you can download the software by connecting directly to our FTP server at ftp://gateway.centre.com. At login, enter ‘anonymous’. Enter your e-mail address for the password as requested by the server at login.
AT-9006 Series Installation Guide For Sales or Corporate Information Allied Telesyn International, Corp. 19800 North Creek Parkway, Suite 200 Bothell, WA 98011 Tel: 1 (425) 487-8880 Fax: 1 (425) 489-9191 Allied Telesyn International, Corp.
Preface Tell Us What You Think If you have any comments or suggestions on how we might improve this or other Allied Telesyn documents, please fill out the Send Us Feedback Form at www.alliedtelesyn.com/forms/feedback.htm.
Chapter 1 Product Description The AT-9006 Series Gigabit Ethernet Switches allow you to build a flexible network topology suited to the demands of your network environment. The switches provide non-blocking architecture and fullwire speed performance on all ports. They can serve as high speed workgroup switches with dedicated links to workstations, printers, and servers, or as links to additional hubs and switches to form a high speed infrastructure for large networks.
Product Description Summary of Features # Six 100Base-T/1000Base-TX ports with RJ-45 connectors (AT-9006T) # Six 1000Base-SX ports with dual SC connectors (AT-9006SX/SC) # Six 1000Base-LX ports with dual SC connectors (AT-9006LX/SC) # 12 K MAC address table with automatic aging # 2 MB SGRAM packet memory per port # 3 MB flash memory for software upgrades # 1.5u high chassis # Port trunking # Port mirroring # BOOTP and DHCP support # AT-S26 management software # Omega management interface # IEEE 803.
AT-9006 Series Installation Guide Switch Models Table 1 lists the switch models. Table 1 AT-9006 Series Switches Model1 Number of Ports Type of Connector Maximum Distance AT-9006T 6 100Base-T / 1000Base-TX RJ-45 100 m (328 ft) AT-9006SX/SC 6 1000Base-SX Dual SC 550 m (1804 ft)2 AT-9006LX/SC 6 1000Base-LX Dual SC 10 km (6.25 mi)3 Type of Port 1. All models include two expansion slots. 2. Assumes 50/125 micron fiber optic cable with a rating of 500 MHz/Km. 3.
Product Description Features and Components Figure 1 illustrates the front panel components.
AT-9006 Series Installation Guide Six Fiber Optic 1000 Mbps Ports (AT-9006SX/SC and AT-9006LX/SC) The AT-9006SX/SC and AT-9006LX/SC Gigabit Ethernet Switches feature six fiber optic ports with dual SC connectors. The ports operate at 1000 Mbps in full-duplex mode. (The ports can be configured as half-duplex, but since all 1000 Mbps network devices operate at full-duplex, there should be no reason to set one of the ports to half-duplex.
Product Description Table 3 describes the port LEDs. Table 3 Port LEDs LED State Description Link/Activity Solid Green This indicates a 1000 Mbps link has been established between the port and the end node. Flashing Green This indicates 1000 Mbps activity on the port. Solid Amber This indicates a 100 Mbps link has been established between the port and the end node (AT-9006T only). Flashing Amber This indicates 100 Mbps activity on the port (AT-9006T only).
AT-9006 Series Installation Guide Expansion Slots The switch features two expansion slots on the front panel. You can use the slots to install optional expansion modules which you can use to extend the distance of your network, build high-speed backbone networks, and connect additional nodes to the network, such as highspeed servers.
Product Description AT-S26 Management Software and Omega Management Interface Included with the switch is the AT-S26 management software. You use this pre-installed software to manage the switch’s operating parameters, view port and switch status information, and monitor performance statistics. Included with the management software is the Omega management interface.
AT-9006 Series Installation Guide SNMP Session You can also manage the switch using an SNMP management program, such as HP Openview. This method requires that you load the AT-9006 Series Switch MIBs onto the workstation from which you intend to manage the switch and that you compile the MIBs with a MIB complier. The MIBs for the AT-9006 Series Gigabit Ethernet Switch are available from the Allied Telesyn web site.
Product Description STP addresses this problem by ensuring that there is only one path between the end nodes. Where multiple paths exist, STP places the extra paths in a redundant or standby mode, leaving only one main active path. The redundant paths can be activated by STP if the main path goes down. So not only does STP guard against multiple links between end nodes, but it also activates backup redundant paths in case a main link fails.
AT-9006 Series Installation Guide The ratio used by the switch in handling packets in the two queues is adjustable. There are eight possible settings. The settings allow you to adjust the level of importance given to tagged packets in the high priority queue as compared to packets in the normal priority queue. The lowest setting is 1 to 1, meaning that the switch will treat packets in both the high and normal queues the same.
Product Description # With VLAN tagging, the ability to group workstations into logical work groups is more versatile. Network servers or other network resources can be shared without loss of data isolation or security. # With VLAN tagging, one port on a switch can be configured to be an uplink to another 802.1Q-compatible switch. This one port can be configured to carry traffic from all VLANs configured on the switch.
AT-9006 Series Installation Guide Network Topologies Figure 3 shows a network topology that uses an AT-9006SX/SC switch and an AT-9006LX/SC switch to form a Gigabit Ethernet infrastructure.
Product Description Where to Go Next Proceed to Chapter 2 for details on how to install the switch.
Chapter 2 Installation This chapter contains the installation procedures for the switch.
Installation Verifying the Package Contents Make sure the following hardware components are included in your switch package. If any of the items are missing or damaged, contact your Allied Telesyn sales representative.
AT-9006 Series Installation Guide Reviewing Safety Precautions Please review the following safety precautions before you begin to install the switch. Refer to Appendix C for translated safety statements in your language. Laser Class 1 laser product. " 6 Laser Do not stare into the laser beam. " 7 Warning Electric Shock Hazard: To prevent electric shock, do not remove the cover. There are no user-serviceable parts inside.
Installation Selecting a Site for the Switch Be sure to observe the following requirements when choosing a site for your switch: # Make sure that the switch’s power is accessible and cables can be easily connected. # Air flow around the switch and through its vents on the side and rear must not be restricted. # If you are installing the switch on a desk, make sure it is placed on a level, secure desktop. # Do not place objects on top of the switch. # Do not expose the switch to moisture or water.
AT-9006 Series Installation Guide Planning the Installation Table 4 contains the cabling specifications for the switches. Table 4 Media Types and Distances Mhz/Km Rating Maximum Distance Category 5 and Enhanced Category 5 100-ohm UTP or STP1 - 100 m (328ft) 50/125 micron multimode fiber 400 500 m (1,640 ft) 50/125 micron multimode fiber 500 550 m (1,804 ft) 62.5/125 micron multimode fiber 160 220 m (722 ft) 62.
Installation Installing the Switch on a Desktop The switch can be installed in a standard 19-inch rack or on a table or desktop. To install the switch in a rack, go to the section Installing the Switch in a Rack on page 36. To install the switch as a table or desktop, perform the following steps: 1. Remove all components from the shipping package and store the packaging material in a safe location. 2. Locate a level, secure surface for the switch. 3.
AT-9006 Series Installation Guide As power is applied to the switch, the Fault LED (shown in Figure 5) flashes as the switch runs a series of internal self tests. After the switch has finished running its self tests, the Fault LED will stop flashing and will remain OFF. Refer to the section System and Port LEDs on page 19 for information on all of the system and port LEDs. RS-232 TERMINAL PORT STATUS Fault LED FAULT RPS PWR RESET Figure 5 Fault LED 6.
Installation Installing the Switch in a Rack To install the switch in a standard 19-inch rack, perform the following steps: 1. Remove all components from the shipping package and store the packaging material in a safe location. 2. Place the unit on a level, secure surface. 3. Using a flat-head screwdriver, remove the snap-on plastic feet from the bottom of the switch, as shown in Figure 6. Figure 6 Removing the Feet 4.
AT-9006 Series Installation Guide 6. Mount the switch in the rack using standard screws (not provided). Caution Air vents must not be blocked and must have free access to the room ambient air for cooling. " 13 7. If you purchased a redundant power supply (RPS) unit for the switch, connect the RPS unit to the R.P.S. Input connector (Figure 4) on the rear of the switch by following the directions included with the RPS stem.
Installation Installing an Expansion Module This section contains instructions for installing an optional expansion module in the switch. Note For a list of the Allied Telesyn expansion modules supported by your AT-9006 Gigabit Ethernet Switch and the AT-S26 management software, refer to the Preface in the AT-S26 Management Software User’s Guide. Note For information on cabling specifications for the expansion module, refer to the Quick Install Guide that is included with the module.
AT-9006 Series Installation Guide A B Figure 8 Removing the Blank Panel If you are installing only one expansion module in the switch, you should install the module in slot A. While the module will work in slot B with slot A empty, the port numbering assignments will change if you later install a module in slot A. This could affect the VLAN memberships on the switch and this could require you to adjust your VLAN configurations.
Installation 4. Slide the expansion module into the empty slot making sure the board is aligned properly with the card guides. Refer to Figure 9. Card Guide A AT-A15 ACTIVITY B LINK FULL DUP 1000BASE -X COL HALF DUP Board Figure 9 Installing an Expansion Module 5. Secure the expansion module to the switch by tightening the captive screws. 6. Apply power to the switch by re-attaching the power cord to the switch. Verify that the Power LED is green. 7.
AT-9006 Series Installation Guide Starting a Local Omega Management Session This procedure explains how to establish a local Omega management session with the switch. You must establish a local management session if you have just installed the switch in a TCP/IP environment. You must assign the switch an IP address and subnet mask or configure the switch to obtain its IP parameters from a BOOPT or DHCP server.
Installation Warranty Registration When you have finished installing the switch, you should register your product by completing the enclosed warranty card and sending it in, or by visiting our web site at www.alliedtelesyn.com/forms/warranty.htm and completing the on-line registration.
AT-9006 Series Installation Guide Where to Go Next Now that the switch is operational, you are ready to configure and monitor the unit as explained in the AT-S26 Management Software User’s Guide, which is available from Allied Telesyn’s web site at www.alliedtelesyn.com.
Chapter 3 Troubleshooting This chapter provides information on how to detect and resolve problems with your switch.
Troubleshooting At the First Sign of a Problem Perform the following tasks when you first become aware of a problem with the switch: # Make sure the power cord is securely connected and the power voltage is not fluctuating. # Check the data cables for secure connections and make sure the device at the other end of a connection is operational. # Use Omega to read statistics and run diagnostics.
AT-9006 Series Installation Guide How the Switch Reports Problems The switch detects and processes errors as follows: # The LEDs indicate problems with the ports and power. For information on the LEDs, refer to the section System and Port LEDs on page 19. # In a TCP/IP environment, if you have configured the software correctly, the management software triggers an SNMP trap message. As a result, the software then sends traps to alert the network manager when a trigger occurs.
Troubleshooting Common Problems This section lists common possible sources of errors and the actions required to correct them. Link /Activity LED on Any Port is OFF This can indicate: # A loose data cable. # The device at the other end of the connection is powered OFF. # The port’s selected transmission mode does not match that of the attached device. Perform the following steps in sequence; you need not proceed to the next step if the problem is resolved: 1. Make sure the data cables are secure. 2.
AT-9006 Series Installation Guide Fault LED is ON This might indicate problems with the AT-S26 management software, such as: # An unsuccessful software download # A failure of the power-on diagnostics Perform the following steps in sequence; you need not proceed to the next step if the problem is resolved: 1. Reset the switch either by: — Pressing the RESET button on the front panel, or — Selecting Administration>Reset and restart the system from Omega, if you can. 2.
Troubleshooting Calling Technical Support When contacting Allied Telesyn for support on any of its products, you will need to provide Technical Support with the following information: # Model and serial number # Software version number # Description of the problem Refer to Contacting Allied Telesyn on page 10 or Allied Telesyn’s web site at www.alliedtelesyn.com for a list of worldwide locations.
Appendix A Technical Specifications Physical Specifications Dimensions Weight Required Ventilation on All Sides 6.48 cm x 42.93 cm x 35.60 cm (2.55 in x 16.9 in x 14.0 in) (H x W x D) AT-9006T: 7.14 (15.70 lbs) AT-9006SX/SC and AT-9006LX/SC: 6.12 kg (13.60 lbs) 19 cm (7.
Technical Specifications Environmental Specifications Operating Temperature 0° C to 40° C (32° F to 104° F) Storage Temperature -25° C to 70° C (-13° F to 158° F) Operating Humidity Operating Altitude Range 52 5% to 95% non-condensing Up to 3,000 m (9,843 ft)
AT-9006 Series Installation Guide Power Specifications Maximum Power Consumption AT-9006T: 150 W AT-9006SX/SC and AT-9006LX/SC: 95 W AC Input Voltage AT-9006T: 85-254 VAC, 1.5-3.0A, 50/60 Hz AT-9006SX/SC and AT-9006LX/SC: 115-230 VAC 1.4-2.8A, 50/60 Hz Frequency DC Redundant Power Voltage 50/60 Hz ± 3 cycles of nominal input frequency +3.
Technical Specifications Safety and Electromagnetic Emissions Certifications Safety UL 1950, CSA 22.2 No.
AT-9006 Series Installation Guide Pin Assignment Table 5 shows the pin assignments for the R.P.S. Input port on the back of the switch. (Pin numbers 1 through 8 are the bottom row of pins on the connector, with pin 1 in the bottom right corner. Pin numbers 9 through 16 are the top row, with pin 9 in the top right position on the connector.) Table 5 R.P.S. Input Port Pin Assignments Pin Number Function 1 +12V dc 2 Remote Sense (RS) +5V dc 3 RS Ground 4 RS +3.
Appendix B Switch Default Settings This appendix lists the factory default settings for the switch. Settings Default IP Address Subnet Mask 0.0.0.0 0.0.0.
Switch Default Settings Settings Default Omega Omega Password No password Omega Time Out Value 5 minutes Local Access Enabled Remote Access (Telnet or SNMP) Enabled Web-based Access Enabled Twisted Pair Ports (AT-9006T) Status Enabled Duplex Mode Auto-Negotiation Speed Auto-Negotiation Backpressure Disabled Flow Control Disabled Broadcast Packets Forwarded Fiber Optic Ports (AT-9006SX/SC and AT-9006LX/SC) Status Enabled Duplex Mode Full-duplex Speed 1000 Mbps VLANs Port-based and Tagged VLANs Enabled Def
Appendix C Translated Electrical Safety and Emission Information Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Translated Electrical Safety and Emission Information Standards: This product meets the following safety standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
AT-9006 Series Installation Guide " 12 PLUGGABLE EQUIPMENT, the socket outlet shall be installed near the equipment and shall be easily accessible. " 13 CAUTION: Air vents must not be blocked and must have free access to the room ambient air for cooling. " 14 OPERATING TEMPERATURE: This product is designed for a maximum ambient temperature of 40° degrees C. " 15 ALL COUNTRIES: Install product in accordance with local and National Electrical Codes.
Translated Electrical Safety and Emission Information Standarder: Dette produkt tilfredsstiller de følgende standarder. "1 Radiofrekvens forstyrrelsesemission "2 ADVARSEL: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger. "3 Immunitet EN50082-1 1997 "4 Elektrisk sikkerhed EN60950, UL 1950, CSA 950 "5 Laser EN60825 EN55022 Klasse A SIKKERHED 62 "6 ADVARSEL Laserprodukt av klasse 1.
AT-9006 Series Installation Guide Eisen: Dit product voldoet aan de volgende eisen. "1 RFI Emissie "2 WAARSCHUWING: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen. "3 Immuniteit EN50082-1 1997 "4 Electrische Veiligheid EN60950, UL 1950, CSA 950 "5 Laser EN60825 EN55022 Klasse A VEILIGHEID "6 WAARSHUWING Klasse-1 laser produkt. "7 WAARCHUWING Neit in de straal staren.
Translated Electrical Safety and Emission Information Normes: ce produit est conforme aux normes de suivantes: "1 Emission d’interférences radioélectriques "2 MISE EN GARDE : dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates.
AT-9006 Series Installation Guide Standardit: Tämä tuote on seuraavien standardien mukainen. "1 Radioaaltojen häirintä "2 VAROITUS: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin. "3 Kestävyys EN50082-1 1997 "4 Sähköturvallisuus EN60950, UL 1950, CSA 950 "5 Laser EN60825 EN55022 Luokka A TURVALLISUUS "6 VAROITUS Luokan 1 Lasertuote. "7 VARIOTUS Älä katso säteeseen.
Translated Electrical Safety and Emission Information Standard: Questo prodotto è conforme ai seguenti standard. "1 Emissione RFI (interferenza di radiofrequenza) EN55022 Classe A "2 AVVERTENZA: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati provvedimenti.
AT-9006 Series Installation Guide Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. "1 RFI stråling "2 ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler. "3 Immunitet EN50082-1 1997 "4 Elektrisk sikkerhet EN60950, UL 1950, CSA 950 "5 Laser EN60825 EN55022 Klasse A SIKKERHET "6 ADVARSEL Laserprodukt av klasse 1. "7 ADVARSAL Stirr ikke på strålen.
Translated Electrical Safety and Emission Information Padrões: Este produto atende aos seguintes padrões. "1 Emissão de interferência de radiofrequência EN55022 Classe A "2 AVISO: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas.
AT-9006 Series Installation Guide Estándares: Este producto cumple con los siguientes estándares. "1 Emisión RFI "2 ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto. "3 Inmunidad EN50082-1 1997 "4 Seguridad eléctrica EN60950, UL 1950, CSA 950 "5 Laser EN60825 EN55022 Clase A SEGURIDAD "6 ¡ADVERTENCIA! Producto láser Clase 1.
Translated Electrical Safety and Emission Information Standarder: Denna produkt uppfyller följande standarder. "1 Radiostörning "2 VARNING: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder. "3 Immunitet EN50082-1 1997 "4 Elsäkerhet EN60950, UL 1950, CSA 950 "5 Laser EN60825 EN55022 Klass A SÄKERHET 70 "6 VARNING! Laserprodukt av klass 1. "7 VARNING! Laserstrålning när enheten är öppen.