User guide
Table Of Contents
- Contents
- Figures
- Tables
- Preface
- Section I
- Basic Operations
- Chapter 1
- Basic Switch Parameters
- Configuring the Switch’s Name, Location, and Contact
- Changing the Manager and Operator Passwords
- Setting the System Date and Time
- Rebooting a Switch
- Pinging a Remote System
- Returning the AT-S63 Management Software to the Factory Default Values
- Displaying the IP Address of the Local Interface
- Displaying System Information
- Chapter 2
- Port Parameters
- Chapter 3
- Enhanced Stacking
- Chapter 4
- SNMPv1 and SNMPv2c
- Chapter 5
- MAC Address Table
- Chapter 6
- Static Port Trunks
- Chapter 7
- Port Mirroring
- Section II
- Advanced Operations
- Chapter 8
- File System
- Chapter 9
- File Downloads and Uploads
- Chapter 10
- Event Logs and Syslog Client
- Chapter 11
- Classifiers
- Chapter 12
- Access Control Lists
- Chapter 13
- Class of Service
- Chapter 14
- Quality of Service
- Chapter 15
- Denial of Service Defenses
- Chapter 16
- IGMP Snooping
- Section III
- SNMPv3
- Chapter 17
- SNMPv3
- Configuring the SNMPv3 Protocol
- Enabling or Disabling SNMP Management
- Configuring the SNMPv3 User Table
- Configuring the SNMPv3 View Table
- Configuring the SNMPv3 Access Table
- Configuring the SNMPv3 SecurityToGroup Table
- Configuring the SNMPv3 Notify Table
- Configuring the SNMPv3 Target Address Table
- Configuring the SNMPv3 Target Parameters Table
- Configuring the SNMPv3 Community Table
- Displaying SNMPv3 Tables
- Section IV
- Spanning Tree Protocols
- Chapter 18
- Spanning Tree and Rapid Spanning Tree Protocols
- Chapter 19
- Multiple Spanning Tree Protocol
- Section V
- Virtual LANs
- Chapter 20
- Port-based and Tagged VLANs
- Chapter 21
- GARP VLAN Registration Protocol
- Section VI
- Port Security
- Chapter 22
- MAC Address-based Port Security
- Chapter 23
- 802.1x Port-based Network Access Control
- Section VII
- Management Security
- Chapter 24
- Encryption Keys, PKI, and SSL
- Chapter 25
- Secure Shell (SSH)
- Chapter 26
- TACACS+ and RADIUS Protocols
- Chapter 27
- Management Access Control List
- Index

AT-S63 Management Software Web Browser User’s Guide
Section III: SNMPv3 211
privacy protocol for this User Table entry. With this selection,
messages transmitted between the host and the switch are encrypted
with the DES protocol.
None
Select this value if you do not want a privacy protocol for this User
Table entry. With this selection, messages transmitted between the
host and the switch are not encrypted.
10. In the Privacy Password field, enter a privacy password of up to 32
alphanumeric characters.
11. In the Confirm Privacy Password field, re-enter the privacy password.
12. In the Storage Type field, enter one of the following storage options for
this table entry:
Volatile
Select this storage type if you do not want the ability to save an entry in
the User Table. After making changes to an User Table entry with a
Volatile storage type, the Save Config option is not displayed on the
Configuration menu.
NonVolatile
Select this storage type if you want the ability to save an entry in the
User Table. After making changes to an User Table entry with a
NonVolatile storage type, the Save Config option is displayed on the
Configuration menu. Allied Telesis recommends this storage type.
Note
The Row Status parameter is a read-only field in the web browser
interface. The Active value indicates the SNMPv3 User Table entry
takes effect immediately.
13. Click Apply to update the SNMPv3 User Table.
14. To permanently save your changes, select the Save Config option in
the Configuration menu.
Deleting a User
Table Entry
To delete an entry in the SNMPv3 User Table, perform the following
procedure:
1. From the home page, select Configuration.
The Configuration System page is displayed with the General tab
selected by default, as shown in Figure 1 on page 28.
2. Select the SNMP tab.
The SNMP tab is shown in Figure 75 on page 206.