Upgrading Stand-alone AT-9400 Switches
You can upgrade a stand-alone switch from a local management session with either XMODEM
or TFTP, or from a remote Telnet, SSH, or web browser session with TFTP. For instructions,
refer to the AT-S63 documentation set.
After you have upgraded the management software on a stand-alone switch, you need to check
its stack ID number. Starting in Version 4.0.0 stand-alone switches that have a static ID number
use the stack configuration file instead of the stand-alone configuration file as their active
configuration file. In previous versions, the stack configuration file was used only when a switch
detected that it was a master switch or a backup master switch of a stack. The purpose of this
change is to make it possible for a master switch and a backup master switch to maintain their
stack configuration settings if the switches revert to stand-alone units should a stack encounter a
problem.
When a stand-alone switch that has a static ID number is upgraded to Version 4.0.0 or 4.1.0, it
uses the stack configuration file instead of the stand-alone file after it resets. This may give the
impression that it has lost all of its configuration settings. To remedy this, you must change the
stack ID number assignment from static to automatic. Stand-alone switches that have an
automatic stack ID assignment always use the stand-alone configuration file.
To check the switch’s stack ID number:
1. Log on the switch as the manager.
2. Enter the following command to display the switch’s current stack ID number:
show stack
Here is an example of the information:
3. If the Stack Mode parameter is AUTO, you are finished updating the stand-alone switch.
However, if it is set to STATIC, you need to change the Stack Mode to automatic with this
command:
set stack moduleid=
n
newmoduleid=auto
The variable n is the current value of the Stack ID parameter in the display. For example, if
the current value of the parameter is 1, the command would be:
set stack moduleid=1 newmoduleid=auto
4. After entering the command, you need to reset the switch with this command because your
change to the switch’s ID assignment does not take affect until the unit is reset:
restart reboot
5. After the switch has completed the reset, log on again as the manager.
6. Enter this command again:
show stack
7. Verify that the Stack Mode is now AUTO. If it is, then you are finished updating the stand-
alone switch. If it is still STATIC, try repeating the command in step 3 and reset the unit.
Local MAC Addr :00:30:84:00:00:03
Standalone Mode ID :1
Stack Mode :AUTO
Stack ID :1
Stack Priority :16