AT-FS713FC/xx AT-FS717FC/xx 10/100 Mbps Ethernet Switches Installation Guide PN 613-50268-00 Rev A
Copyright 2001 Allied Telesyn International Corp. 960 Stewart Drive Suite B, Sunnyvale CA 94085, USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn International Corp.
Electrical Safety and Emission Compliance Statement Standards: This product meets the following standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Table of Contents Electrical Safety and Emission Compliance Statement ......................iii Welcome to Allied Telesyn ......................................................................... vii Where to Find Web-based Guides ................................................................... vii Document Conventions .................................................................................... vii Contacting Allied Telesyn Technical Support................................................
Table of Contents Chapter 2 Installing the Switch ................................................................................... 11 Reviewing Safety Guidelines ........................................................................... 11 Verifying the Package Contents ...................................................................... 12 Planning the Installation ................................................................................. 13 Selecting a Site ..................................
Welcome to Allied Telesyn The guide contains instructions on how to install the AT-FS713FC/xx and AT-FS717FC/xx Series Ethernet Switches. Where to Find Web-based Guides The Allied Telesyn web site at www.alliedtelesyn.com provides you with an easy way to access the most recent documentation, software, and technical information for all of our products. For product guides, select “Support & Services” from our web site.
Contacting Allied Telesyn Technical Support You can contact Allied Telesyn technical support online or by telephone, fax, or e-mail. Online Support You can request technical support online by filling out the Technical Enquiry Form or by accessing the Knowledge Base. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions. To access the Knowledge Base, select “Support & Services”, then select “Help” from www.alliedtelesyn.com.
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide Technical Support E-mail Addresses United States and Canada TS1@alliedtelesyn.com Latin America, Mexico, Puerto Rico, Caribbean, and Virgin Islands latin_america@alliedtelesyn.com Europe support_europe@alliedtelesyn.com Returning Products Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense.
For Sales or Corporate Information You can contact Allied Telesyn for sales or corporate information at the location listed below: Allied Telesyn International Corp. 19800 North Creek Parkway, Suite 200 Bothell, WA 98011 Tel: 1 (425) 487-8880 Fax: 1 (425) 489-9191 Tell Us What You Think If you have any comments or suggestions on how we might improve this or other Allied Telesyn documents, please fill out the General Enquiry Form online. This form can be accessed by selecting “Contact Us” at www.
Chapter 1 Overview The AT-FS713FC/xx and AT-FS717FC/xx Series Fast Ethernet Switches include the following models: q q q q q q AT-FS713FC/FJ AT-FS713FC/LC AT-FS713FC/MT AT-FS713FC/SC AT-FS713FC/ST AT-FS713FC/VF q q q q q q AT-FS717FC/FJ AT-FS717FC/LC AT-FS717FC/MT AT-FS717FC/SC AT-FS717FC/ST AT-FS717FC/VF These units are unmanaged Layer 2 switches.
Figure 1 illustrates the front and back panels of an AT-FS713FC/xx Series Switch. LEDs Duplex Switch Front Panel AT-FS713FC/MT 100FX 10/100TX 10Base-T / 100Base-TX 12 Port Fast Ethernet Switch with 100FX Uplink 11 9 7 5 3 1 LNK/ ACT 100M 100FX DUPLEX LNK/ ACT HALF LNK/ ACT PWR FULL 100M FD 13 13 12 10 8 6 4 2 Back Panel 1 3 5 7 9 11 2 4 6 8 10 12 120-240V 50-60Hz 0.
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide Table 1 lists the maximum operating distances for the AT-FS713FC/xx Series Switches. Table 1 AT-FS713FC/xx Series Maximum Operating Distances 10/100Base-TX Model 100Base-FX Connector Maximum Maximum Connector Operating Distance Operating Distance AT-FS713FC/FJ RJ-45 100 m (328 ft) FJ 2 km (1.2 mi) AT-FS713FC/LC RJ-45 100 m (328 ft) LC 2 km (1.2 mi) AT-FS713FC/MT RJ-45 100 m (328 ft) MT 2 km (1.
Features q LEDs for unit and port status q Auto MDI/MDI-X for the twisted pair ports q Half- or full-duplex operation on the fiber optic port q Auto-negotiation of the duplex mode on the twisted pair ports q RJ-45 twisted pair connectors q FJ, LC, MT, SC, ST, or VF fiber optic connector q Store and forward Ethernet packet handling q MAC address table with a capacity of 4,000 addresses Status LEDs Table 3 defines the LEDs on the AT-FS713FC/xx and AT-FS717FC/xx Series Switches.
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide Twisted Pair Ports The AT-FS713FC/xx and AT-FS717FC/xx Series Switches have twelve and sixteen 10/100Base-TX twisted pair ports, respectively. Port Speed The twisted pair ports are compliant with the 10Base-T and 10Base-TX standards and are capable of either 10 Mbps or 100 Mbps operation. The ports are IEEE 802.3u auto-negotiation compliant.
Fiber Optic Port The AT-FS713FC/xx and AT-FS717FC/xx Series Switches have one 100Base-FX fiber optic port. The fiber optic port has a FJ, LC, MT, SC, ST, or VF connector, depending on the model. Port Speed The fiber optic port is compliant with the 100Base-FX standard and has a fixed operating speed of 100 Mbps. The end-node connected to the fiber optic port on the switch must also be able to operate at 100 Mbps. Duplex Mode Duplex mode refers to the way an end-node sends and receives data on the network.
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide MAC Address Table Up to 4,000 MAC addresses can be stored in the switch’s MAC address table. The switch’s self-learning feature will learn all new addresses in real-time after power-up. If the source address of an incoming packet is not found in the MAC address table, the switch will update the table with the new address.
Network Topologies The AT-FS713FC/xx or AT-FS717FC/xx Series Switches can be used in several network topologies. Some of these topologies are described below. Workgroup Topology Figure 3 illustrates a workgroup topology where each end-node is connected directly to a port on an AT-FS713FC/SC switch, giving each end-node a dedicated 10 Mbps or 100 Mbps link. AT-FS713FC/SC 1 3 5 7 9 11 120-240V TX 2 4 6 8 10 12 RX 13 10 Mbps 100 Mbps Figure 3 Power Workgroup Topology 8 50-60Hz 0.
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide Ethernet Hub Workgroup Topology Figure 4 illustrates an Ethernet hub workgroup topology where an AT-FS713FC/SC is used to connect together four 10/100 Mbps Ethernet hubs. This allows the switch to function as a bridge between the different workgroups by controlling the flow of data between the workgroups.
Backbone Topology If your network consists of several AT-FS713FC/xx or AT-FS717FC/xx Series Switches, then you will probably want to connect them together to form an integrated network. Here the fiber optic ports can be extremely useful. You can use the ports to create a fiber optic backbone. With a maximum operating distance of 2 kilometers (1.2 miles), the ports can be used to connect together switches that are physically far apart.
Chapter 2 Installing the Switch This chapter contains desktop and wall-mounting installation instructions for an AT-FS713FC/xx or AT-FS717FC/xx Series Switch. Reviewing Safety Guidelines Please review the following safety guidelines before you begin to install the switch. Warning Class 1 laser product. $ 5 Warning Do not stare into the laser beam. $ 6 Warning Electric Shock Hazard: To prevent electric shock, do not remove the cover. There are no user-serviceable parts inside.
Caution Pluggable Equipment: The socket outlet should be installed near the equipment and should be easily accessible. $ 10 Caution Air vents: The air vents must not be blocked on the unit and must have free access to the room ambient air for cooling. $ 11 Caution Operating Temperature: This product is designed for a maximum ambient temperature of 40°C. $ 12 Caution All Countries: Install this product in accordance with local and National Electric Codes.
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide Planning the Installation Be sure to observe the following guidelines when planning the installation of your switch. q The end-node connected to the 100Base-FX fiber optic port must be able to operate at 100 Mbps. q The end-node connected to a 10/100Base-TX twisted pair port must be able to operate at 10 or 100 Mbps. q The end-node connected to a port on the switch can be a network adapter card, repeater, router, hub, or another switch.
q Refer to Table 6 for the cabling specifications for the fiber optic port operating in half-duplex mode.
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide Installing the Switch On a Table or Desktop To wall-mount the switch, refer to “Wall-mounting the Switch” on page 16. To install the switch on a table or desktop, perform the following procedure: 1. Remove all components from the shipping package and store the packaging material in a safe location. Note Do not remove the dust covers from the fiber optic port until you are ready to connect the fiber optic cable.
Wall-mounting the Switch The switch can be mounted either vertically or horizontally on a wall using the keyholes on the bottom of the chassis. For wall-mount installation, you will need two panhead screws and plastic anchors. To wall-mount the switch, perform the following procedure: 1. If attached, remove the rubber feet, data cables, and power cord from the switch. 2. Select a wall location for the device. 3. Install the plastic anchors and panhead screws 100 millimeters (3.
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide Warranty Registration When you have finished installing the product, register your product by completing the enclosed warranty card and sending it in. You can also fill out the registration online by selecting “Warranties” under “Support & Services” from www.alliedtelesyn.com.
Chapter 3 Troubleshooting Follow the guidelines below to test and troubleshoot the installation in the event a problem occurs. If the PWR LED is OFF, do the following: q Make sure that the power cord is securely connected to the wall outlet and the power connector on the back of the switch. q Verify that the power outlet has power by connecting another device to it. q Try connecting the switch to another power source. q Try using another power cord.
If the LNK/ACT LED for the fiber optic port is OFF, do the following: q Verify that the end-node connected to the port is ON and is operating properly. q Check that the fiber optic cable is securely connected to the port on the switch and to the port on the end-node. q Check to be sure that the end-node connected to the port is operating at 100 Mbps.
Appendix A Technical Specifications Physical Dimensions: WxDxH 1.7 cm x 17.9 cm x 9.8 cm (0.7 in x 7 in x 3.9 in) Weight: 0.42 kg (0.9 lbs) Temperature Maximum Operating: 0° to 40° C (32° to 104° F) Maximum Storage: -25° to 70° C (-13° to 158° F) Relative Humidity: 5% to 95% non-condensing Operating Altitude: Up to 3,000 meters (9,843 feet) Electrical Rating Input Supply Voltage: 100-240 V AC Maximum Current: 0.
Fiber Optic Port Specifications Table 7 through Table 10 list the specifications for the fiber optic port. Table 7 Fiber Optic Transmitter Model All models Launch Power (dBm)1 Fiber Optic Diameter (microns) Optical Frequency Multimode 50/125 Multimode 62.5/125 Fiber Type Maximum Average Minimum 1310 nm -14.0 -20.3 -22.5 1310 nm -14.0 -16.8 -19.0 1. The launch power is measured at one meter from the transmitter.
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide Table 10 Fiber Optic Loss Specification (Benchmark) Fiber Type Multimode Fiber Optic Diameter Optical Frequency Typical Loss Factor Worst Case Loss Factor Bandwidth 50/125 microns 1310 nm 1.00 dB/km 1.50 dB/km 400 Mhz-km 62.5/125 microns 1310 nm 1.00 dB/km 1.50 dB/km 500 Mhz-km Pinout Assignments Figure 6 shows the pin assignments of the RJ-45 connector.
Appendix B Translated Electrical Safety Emission Information Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. Belangrijk: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Standards: This product meets the following standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
$ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide 13 All Countries: Install product in accordance with local and National Electrical Codes. Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. 1 Hochfrequenzstörung 2 Warnung: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen.
$ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ 28 7 ELEKTRISKE FORHOLDSREGLER Advarsel: RISIKO FOR ELEKTRISK STØD For at forebygge ELEKTRISK stød, undlad at åbne apparatet. Der er ingen indre dele, der kan repareres af brugeren. Denne enhed indeholder LIVSFARLIGE STRØMSPÆNDINGER og bør kun åbnes af en uddannet og kvalificeret tekniker. For at undgå risiko for ELEKTRISK STØD, afbrydes den elektriske strøm til produktet, før LAN-kablerne monteres eller afmonteres.
$ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide 11 Opgelet: De ventilatiegaten mogen niet worden gesperd en moeten de omgevingslucht ongehinderd toelaten voor afkoeling. 12 Bedrijfstemperatuur: De omgevingstemperatuur voor dit produkt mag niet meer bedragen dan 40 graden Celsius. 13 Alle Landen: het toestel installeren overeenkomstig de lokale en nationale elektrische voorschriften.
$ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ 30 Standardit: Tämä tuote on seuraavien standardien mukainen. 1 Radioaaltojen häirintä 2 Varoitus: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin. 3 Kestävyys EN55024 4 Sähköturvallisuus UL 1950 (UL/cUL), EN60950 (TUV), EN60825 5 VAROITUS Luokan 1 Lasertuote. 6 Variotus Älä katso säteeseen.
$ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide 7 AVVERTENZE ELETTRICHE Attenzione: PERICOLO DI SCOSSE ELETTRICHE Per evitare SCOSSE ELETTRICHE non asportare il coperchio. Le componenti interne non sono riparabili dall’utente. Questa unità ha TENSIONI PERICOLOSE e va aperta solamente da un tecnico specializzato e qualificato.
$ $ $ $ $ $ $ $ $ $ $ $ $ $ $ 32 12 Driftstemperatur: Dette produktet er konstruert for bruk i maksimum romtemperatur på 40 grader celsius. 13 Alle Land: Produktet må installeres i samsvar med de lokale og nasjonale elektriske koder. Padrões: Este produto atende aos seguintes padrões.
AT-FS713FC/xx and AT-FS717FC/xx Series Installation Guide $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ Estándares: Este producto cumple con los siguientes estándares. 1 Emisión RFI 2 Advertencia: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto. 3 Inmunidad EN55024 4 Seguridad eléctrica UL 1950 (UL/cUL), EN60950 (TUV), EN60825 5 ¡Advertencia! Producto láser Clase 1.
$ $ $ $ $ $ $ 34 7 Tillkännagivanden Beträffande Elektricitetsrisk: RISK FÖR ELEKTRISK STÖTFör att undvika ELEKTRISK stöt, ta ej av locket. Det finns inga delar inuti som behöver underhållas. Denna apparat är under HÖGSPÄNNING och får endast öppnas av en utbildad kvalificerad tekniker. För att undvika ELEKTRISK STÖT, koppla ifrån produktens strömanslutning innan LANkablarna ansluts eller kopplas ur. 8 FARA FÖR BLIXTNEDSLAG Fara: ARBETA EJ på utrustningen eller kablarna vid ÅSKVÄDER.
Appendix C Technical Support Fax Order Name _________________________________________________________________ Company ______________________________________________________________ Address _______________________________________________________________ City______________________ State/Province_______________________________ Zip/Postal Code ________________ Country_______________________________ Phone______________________________ Fax________________________________ Incident Summary Model number of Allied