AT-BMGMT Management Module For the AT-8324SX Fast Ethernet Switch Quick Install Guide PN 613-50119-00 Rev A
Copyright 2000 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA 94086 USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn International, Corp.
Safety Warnings Standards: This product meets the following standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
VIKTIG: Tillegg A inneholder oversatt sikkerhetsinformasjon for installering av dette utstyret. Når du ser , åpner du til Tillegg A for å finne den oversatte sikkerhetsinformasjonen på ønsket språk. IMPORTANTE: O Anexo A contém advertências de segurança traduzidas para instalar este equipamento. Quando vir o símbolo , leia a advertência de segurança traduzida no seu idioma no Anexo A IMPORTANTE: El Apéndice A contiene mensajes de seguridad traducidos para la instalación de este equipo.
Table of Contents Safety Warnings ............................................................................................. iii Table of Contents ........................................................................................... v Welcome to Allied Telesyn ......................................................................... vii Where to Find Web-based Guides.................................................................... vii Document Conventions........................................
Welcome to Allied Telesyn This guide contains instructions on how to install the AT-BMGMT Management Module in an AT-8324SX Fast Ethernet Switch. Where to Find Web-based Guides The Allied Telesyn web site at www.alliedtelesyn.com provides you with an easy way to access the most recent documentation and technical information for all of our products. All web-based documents relating to this product and other Allied Telesyn products can be downloaded from the web site in pdf format.
Document Conventions This guide uses several conventions that you should become familiar with first before you begin to install the product. Note A note provides additional information. Caution A caution indicates that performing or omitting a specific action may result in equipment damage or loss of data. Warning A warning indicates that performing or omitting a specific action may result in bodily injury.
AT-BMGMT Quick Install Guide Australia Tel: 1 (800) 000-880 Fax: (+61) 2-9438-4966 Japan Tel: (+81) 3-3443-5640 Fax: (+81) 3-3443-2443 France France, Belgium, Luxembourg, The Netherlands, Middle East, Africa Tel: (+33) 0-1-60-92-15-25 Fax: (+33) 0-1-69-28-37-49 United Kingdom United Kingdom, Denmark, Norway, Sweden, Finland Tel: (+0044) 1235-442500 Fax: (+44) 1-235-442680 Technical Support E-mail Addresses United States and Canada TS1@alliedtelesyn.
FTP Server If you need a device driver for an Allied Telesyn device and you know the name of the driver, you can download the driver by connecting directly to our FTP server at ftp://gateway.centre.com. At login, enter ‘anonymous’. Enter your e-mail address for the password as requested by the server at login. For Sales or Corporate Information Allied Telesyn International, Corp.
Overview The AT-BMGMT Management Module is designed for the AT-8324SX Fast Ethernet Switch. The module can be used to manage an AT-8324SX switch or an AT-8324SX stack. It offers a variety of management options, including SNMP, RMON, and a web-based interface. An RS-232 port on the module provides for out-of-band management.
Installing the AT-BMGMT Management Module The following sections contain instructions on how to install the module. Verifying the Package Contents Check to be sure that your package contains the following items. If any of the items are missing or damaged, contact your Allied Telesyn representative.
AT-BMGMT Quick Install Guide Caution Air vents: The air vents must not be blocked on the unit and must have free access to the room ambient air for cooling. 10 Caution Operating Temperature: This product is designed for a maximum ambient temperature of 40°C. 11 Caution All Countries: Install this product in accordance with local and National Electric Codes. 12 Handling the Module Caution The AT-BMGMT Management Module can be easily damaged by electrostatic discharge.
Installing the Module To install the module, perform the following procedure: 1. Power off the switch by disconnecting the AC power cord from the switch. If the switch is connected to a redundant power unit (RPU), disconnect the DC cable connection to the switch. Caution The switch must be powered off before installing or replacing the module. Installing the module with the switch powered on can damage the module.
AT-BMGMT Quick Install Guide 3. Insert the AT-BMGMT Management Module into the switch. Holding the new module with the text on the front panel upright, carefully slide the module into the slot, ensuring that the edge connector is fully engaged. Once the module is installed, check to be sure that the front panel of the module is flush against the switch. 4. Secure the new module in place by tightening the retainer screws.
4. Flow Control: none Character Set: ASCII Power on the switch or stack. For instructions on how to configure the switch using the AT-S29 management software, refer to the AT-S29 Management Software User’s Guide. If the management module is not functioning properly, see "Troubleshooting" below.
AT-BMGMT Quick Install Guide Technical Specifications Table 1 lists the technical specifications of the module. Table 1 Technical Specifications Physical Specifications Ports One RS-232 serial port Cable Type Standard RS-232 cable Environmental Specifications Operating Temperature 0° C to 50° C (32° to 122° F) Storage Temperature -20° C to 70° C (-4° to 158° F) Operating Humidity 5% to 95% non-condensing Power Specifications Maximum Power Consumption 2 watts Standards IEEE 802.
Connectivity Guidelines Table 2 Console Port to 9-Pin COM Port on PC 8 Switch’s 9-Pin Serial Port CCITT Signal PC’s 9-Pin COM Port 1 DCD ----- DCD ----- 1 2 RXD <----- TXD ----- 3 3 TXD ----- RXD -----> 2 4 DTR ----- DSR -----> 6 5 SGND ----- SGND ----- 5 6 DSR ----- DTR ----- 4 7 RTS ----- CTS -----> 8 8 CTS <----- RTS ----- 7 9 RI ----- RI ----- 9
Appendix A Translated Electrical Safety and Emission Information IMPORTANT: This appendix contains multiple-language translations for the safety statements in this guide. WICHTIG: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. VIGTIGT: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog. BELANGRIJK: Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids.
Standards: This product meets the following standards: U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
AT-BMGMT Quick Install Guide 8 ELECTRICAL - TYPE CLASS 1 EQUIPMENT THIS EQUIPMENT MUST BE EARTHED. Power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts. 9 PLUGGABLE EQUIPMENT, the socket outlet shall be installed near the equipment and shall be easily accessible. 10 CAUTION: Air vents must not be blocked and must have free access to the room ambient air for cooling.
11 BETRIEBSTEMPERATUR: Dieses Produkt wurde für den Betrieb in einer Umgebungstemperatur von nicht mehr als 40° C entworfen. 12 ALLE LÄNDER: Installation muß örtlichen und nationalen elektrischen Vorschriften entsprechen. Standarder: Dette produkt tilfredsstiller de følgende standarder. 1 Radiofrekvens forstyrrelsesemission 2 ADVARSEL: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger.
AT-BMGMT Quick Install Guide Eisen: Dit product voldoet aan de volgende eisen. 1 RFI Emissie 2 WAARSCHUWING: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen. 3 Immuniteit IEC 1000-4-2 (4 kV CD, 8 kV AD) IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line); 0.
Normes: ce produit est conforme aux normes de suivantes: 1 Emission d’interférences radioélectriques 2 MISE EN GARDE : dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates. 3 Immunité IEC 1000-4-2 (4 kV CD, 8 kV AD) IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line); 0.
AT-BMGMT Quick Install Guide Standardit: Tämä tuote on seuraavien standardien mukainen. 1 Radioaaltojen häirintä 2 VAROITUS: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin. 3 Kestävyys IEC 1000-4-2 (4 kV CD, 8 kV AD) IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line); 0.
Standard: Questo prodotto è conforme ai seguenti standard. 1 Emissione RFI (interferenza di radiofrequenza) 2 AVVERTENZA: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati provvedimenti. 3 Immunità IEC 1000-4-2 (4 kV CD, 8 kV AD) IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line); 0.
AT-BMGMT Quick Install Guide Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. 1 RFI stråling 2 ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler. 3 Immunitet IEC 1000-4-2 (4 kV CD, 8 kV AD) IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line); 0.
Padrões: Este produto atende aos seguintes padrões. 1 Emissão de interferência de radiofrequência 2 AVISO: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas. 3 Imunidade IEC 1000-4-2 (4 kV CD, 8 kV AD) IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line); 0.
AT-BMGMT Quick Install Guide Estándares: Este producto cumple con los siguientes estándares. 1 Emisión RFI 2 ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto. 3 Inmunidad IEC 1000-4-2 (4 kV CD, 8 kV AD) IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line); 0.
Standarder: Denna produkt uppfyller följande standarder. 1 Radiostörning 2 VARNING: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder. 3 Immunitet IEC 1000-4-2 (4 kV CD, 8 kV AD) IEC 1000-4-3 (1995) (3 V/m) IEC 1000-4-4 (1995) (1.0 kV - (power line); 0.5 kV - (signal line)) IEC 1000-4-6 (1995) (3 Vrms) EN50082-1 (1995) EN61000-4-2 (1995) EN61000-4-4 (1995) 4 Elsäkerhet CSA/NRTL (CSA 22.2.
Appendix B Technical Support Fax Order Name _________________________________________________________________ Company ______________________________________________________________ Address _______________________________________________________________ City______________________ State/Province_______________________________ Zip/Postal Code ________________ Country_______________________________ Phone ______________________________ Fax_______________________________ Incident Summary Model number of Allied
Appendix C AT-BMGMT Quick Install Guide Feedback Please tell us what additional information you would like to see discussed in this guide. If there are topics you would like information on that were not covered in this guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of this guide.