Manual
Table Of Contents
- Contents
- Figures
- Tables
- Preface
- Section I
- Basic Operations
- Chapter 1
- Starting a Web Browser Management Session
- Chapter 2
- Basic Switch Parameters
- Configuring the Switch’s Name, Location, and Contact
- Changing the Manager and Operator Passwords
- Setting the System Date and Time
- Rebooting a Switch
- Pinging a Remote System
- Returning the AT-S63 Management Software to the Factory Default Values
- Displaying the IP Address of the Local Interface
- Displaying System Information
- Chapter 3
- Enhanced Stacking
- Chapter 4
- SNMPv1 and SNMPv2c
- Chapter 5
- Port Parameters
- Chapter 6
- MAC Address Table
- Chapter 7
- Static Port Trunks
- Chapter 8
- Port Mirroring
- Section II
- Advanced Operations
- Chapter 9
- File System
- Chapter 10
- File Downloads and Uploads
- Chapter 11
- Event Logs and Syslog Servers
- Chapter 12
- Classifiers
- Chapter 13
- Access Control Lists
- Chapter 14
- Class of Service
- Chapter 15
- Quality of Service
- Chapter 16
- Denial of Service Defense
- Chapter 17
- IGMP Snooping
- Section III
- SNMPv3
- Chapter 18
- SNMPv3
- Configuring the SNMPv3 Protocol
- Enabling or Disabling SNMP Management
- Configuring the SNMPv3 User Table
- Configuring the SNMPv3 View Table
- Configuring the SNMPv3 Access Table
- Configuring the SNMPv3 SecurityToGroup Table
- Configuring the SNMPv3 Notify Table
- Configuring the SNMPv3 Target Address Table
- Configuring the SNMPv3 Target Parameters Table
- Configuring the SNMPv3 Community Table
- Displaying SNMPv3 Tables
- Section IV
- Spanning Tree Protocols
- Chapter 19
- Spanning Tree and Rapid Spanning Tree Protocols
- Chapter 20
- Multiple Spanning Tree Protocol
- Section V
- Virtual LANs
- Chapter 21
- Port-based and Tagged VLANs
- Chapter 22
- GARP VLAN Registration Protocol
- Section VI
- Port Security
- Chapter 23
- MAC Address-based Port Security
- Chapter 24
- 802.1x Port-based Network Access Control
- Section VII
- Management Security
- Chapter 25
- Encryption Keys, PKI, and SSL
- Chapter 26
- Secure Shell (SSH)
- Chapter 27
- TACACS+ and RADIUS Protocols
- Chapter 28
- Management Access Control List
- Index

AT-S63 Management Software Web Browser Interface User’s Guide
Section III: SNMPv3 239
Included
Enter this value to permit the View Name to see the subtree specified
above.
Excluded
Enter this value to not permit the View Name to see the subtree
specified above.
7. In the Storage Type field, enter a storage type for this table entry:
Volatile
Select this storage type if you do not want the ability to save an entry in
the Target Parameters Table. After making changes to an Target
Parameters Table entry with a Volatile storage type, the Save Config
option is not displayed on the Configuration menu.
NonVolatile
Select this storage type if you want the ability to save an entry in the
View Table. After making changes to a View Table entry with a
NonVolatile storage type, the Save Config option is displayed on the
Configuration menu. Allied Telesyn recommends this storage type.
Note
The Row Status parameter is a read-only field in the web browser
interface. The Active value indicates the SNMPv3 View Table entry
takes effect immediately.
8. Click Apply.
9. To permanently save your changes, select the Save Config option in
the Configuration menu.