60
Table 3 AT-PB100 Series Media Converters
Note 1: Maximum distance can only be obtained when the UTP/STP cabling is installed and verified to
TIA/EIA 568A Commercial Building Telecommunications Cabling Standard.
Note 2: Maximum distance for 100 Mbps Optical Datalinks are dependent on the following factors:
type of optical fiber, duplex mode of both end-nodes, and maximum optical loss budget for
each of the optical fiber at the operating optical wavelength.
Model
100Base-FX Port 100Base-TX Port
Connector
Maximum
Distance
Connector
Maximum
Distance
AT-PB101 ST 2 km (1.2 mi) RJ-45
100 m
(328 ft)
AT-PB102 SC 2 km (1.2 mi) RJ-45
100 m
(328 ft)
AT-PB103/1 SC 15 km (9.3 mi) RJ-45
100 m
(328 ft)
AT-PB103/2 SC 40 km (24.8 mi) RJ-45
100 m