AT-MC104XL AT-MC104LH Fast Ethernet Media Converters Installation Guide PN 613-10781-00 Rev C
Copyright 1999 Allied Telesyn International, Corp. 960 Stewart Drive Suite B, Sunnyvale CA 94086 USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesyn International Corp.
Safety Warnings Standards: This product meets the following standards U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Table of Contents Safety Warnings ............................................................................................ iii AT-MC104XL and AT-MC104LH Media Converters ............................... 1 Key Features................................................................................................ 2 LEDs ............................................................................................................ 2 NML/LNK TST Switch..........................................................
AT-MC104XL and AT-MC104LH Media Converters The AT-MC104XL and AT-MC104LH (Long Haul) are 100Base-FX media converters that convert 100Base-FX multimode (MMF) to 100Base-FX single mode (SMF). The converters feature SC connectors and come with an external 12 V DC power adapter to supply power. See Figure 1 and Figure 2.
Key Features The converters have the following key features: ❑ LEDs for unit and port status ❑ NML/LNK TST (Normal/Link Test) switch ❑ Full duplex transparent operation ❑ MissingLink feature provides link fault detection on the 100Base-FX segments ❑ Low power consumption ❑ Minimal delay for optimum performance ❑ Fast data conversion ❑ Polyswitched fuse protection ❑ External AC-DC Power Adapter ❑ Standard size for use with AT-MCR12 rack-mount chassis.
AT-MC104XL and AT-MC104LH Installation Guide NML/LNK TST Switch The NML/LNK TST (Normal/Link Test) switch, located on the front panel, establishes a fiber/fiber link in the test position. The default position of the switch is IN, which is the normal (NML) operating mode and enables the MissingLink feature. With the switch in the OUT or Link Test mode (LNK TST) position, the MissingLink feature is disabled and the optical transmitter TX is forced on.
Package Contents ❑ AT-MC104XL or AT-MC104LH Media Converter ❑ Four Protective Feet (for standalone use only) ❑ External AC-DC power Adapter ❑ This Installation Guide ❑ Warranty Card Contact your sales representative if any items are missing or damaged. Installing the Media Converter as a Standalone Warning Do not stare into the laser beam when installing the media converters.
AT-MC104XL and AT-MC104LH Installation Guide 4. Verify that the PWR LED lights green. 5. Set the NML/LNK TST switch to LNK TST (OUT position). 6. Remove the dust cap from the fiber optic connectors. 7. Plug the SMF cable into the connector. See Table 3 on page 9 for cabling specifications. Note End stations used with the media converter must operate in the same duplex mode (either both full-duplex or both half-duplex). 8. Connect the other end of the fiber cable to the desired end station.
PWR 6 TX PWR RX TX TX RX LNK REC MDI LNK REC MDI 100Base-FX MDI-X RX 100Base-FX MDI-X PWR RX MDI MDI-X PWR RX 100Base-TX PWR RX LNK PWR RX LNK PWR RX LNK PWR RX LNK LNK REC MDI 100Base-FX MDI-X PWR RX LNK REC MDI 100Base-FX MDI-X Figure 5 AT-MCR12 Rack-mount Chassis PWR RX RX 100Base-TX REC LNK 100Base-TX LNK MDI-X LNK MDI REC 100Base-FX MC102 FAST ETHERNET MEDIA CONVERTER TX LNK REC MDI-X LNK MDI REC 100Base-TX REC 100Base-FX LNK REC MC
AT-MC104XL and AT-MC104LH Installation Guide Configurations Figure 6 shows two typical network configurations of the AT-MC104XL Media Converter. 10/100Base-TX Switch AT-MC103XL 100 meters AT-MC104XL 15 Kilometers/ 49,213 ft or 9.3 mi 2 Kilometers/ 6,562 ft 10/100Base-TX/FX Switch 10/100Base-TX/FX Switch AT-MC104XL 2 Kilometers/ 6,562 ft AT-MC104XL 15 Kilometers/ 49,213 ft or 9.
Troubleshooting To troubleshoot your media converter, perform the following: 1. Set the unit in the Link Test mode. 2. End stations used with the media converter must operate in the same duplex mode (either both full-duplex or both half-duplex). 3. Verify that proper fiber cable is being used (See Table 3 on page 9). 4. Verify that the near end node transmitter (TX) is connected to the far end node receiver (RX) and vice versa on each fiber segment.
AT-MC104XL and AT-MC104LH Installation Guide Recommended Cables and Cable Specifications Table 3 lists the IEEE 802.3u cabling specifications. Refer to this table for cabling recommendations. Table 3 IEEE 802.3u Cabling Specifications for AT-MC104XL and AT-MC104LH 100Base-FX Media 1310 nm Multimode fiber (MMF), 50/125 micron 1310 nm Multimode fiber (MMF), 62.
Technical Support and Service You can contact the dealer where you purchased your product for local assistance. If local help is unable to resolve your problem, Allied Telesyn offers technical support via fax or telephone. Refer to Appendix D, for technical support telephone and fax numbers or www.alliedtelesyn.com for current world-wide office locations. Warranty The AT-MC104XL and AT-MC104LH media converters have a lifetime warranty. The power adapter has a one year warranty.
Appendix A Electrical Safety and Installation Requirements STANDARDS: This product meets the following standards U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
NORMEN: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. !1 Hochfrequenzstörung !2 WARNUNG: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen. !3 EN55022 Klasse A Störsicherheit EN50082-1 1997 Elektrische Sicherheit TUV-EN60950, UL1950, CSA 950 Laser EN60825 Warnung Laserprodukt der Klasse 1. !4 Warnung Nicht direkt in den Strahl blicken.
AT-MC104XL and AT-MC104LH Installation Guide EISEN: Dit product voldoet aan de volgende eisen. !1 RFI Emissie !2 WAARSCHUWING: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen. !3 EN55022 Klasse A Immuniteit EN50082-1 1997 Electrische Veiligheid TUV-EN60950, UL1950, CSA 950 Laser EN60825 Waarshuwing Klasse-1 laser produkt. !4 Waarchuwing Neit in de straal staren.
STANDARDIT: Tämä tuote on seuraavien standardien mukainen. !1 Radioaaltojen häirintä !2 VAROITUS: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin. !3 EN55022 Luokka A Kestävyys EN50082-1 1997 Sähköturvallisuus TUV-EN60950, UL1950, CSA 950 Laser EN60825 Varoitus Luokan 1 Lasertuote. !4 Variotus Älä katso säteeseen.
AT-MC104XL and AT-MC104LH Installation Guide SIKKERHETSNORMER: Dette produktet tilfredsstiller følgende sikkerhetsnormer. !1 RFI stråling !2 ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler. !3 EN55022 Klasse A Immunitet EN50082-1 1997 Elektrisk sikkerhet TUV-EN60950, UL1950, CSA 950 Laser EN60825 ADVARSEL Laserprodukt av klasse 1. !4 ADVARSAL Stirr ikke på strålen.
ESTÁNDARES: Este producto cumple con los siguientes estándares. !1 Emisión RFI !2 ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto. !3 EN55022 Clase A Inmunidad EN50082-1 1997 Seguridad eléctrica TUV-EN60950, UL1950, CSA 950 Laser EN60825 ¡ADVERTENCIA! Producto láser Clase 1. !4 ¡ADVERTENCIA! No mirat fijamente el haz.
Appendix B AT-MC104XL and AT-MC104LH Installation Guide Feedback Please tell us what additional information you would like to see discussed in this guide. If there are topics you would like information on that were not covered in this guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of this guide.
Appendix C Technical Support Fax Order Name _________________________________________________________________ Company ______________________________________________________________ Address _______________________________________________________________ City______________________ State/Province_______________________________ Zip/Postal Code ________________ Country_______________________________ Phone ______________________________ Fax_______________________________ Incident Summary Model number of Allied
Appendix D Where To Find Us For Technical Support or Service Location Phone Fax Americas United States, Canada, Mexico, Central America, South America 1 (800) 428-4835 1 (503) 639-3946 Asia Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India, Hong Kong (+65) 3815-612 (+65) 3833-830 Australia Australia, New Zealand 1 (800) 000-880 (+61) 2-9438-4966 France France, Belgium, Luxembourg, The Netherlands, Middle East, Africa (+33) 1-60-92-15-25 (+33) 1-69-28-37-49 Ge