AT-FS708 AT-FS708E Fast Ethernet Switches Installation Guide PN 613-10801-00 Rev.
Copyright 1999 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA 94086, USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn International, Corp.
Electrical Safety and Installation Requirements STANDARDS: This product meets the following standards U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Electrical Safety and Installation Requirements ELECTRICAL—TYPE CLASS 1 EQUIPMENT THIS EQUIPMENT MUST BE EARTHED. Power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts. ELECTRICAL—CORD NOTICE Use power cord, maximum 4.5 meters long, rated 6 amp minimum, 250V, made of HAR cordage molded IEC 320 connector on one end and on the other end a plug approved by the country of end use.
AT-FS708 and AT-FS708E Switches Installation Guide STANDARDER: Dette produkt tilfredsstiller de følgende standarder. ADVARSEL: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger. Radiofrekvens forstyrrelsesemission EN55022 Klasse A ADVARSEL: Der skal bruges skærmkabler med dette produkt for at opfylde Klasse A emissionsgrænser.
Electrical Safety and Installation Requirements EISEN: Dit product voldoet aan de volgende eisen. WAARSCHUWING: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen. RFI Emissie EN55022 Klasse A WAARSCHUWING: Dit product vereist beschermende kabels in overeenstemming met de limieten van Klasse A emissie.
AT-FS708 and AT-FS708E Switches Installation Guide NORMES: ce produit est conforme aux normes de suivantes: MISE EN GARDE: dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates. Emission d’interférences radioélectriques EN55022 Classe A MISE EN GARDE : conformément aux limites d’émission de la Classe A, ce produit doit être utilisé avec des câbles blindés.
Electrical Safety and Installation Requirements STANDARDIT: Tämä tuote on seuraavien standardien mukainen. VAROITUS: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin. Radioaaltojen häirintä EN55022 Luokka A VAROITUS: Tämä tuote vaatii suojatut kaabelit täyttääkseen A Luokan säteilyrajoitukset.
AT-FS708 and AT-FS708E Switches Installation Guide STANDARD: Questo prodotto è conforme ai seguenti standard. AVVERTENZA: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati provvedimenti. Emissione RFI (interferenza di radiofrequenza) EN55022 Classe A AVVERTENZA: questo prodotto richiede cavi schermati per adeguarsi ai limiti di emissione per gli apparecchi di Classe A.
Electrical Safety and Installation Requirements SIKKERHETSNORMER: Dette produktet tilfredsstiller følgende sikkerhetsnormer. ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler. RFI stråling EN55022 Klasse A ADVARSEL: Det må benyttes isolerte kabler med dette produktet for å tilfredsstille Klasse A strålingsgrenser. Hvis ikke kan dette produktet forårsake radioforstyrrelse.
AT-FS708 and AT-FS708E Switches Installation Guide PADRÕES: Este produto atende aos seguintes padrões. AVISO: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas. Emissão de interferência de radiofrequência EN55022 Classe A AVISO: Este produto requer cabos protegidos a fim de obedecer aos limites de emissão da Classe A.
Electrical Safety and Installation Requirements ESTÁNDARES: Este producto cumple con los siguientes estándares. ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto. Emisión RFI EN55022 Clase A ADVERTENCIA: este producto requiere de cables armados para cumplir con los límites de emisión de Clase A.
AT-FS708 and AT-FS708E Switches Installation Guide STANDARDER: Denna produkt uppfyller följande standarder. VARNING: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder. Radiostörning EN55022 Klass A VARNING: Skärmkabel bör användas med denna produkt för att uppfylla kraven gällande radiostörningar enligt Klass A.
Table of Contents Electrical Safety and Installation Requirements...................................iii Chapter 1 Product Description ....................................................................................... 1 Overview ............................................................................................................. 1 Common Major Features.................................................................................... 2 Physical Description......................................
Appendix A Switch Specifications ................................................................................... 17 Physical Characteristics................................................................................... 17 Standards .......................................................................................................... 17 Cabling Specifications ...................................................................................... 18 Electrical Specifications ......................
Chapter 1 Product Description Overview This chapter describes the features of the following unmanaged Fast Ethernet switches: ❑ AT-FS708 ❑ AT-FS708E Each switch model is described in Table 1: Table 1 Switch Models and Port Description Model AT-FS708 Description Eight auto-negotiating 10/100 Mbps twisted pair RJ45 ports Port 8 MDI and Port 8 MDI-X Total bandwidth of 800 Mbps Internal Power Supply AT-FS708E Eight auto-negotiating 10/100 Mbps twisted pair RJ45 ports Port 8 MDI and Port 8 MDI-X Total b
Product Description Common Major Features These switches come with the following common features: ❑ IEEE 802.3 and IEEE 802.
AT-FS708 and AT-FS708E Switches Installation Guide Physical Description The physical description for the switches includes: ❑ Connectors ❑ Media-Dependent Interface (MDI), Port 8 ❑ LEDs ❑ Power supply Connectors Table 2 lists and defines the type of connectors available and their function.
Product Description Table 3 LEDs Color LINK/ACTIVITY Green LED Status Description On indicates a valid physical link on the port. Blinking indicates data is being transmitted. Off means no link. 100M Green Off means the bandwidth is 10 Mbps. On means the bandwidth is 100 Mbps. FDX (FULL-DUPLEX) Green On indicates full-duplex transmission mode. Off indicates half-duplex transmission mode. POWER Green Off means there is no power to the switch. On means there is power to the switch.
AT-FS708 and AT-FS708E Switches Installation Guide Power Supply The AT-FS708 uses a 40W universal internal switching power supply with 100 to 120 VAC, or 200 to 240 VAC, 50/60 Hz input rating. Allied Telesyn ships power cords with the units to the U.S., Continental Europe, and the U.K. The AT-FS708E uses an external power adapter. Required Voltage The switches require input of 100 to 230 VAC. Maximum power consumption is 50W maximum.
Chapter 2 Installation Before you Proceed Before installing the switch, make sure you read “Electrical Safety and Installation Requirements” on page iii.
Installation Site Requirements Make sure you observe the following site requirements: ❑ Make sure you are placing the switch in a dust-free and moisture-free environment. ❑ Do not block ventilation openings on the unit. Allow at least 10 cm (4 in) of space at the front and back of the unit for ventilation. ❑ Make sure that the switch’s power is accessible and cables can be connected easily.
AT-FS708 and AT-FS708E Switches Installation Guide Note The switch performs a self-diagnostic test upon power on, and takes about 20 seconds to complete. 5. Make sure the Power LED on the front panel lights green. 6. Attach the data cables and observe normal operation as indicated by the port LEDs. Use only one Port 8, either Port 8 MDI or Port 8 MDI-X. Rackmount Installation Rackmount installation applies to the AT-FS708 only. You will need a Phillips screwdriver for this installation.
Installation Configuration The following sections discuss standalone, cascade and uplink configurations. Standalone Configuration Figure 4 shows the switch connected to end stations and a server. The basic physical connection for this configuration requires connecting one of the switch’s ports to the adapter card of an end station.
AT-FS708 and AT-FS708E Switches Installation Guide Cascade Configuration Cascading means that two switches can be connected together using any of the switch ports provided you maintain the same medium type. Two switches can be cascaded to support multiple network port connections. Cable length to the nodes must follow the 100Base-TX cabling specifications. To cascade installed switches, do the following: Note When cascading switches, you must use the same medium type from port to port. 1.
Installation CORPORATE BACKBONE AT-FS708 Switch Hub Hub Sales AT-FS708 Switch Hub Engineering AT-FS708 Switch Finance FORMULA 8200 Switch MIS SNMP Station Figure 6 Switches as Uplink to the Backbone 12
Chapter 3 Troubleshooting This chapter describes the procedures to test and troubleshoot the switches. Connectivity Testing In the following procedure, you will test each port for a valid connection and to confirm the correct operation of the network. 1. Start with Ports 1 and 2. Connect these two ports of a single switch to two nodes or workstations and turn on the switch power. 2.
Troubleshooting Problem Solving Is the unit receiving power? Check the Power LED on the front of the switch. This green LED should be lit. Note The switch performs a self-diagnostic test upon power on, and takes about 20 seconds to complete. If the Power LED is not on, check both ends of the power cord or adapter. Make sure the power cord or adapter is plugged into a functioning wall outlet and that it is properly inserted into the switch’s connector on the back of the unit.
AT-FS708 and AT-FS708E Switches Installation Guide 4. Problem 4: There is data loss between the switch and one of the connected network nodes. ❑ Solution 4: — Make sure that the distance between the switch and the connected network device is no greater than 100 m (328 ft). — Make sure you are using Category 5 cable.
Appendix A Switch Specifications Physical Characteristics Chassis Dimensions: AT-FS708 9.81 in (W) x 4.5 in (D) x 1.5 in (H) 249 mm (W) x 114 mm (D) x 38 mm (H) AT-FS708E 7.75 in (W) x 4.56 in (D) x 1.44 in (H) 197 mm (W) x 116 mm (D) x 37 mm (H) Weight: AT-FS708 3.65 lbs (1.9 kg) AT-FS708E 1.4 lbs (0.
Switch Specifications Cabling Specifications 10Base-T: STP/UTP Category 3,4,5 100 ohm impedance 100Base-TX: STP/UTP Category 5 wiring, 100 ohm impedance 100 m (328 ft) between switch and network node. Electrical Specifications AT-FS708 Internal Power: Internal universal power supply with 100 to 240 VAC, 50/60 Hz, 0.3 A input. AT-FS708E External Power: External power adaper provides 13-19 UDC, 800 mA maximum. UTP (RJ45) Connector Figure 7 shows an RJ45 connector.
AT-FS708 and AT-FS708E Switches Installation Guide Network Specifications Table 5 provides an overview of IEEE 802.3 and 802.3u specifications for 10Base-T and 100Base-TX network configurations using shielded twisted-pair wiring. Table 5 IEEE 802.3 and 802.
Switch Specifications 100Base-TX Connector Pinouts Straight-through Cable 1 TX+ 2 TX3 RX+ TX+ 1 TX- 2 RX+ 3 6 RX- RX- 6 1 TX+ 2 TX3 RX+ TX+ 1 TX- 2 RX+ 3 6 RX- RX- 6 Crossover Cable 20
Appendix B Technical Support Fax Order Name _________________________________________________________________________ Company______________________________________________________________________ Address_______________________________________________________________________ City ___________________________State/Province___________________________________ Zip/Postal Code ______________________ Country___________________________________ Phone __________________________________ Fax___________________________
Appendix C AT-FS708 and AT-FS708E Switches Installation Feedback Please tell us what additional information you would like to see discussed in the guide. If there are topics you would like information on that were not covered in the guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn International Corp. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of the guide.
Appendix D Where To Find Us For Technical Support or Service Location Phone Fax Americas United States, Canada, Mexico, Central America, South America 1 (800) 428-4835 1 (918) 628-3222 Asia Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India (+65) 3815-613 (+65) 3833-830 Australia Australia, New Zealand (+61) 2-943-5111 (+61) 2-9438-4966 France France, Belgium, Luxembourg, The Netherlands, Middle East, Africa (+33) 1-60-92-15-32 (+33) 1-69-28-37-49 Germany Germ