AT-RPS8000 Redundant Power Supply for the AT-8300 Series Switches Quick Install Guide PN 613-10816-00 Rev B
Copyright 1999, 2000 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA 94086, USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn International, Corp.
Electrical Safety and Emission Compliance Statement Standards: This product meets the following standards U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Table of Contents Electrical Safety and Emission Compliance Statement ......................iii AT-RPS8000 Redundant Power Supply .................................................... 1 Verifying the Package Contents ........................................................................ 2 Reviewing Safety Precautions ........................................................................... 3 Installing the AT-RPS8000 Unit .......................................................................
AT-RPS8000 Redundant Power Supply The AT-RPS8000 unit is designed to provide redundant power for the AT-8300 Series Ethernet switches. The redundant power supply shares the load of powering the switch with the standard power supply in the Ethernet switch. If one power supply fails, the remaining unit supplies all power to the switch, thereby preventing a system failure. The AT-RPS8000 unit comes with one pre-installed power module (AT-PWR8000) that can supply power to one Ethernet switch.
Verifying the Package Contents Make sure the following items are included in the AT-RPS8000 package. If any of these items are missing or damaged, contact your Allied Telesyn representative. Refer to Appendix D for Allied Telesyn locations.
AT-RPS8000 Quick Install Guide Reviewing Safety Precautions Please review the following safety precautions before you begin the installation procedure. Caution Electric Shock Hazard: To prevent ELECTRIC shock, do not remove cover. No user-serviceable parts inside. This unit contains HAZARDOUS VOLTAGES and should only be opened by a trained and qualified technician. To avoid the possibility of ELECTRIC SHOCK disconnect electric power to the product before connecting or disconnecting the LAN cables.
Installing the AT-RPS8000 Unit This section contains the procedure for installing the AT-RPS8000 unit. You can install the unit on a table or in a standard 19-inch rack. This procedure does not require that you turn OFF the power to the Ethernet switches to which you will be connecting the redundant power supply. To install the unit, follow these steps: 1. Remove the AT-RPS8000 for the shipping package and store the packing material in a safe place. 2.
AT-RPS8000 Quick Install Guide Note Ensure that air flow is unrestricted around the AT-RPS8000 unit. 4. Attach the provided DC power cord to the DC output connector on the back panel of the AT-RPS8000 unit, directly behind the pre-installed AT-PWR8000. (Refer to Figure 4 for the DC output connector.) ON/OFF Switch AC Power Connector DC Power Output Connector Figure 4 Back Panel of the AT-RPS8000 Unit 5. Connect the other end of the DC power cord to the R.P.S.
8. Turn on the AT-RPS8000 using the switch on the back panel of the unit. (Refer to Figure 4 for the ON/OFF switch.) 9. Make sure the LED on the front of the AT-PWR8000 module is solid green. 10. Make sure the RPS LED on the front of the Ethernet switch is solid green to indicate a good connection to the AT-PWR8000 module. Installing Additional AT-PWR8000 Modules The AT-RPS8000 can supply redundant power for up to four Ethernet switches. Initially, it contains one pre-installed AT-PWR8000 module.
AT-RPS8000 Quick Install Guide 4. Attach the other end of the DC power cord to the R.P.S. Input connector on the back panel of the Ethernet switch. (Refer to Figure 5 for the R.P.S. Input connector.) 5. Slide the new AT-PWR8000 module into the AT-RPS8000 unit. Use the handle, shown in Figure 7, to guide the module into the unit. Captive Screws Handle Figure 7 Installing an Additional AT-PWR8000 Module 6.
R.P.S. Output Connector Specifications Table 1 shows the pin assignments for the R.P.S. Output connectors located on the back panel of the AT-RPS8000 unit. Table 1 R.P.S. Output Connector Pin Assignments Pin Number Function 1 +12V dc 2 Remote Sense (RS) +5V dc 3 RS Ground 4 RS +3.3V dc 5 Redundant Power Supply (RPS) present 6 Ground (+3.3V dc Return) 7 Ground (+5V dc Return) 8 +5V dc 9 Ground (+12V dc Return) 10 +3.3V dc 11 Ground (+3.3 dc Return) 12 +3.3V dc 13 Ground (+3.
Appendix A Translated Electrical Safety and Emissions Information Standards: This product meets the following standards: U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
!9 ELECTRICAL - CORD NOTICE Use power cord, maximum 4.5 meters long, rated 10 amp minimum, 250V, made of cordage molded IEC 320 connector on one end and on the other end a plug approved by the country of end use. ! 10 PLUGGABLE EQUIPMENT, the socket outlet shall be installed near the equipment and shall be easily accessible. ! 11 CAUTION: Air vents must not be blocked and must have free access to the room ambient air for cooling.
AT-RPS8000 Quick Install Guide Standarder: Dette produkt tilfredsstiller de følgende standarder. !1 Radiofrekvens forstyrrelsesemission !2 ADVARSEL: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger.
Eisen: Dit product voldoet aan de volgende eisen. !1 RFI Emissie !2 WAARSCHUWING: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen. !3 Immuniteit EN50082-1 1997 !4 Electrische Veiligheid EN60950, UL1950, CSA 950 EN55022 Klasse A VEILIGHEID !5 WAARSCHUWINGEN MET BETREKKING TOT ELEKTRICITEIT WAARSCHUWING: GEVAAR VOOR ELEKTRISCHE SCHOKKEN Verwijder het deksel niet, teneinde ELEKTRISCHE schokken te voorkomen.
AT-RPS8000 Quick Install Guide Normes: ce produit est conforme aux normes de suivantes: !1 Emission d’interférences radioélectriques !2 MISE EN GARDE : dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates.
Standardit: Tämä tuote on seuraavien standardien mukainen. !1 Radioaaltojen häirintä !2 VAROITUS: Kotiolosuhteissa tämälaite voi aiheuttaa radioaaltojen häiröitä,missätapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin. !3 Kestävyys EN500821-1 1997 !4 Sähköturvallisuus EN60950, UL1950, CSA 950 EN55022 Luokka A TURVALLISUUS !5 SÄHKÖÖN LIITTYVIÄ HUOMAUTUKSIA VAROITUS: SÄHKÖISKUVAARA Estääksesi SÄHKÖISKUN älä poista kantta.
AT-RPS8000 Quick Install Guide Standard: Questo prodotto è conforme ai seguenti standard. !1 Emissione RFI (interferenza di radiofrequenza) EN55022 Classe A !2 AVVERTENZA: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati provvedimenti.
Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. !1 RFI stråling !2 ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler. !3 Immunitet EN500821-1 1997 !4 Elektrisk sikkerhet EN60950, UL1950, CSA 950 EN55022 Klasse A SIKKERHET !5 ELEKTRISITET ADVARSEL: FARE FOR ELEKTRISK SJOKK For å unngå ELEKTRISK sjokk, må dekslet ikke tas av.
AT-RPS8000 Quick Install Guide Padrões: Este produto atende aos seguintes padrões !1 Emissão de interferência de radiofrequência !2 AVISO: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas.
Estándares: Este producto cumple con los siguientes estándares !1 Emisión RFI !2 ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto. !3 Inmunidad EN50082-1 1997 !4 Seguridad eléctrica EN60950, UL1950, CSA 950 EN55022 Clase SEGURIDAD !5 AVISOS ELECTRICOS ADVERTENCIA: PELIGRO DE ELECTROCHOQUE Para evitar un ELECTROCHOQUE, no quite la tapa.
AT-RPS8000 Quick Install Guide Standarder: Denna produkt uppfyller följande standarder. !1 Radiostörning !2 VARNING: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder. !3 Immunitet EN50082-1 1997 !4 Elsäkerhet EN60950, UL1950, CSA 950 EN55022 Klass A SÄKERHET !5 TILLKÄNNAGIVANDEN BETRÄFFANDE ELEKTRICITETSRISK: RISK FÖR ELEKTRISK STÖTFör att undvika ELEKTRISK stöt, ta ej av locket.
Appendix B AT-RPS8000 Quick Install Guide Feedback Please tell us what additional information you would like to see discussed in this guide. If there are topics you would like information on that were not covered in this guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of this guide.
Appendix C Technical Support Fax Order Name_________________________________________________________________ Company _____________________________________________________________ Address ______________________________________________________________ City ______________________ State/Province_______________________________ Zip/Postal Code __________________ Country_______________________________ Phone ______________________________ Fax_______________________________ Incident Summary Model number of Allied
Appendix D Where To Find Us For Technical Support or Service Location Phone Fax Americas United States, Canada, Mexico, Central America, South America 1 (800) 428-4835 1 (503) 639-3176 Asia Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India, Hong Kong (+65) 3815-612 (+65) 3833-830 Australia Australia, New Zealand 1 (800) 000-880 (+61) 2-9438-4966 France France, Belgium, Luxembourg, The Netherlands, Middle East, Africa (+33) 1-60-92-15-25 (+33) 1-69-28-37-49 Ge