Datasheet
SUBCATEGORY FEATURE AT-FS708/POE AT-FS750/24POE AT-8000/8POE AT-8100L/8POE AT-8100L/8POE-E AT-8000S/24POE AT-8100S/24POE AT-8000S/48POE AT-8100S/48POE AT-8624POE-V2
FORM FACTOR
Wall mount / Desktop / Rack mount Wall mount / Desktop / Rack mount Wall mount / Desktop / Rack mount Wall mount / Desktop / Rack mount Wall mount / Desktop / Rack mount
/ Stack
Wall mount / Desktop / Rack mount
/ Stack
Wall mount / Desktop / Rack mount
/ Stack
Wall mount / Desktop / Rack mount
/ Stack
Wall mount / Desktop / Rack mount Desktop / Rack mount
SWITCH FUNCTIONALITY
Unmanaged WebSmart Layer 2 Layer 2–4 Layer 2–4 Layer 2 Layer 2–4 Layer 2 Layer 2–4 Layer 3
PORTS AND
MEDIA SUPPORT
10/100TX 8 24 8 8 8 24 24 48 48 24
10/100/1000T 2 1 2 2 2 2 2 2 2
SFP 1 (1000Mbps) 2 (combo) (100 or 1000Mbps) 1 (combo) (1000Mbps) 2 (combo) (100 or 1000Mbps) 2 (combo) (100 or 1000Mbps) 2 (combo) (100 or 1000Mbps) 2 (combo) (100 or 1000Mbps) 2 (combo) (100 or 1000Mbps) 2 (combo) (100 or 1000Mbps) 2 (combo) (1000Mbps)
Modular uplinks 2
MODULAR UPLINKS
1 x 100FX AT-A45
POWER SUPPLY
PSU type Fixed Internal Fixed Internal Fixed Internal Fixed Internal Fixed Internal Fixed Internal 2 Fixed Internal Fixed Internal 2 Fixed Internal Fixed Internal
Redundant PSU option
■
Redundant PSU chassis (inc 1 PSU) Internal Internal AT-RPS3104
Additional redundant PSU AT-PWR3101
POWER OVER ETHERNET
IEEE 802.3af (PoE)
■ ■ ■ ■
■ ■ ■ ■ ■ ■
IEEE 802.3at (PoE+)
■
■ ■ ■
PoE-enabled ports 8 12 8 8 8 24 24 48 48 24
Max number of full power ports 4 6 6 6 6 12 12 24 12 24
Mode A A B B B B B B B A
PoE power 65W 100W 95W 185W 185W 185W 370W 375W 370W 400W
SCALABILITY
MAC address table size 8K 8K 8K 16K 16K 8K 16K 16K 8K
Stacking ■ (6) ■ (8) ■ (8)
ENVIRONMENTAL
Cooling Fanless Fan Fan Fan Fan Fan Fan Fan Fan Fan
Variable speed fan
■
■ ■ ■
Eco-friendly
■ ■ ■
■ ■ ■
Temperature range 0 to 40°C 0 to 40°C 0 to 40°C 0 to 40°C 0 to 50°C 0 to 40°C 0 to 40°C 0 to 40°C 0 to 40°C 0 to 40°C
MANAGEMENT
Web
■ ■
■ ■ ■ ■ ■ ■
CLI
■ ■
■ ■ ■ ■ ■ ■
Telnet
■ ■
■ ■ ■ ■ ■ ■
SNMP
■ ■ ■
■ ■ ■ ■ ■ ■
NETWORK RESILIENCE
Spanning Tree
■ ■ ■
■ ■ ■ ■ ■ ■
Link aggregation (LACP)
■ ■
■ ■ ■ ■ ■ ■
QoS
IEEE 802.1p priority queues 4 8 8 4 8 4 8 4
SECURITY
IEEE 802.1Q VLANs 256 255 4096 4096 256 4096 256 4096 256
RADIUS
■ ■ ■
■ ■ ■ ■ ■ ■
TACACS
■
■ ■ ■ ■ ■ ■
SSH/SSL
■
■ ■ ■ ■ ■ ■
IEEE 802.1x
■ ■ ■
■ ■ ■ ■ ■ ■
DoS protection
■
ROUTING
Basic Basic Basic Basic ■ (Full)
DIMENSIONS
(W x D x H)
26.5 x 16.2 x 4.3 cm
10.4 x 6.4 x 1.7 in
44 x 32.2 x 4.35 cm
17.3 x 12.7 x 1.7 in
33 x 22.8 x 4.3 cm
13 x 8 x 1.7 in
33 x 22.8 x 4.3 cm
13 x 8 x 1.72 in
33 x 22.8 x 4.3 cm
13 x 8 x 1.72 in
44 x 25.7 x 4.3 cm
17.3 x 10.1 x 1.7 in
44 x 29.1 x 4.3 cm
17.34 x 14.46 x 1.72 in
44 x 34.7 x 4.3 cm
17.3 x 13.7 x 1.7 in
44 x 29.1 x 4.3 cm
17.34 x 14.46 x 1.72 in
43.8 x 40.6 x 4.4 cm
17.24 x 15.98 x 1.73 in
Weight 1.9 Kg / 4.2 lb 4.133 Kg / 9.11 lb 2.2 Kg / 4.9 lb 2.29 Kg / 5.05 lb 2.29 Kg / 5.05 lb 3.7 Kg / 8.15 lb 3.62 kg / 8.1 lb 5.6 Kg / 12.34 lb 5.42 kg / 11.95 lb 6 Kg / 13.22 lb
» Redundant Power
Does a service such as emergency VoIP
telephony or video intrusion protection
need to be provided even in the event of
a fault? A switch capable of providing dual
power sources must be selected.
Cable Types
PoE is designed to run over existing standard Ethernet cables. However, for Fast Ethernet,
there are two modes of operation:
» Mode A – Injects power onto the data wires
» Mode B – Uses “spade pairs” to transmit the power.
Gigabit copper connections use all four pairs to connect.
Summer 2012 | 21